SIMULTANEOUS ONLINE DNA-SEQUENCING ON BOTH STRANDS WITH 2 FLUORESCENT DYES

被引:30
作者
WIEMANN, S
STEGEMANN, J
GROTHUES, D
BOSCH, A
ESTIVILL, X
SCHWAGER, C
ZIMMERMANN, J
VOSS, H
ANSORGE, W
机构
[1] EUROPEAN MOLEC BIOL LAB,D-69117 HEIDELBERG,GERMANY
[2] HOSP DURAN & REYNALS,INST REC ONCOL,DEPT MOLEC GENET,BARCELONA,SPAIN
关键词
D O I
10.1006/abio.1995.1015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe an automated DNA-sequencing technique which allows both the simultaneous sequencing from the two strands of double-stranded templates and the subsequent detection of the sequencing products online and in parallel. The technique is based on hardware technology also used in the ALF DNA sequencer (Pharmacia, Uppsala). A helium-neon laser was mounted into the sequencing device additionally to the standard argon laser. Two different primers, labeled with either fluorescein or Texas red, are used in a single sequencing reaction resulting in an output of two sequences. Both sequencing products are then analyzed on-line in the same lanes of a gel. This technique is especially useful for the complete sequencing of DNA fragments up to 1 kb. High accuracy sequencing of PCR products in double-stranded form can now be accomplished in only one sequencing reaction. (C) 1995 Academic Press, Inc.
引用
收藏
页码:117 / 121
页数:5
相关论文
共 10 条
[1]   A NONRADIOACTIVE AUTOMATED-METHOD FOR DNA-SEQUENCE DETERMINATION [J].
ANSORGE, W ;
SPROAT, BS ;
STEGEMANN, J ;
SCHWAGER, C .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1986, 13 (06) :315-323
[2]   AUTOMATED DNA SEQUENCING - ULTRASENSITIVE DETECTION OF FLUORESCENT BANDS DURING ELECTROPHORESIS [J].
ANSORGE, W ;
SPROAT, B ;
STEGEMANN, J ;
SCHWAGER, C ;
ZENKE, M .
NUCLEIC ACIDS RESEARCH, 1987, 15 (11) :4593-4602
[3]   2 DINUCLEOTIDE REPEAT POLYMORPHISMS AT 21Q22.3 (D21S416 AND D21S1235) [J].
BOSCH, A ;
WIEMANN, S ;
GUIMERA, J ;
ANSORGE, W ;
PATTERSON, D ;
ESTIVILL, X .
HUMAN MOLECULAR GENETICS, 1993, 2 (10) :1744-1744
[4]   MULTIPLEX DNA SEQUENCING [J].
CHURCH, GM ;
KIEFFERHIGGINS, S .
SCIENCE, 1988, 240 (4849) :185-188
[5]   DNA SEQUENCING WITH CHAIN-TERMINATING INHIBITORS [J].
SANGER, F ;
NICKLEN, S ;
COULSON, AR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1977, 74 (12) :5463-5467
[6]   FLUORESCENCE DETECTION IN AUTOMATED DNA-SEQUENCE ANALYSIS [J].
SMITH, LM ;
SANDERS, JZ ;
KAISER, RJ ;
HUGHES, P ;
DODD, C ;
CONNELL, CR ;
HEINER, C ;
KENT, SBH ;
HOOD, LE .
NATURE, 1986, 321 (6071) :674-679
[7]   TEXAS RED, A HYDROPHILIC, RED-EMITTING FLUOROPHORE FOR USE WITH FLUORESCEIN IN DUAL PARAMETER FLOW MICRO-FLUOROMETRIC AND FLUORESCENCE MICROSCOPIC STUDIES [J].
TITUS, JA ;
HAUGLAND, R ;
SHARROW, SO ;
SEGAL, DM .
JOURNAL OF IMMUNOLOGICAL METHODS, 1982, 50 (02) :193-204
[8]  
Voss H., 1992, Methods in Molecular and Cellular Biology, V3, P153
[9]  
VOSS H, 1992, Methods in Molecular and Cellular Biology, V3, P30
[10]  
ZIMMERMANN J, 1992, NUCLEIC ACIDS RES, V18, P1067