DO SEMIQUANTITATIVE AMNIOTIC-FLUID INDEXES REFLECT ACTUAL VOLUME

被引:53
|
作者
CROOM, CS [1 ]
BANIAS, BB [1 ]
RAMOSSANTOS, E [1 ]
DEVOE, LD [1 ]
BEZHADIAN, A [1 ]
HIETT, AK [1 ]
机构
[1] MED COLL GEORGIA,DEPT OBSTET & GYNECOL,MATERNAL FETAL MED SECT,AUGUSTA,GA 30912
关键词
AMNIOTIC FLUID VOLUME; AMNIOTIC FLUID POCKET; AMNIOTIC FLUID INDEX; ULTRASONOGRAPHY;
D O I
10.1016/S0002-9378(12)80026-3
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: Our objective was to determine how well semiquantitative ultrasonographic measures of amniotic fluid, i.e., maximal amniotic fluid vertical pocket and amniotic fluid index, reflect actual amniotic fluid volumes in 50 near-term patients whose amniotic fluid volume estimates were normal by visual inspection. STUDY DESIGN: Before amniocentesis for fetal lung maturity, each patient had visual amniotic fluid volume estimates, maximal amniotic fluid vertical pocket, and amniotic fluid index performed by the same examiner, and then each received intraamniotic injection of a 10% paraaminohippurate solution. Amniotic fluid volume was quantitated by spectrophotometric assay of paraaminohippurate concentration. Oligohydramnios and polyhydramnios were defined as <300 and >2000 ml, respectively. RESULTS: Quantitative amniotic fluid volume was positively related to both amniotic fluid index and maximal amniotic fluid vertical pocket (r = 0.75 and 0.60, respectively). True-positive rates for oligohydramnios (amniotic fluid index <5 cm or maximal amniotic fluid vertical pocket <2 cm) were 100% and 0%, respectively; false-positive rates with either method were 0%. True-positive rates for polyhydramnios (amniotic fluid index >20 cm and maximal amniotic fluid vertical pocket >8 cm) were 0%; false-positive rates were 16% and 24%, respectively. CONCLUSIONS: Amniotic fluid index appears to be slightly better than maximal amniotic fluid vertical pocket for reflecting actual amniotic fluid volume. Both indirect methods tend to overestimate actual amniotic fluid volume at the upper end of its extremes.
引用
收藏
页码:995 / 999
页数:5
相关论文
共 50 条
  • [2] Ultrasonographic assessment of amniotic fluid does not reflect actual amniotic fluid volume
    Chauhan, SP
    Magann, EF
    Morrison, JC
    Whitworth, NS
    Hendrix, NW
    Devoe, LD
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1997, 177 (02) : 291 - 296
  • [3] AMNIOTIC-FLUID INDEX - CORRELATION WITH AMNIOTIC-FLUID VOLUME
    HOSKINS, IA
    MCGOVERN, PG
    ORDORICA, SA
    FRIEDEN, FJ
    YOUNG, BK
    AMERICAN JOURNAL OF PERINATOLOGY, 1992, 9 (5-6) : 315 - 318
  • [4] DIRECT VOLUME MEASUREMENT AT MIDTRIMESTER AMNIOINFUSION IN RELATION TO ULTRASONOGRAPHIC INDEXES OF AMNIOTIC-FLUID VOLUME
    SEPULVEDA, W
    FLACK, NJ
    FISK, NM
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 170 (04) : 1160 - 1163
  • [5] AMNIOTIC-FLUID VOLUME DETERMINATION
    ROSS, MG
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1993, 169 (02) : 435 - 436
  • [6] AMNIOTIC-FLUID VOLUME STUDIES
    HASWELL, GL
    MORRIS, JA
    OBSTETRICS AND GYNECOLOGY, 1973, 42 (05): : 725 - 732
  • [7] AMNIOTIC-FLUID VOLUME STUDIES
    MORRIS, JA
    HASWELL, GL
    OBSTETRICS AND GYNECOLOGY, 1972, 39 (04): : 626 - &
  • [8] AMNIOTIC-FLUID VOLUME ASSESSMENT
    DILDY, GA
    MOISE, KJ
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1995, 172 (01) : 238 - 239
  • [9] AMNIOTIC PRESSURE IN DISORDERS OF AMNIOTIC-FLUID VOLUME
    FISK, NM
    TANNIRANDORN, Y
    NICOLINI, U
    TALBERT, DG
    RODECK, CH
    OBSTETRICS AND GYNECOLOGY, 1990, 76 (02): : 210 - 214
  • [10] AMNIOTIC-FLUID PROSTAGLANDINS DO NOT REFLECT HUMAN-FETAL LUNG MATURATION
    CVETKOVIC, M
    YLIKORKALA, O
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1985, 92 (01): : 93 - 96