FACTORS DETERMINING PULMONARY DEPOSITION OF AEROSOLIZED PENTAMIDINE IN PATIENTS WITH HUMAN-IMMUNODEFICIENCY-VIRUS INFECTION

被引:92
作者
SMALDONE, GC [1 ]
FUHRER, J [1 ]
STEIGBIGEL, RT [1 ]
MCPECK, M [1 ]
机构
[1] SUNY STONY BROOK,DEPT MED,DIV INFECT DIS,STONY BROOK,NY 11794
来源
AMERICAN REVIEW OF RESPIRATORY DISEASE | 1991年 / 143卷 / 04期
关键词
D O I
10.1164/ajrccm/143.4_Pt_1.727
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Although aerosolized pentamidine (AP) has recently been approved for prophylaxis and is undergoing clinical trials for treatment of pneumocystis, pneumonia (PCP), factors important in the deposition of AP have not been described. Using radioaerosol techniques, deposition was measured in 22 patients receiving AP for prophylaxis or treatment of PCP. In all patients total and regional deposition of pentamidine, breathing pattern, pulmonary function (PFT), regional ventilation, and type of nebulizer were analyzed. Bronchoalveolar lavage (BAL) was performed 24 h after inhalation to assess the relationship between pentamidine levels in BAL fluid and measured aerosol deposition. The nebulizers tested were the Marquest Respirgard(R) II and the Cadema AeroTech(R) II, both previously characterized in our laboratory. The aerosol particles consist of water droplets containing dissolved pentamidine and technetium 99m bound to albumin. Analysis of particles sampled during inhalation via cascade impaction confirmed a close relationship between radioactivity in the droplets and the concentration of pentamidine as measured by HPLC (r = 0.971, p < 0.0001; n = 18). Deposition was measured by capturing inhaled and exhaled particles on absolute filters and measuring radioactivity. This technique allows the determination of the deposition fraction (DF, the fraction of the amount inhaled that is deposited), which provides information on factors strictly related to the patient. To confirm the filter measurements, pentamidine deposition was also measured by gamma camera. The camera measurement was possible because each patient's thoracic attenuation of radioactivity was determined by a quantitative perfusion scan (mg pentamidine deposited via both techniques, r = 0.949, p < 0.0001; n = 26). Regional lung volume and ventilation were determined by xenon 133 equilibrium scan and washout. Pentamidine deposition varied markedly between patients, but BAL levels of pentamidine significantly correlated with measured deposition (r = 0.819, p < 0.01; n = 9). DF averaged 0.621 +/- 0.027 (SEM) and did not correlate with any measured lung parameter, including breathing pattern and PFT. Regional deposition did not correlate with regional ventilation. The major factor influencing pentamidine deposition was aerosol delivery (mg deposited versus mg inhaled; r = 0.963, p < 0.0001; n = 26). The nebulizer was an important determinant of aerosol delivery, with the AeroTech delivering between 2.5 and 5 times more drug than the Respirgard. These observations are important in assessing treatment failure and cost of therapy.
引用
收藏
页码:727 / 737
页数:11
相关论文
共 28 条
[1]  
[Anonymous], J AEROSOL MED
[2]   AEROSOL PENTAMIDINE [J].
ARMSTRONG, D ;
BERNARD, E .
ANNALS OF INTERNAL MEDICINE, 1988, 109 (11) :852-854
[3]  
BENNETT WD, 1988, J APPL PHYSIOL, V64, P1554
[4]   HUMAN VARIATION IN THE PERIPHERAL AIR-SPACE DEPOSITION OF INHALED PARTICLES [J].
BENNETT, WD ;
SMALDONE, GC .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 62 (04) :1603-1610
[5]  
BRAIN JD, 1979, AM REV RESPIR DIS, V120, P1325
[6]  
CHUNG KF, 1988, EUR RESPIR J, P1890
[7]   CONCENTRATIONS OF AEROSOLIZED PENTAMIDINE IN BRONCHOALVEOLAR LAVAGE, SYSTEMIC ABSORPTION, AND EXCRETION [J].
CONTE, JE ;
GOLDEN, JA .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1988, 32 (10) :1490-1493
[8]   OUTPUT CHARACTERISTICS FROM 3 MEDICAL NEBULIZERS [J].
DAHLBACK, M ;
NERBRINK, O ;
ARBORELIUS, M ;
HANSSON, HC .
JOURNAL OF AEROSOL SCIENCE, 1986, 17 (03) :563-564
[9]   AEROSOL PENETRANCE - SENSITIVE INDEX OF PERIPHERAL AIRWAYS OBSTRUCTION [J].
DOLOVICH, MB ;
SANCHIS, J ;
ROSSMAN, C ;
NEWHOUSE, MT .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (03) :468-471
[10]  
GOLDEN JA, 1984, AM REV RESPIR DIS, V129, P491