Comparison of the Coaxial Circle Circuit with the Conventional Circle Circuit

被引:0
|
作者
Mizrak, Ayse [1 ]
Bilgi, Murat [1 ]
Koruk, Senem [1 ]
Ganidagli, Suleyman [1 ]
Karatas, Erkan [2 ]
Oner, Unsal [1 ]
Gul, Rauf [1 ]
Sahin, Levent [1 ]
机构
[1] Gaziantep Univ, Fac Med, Dept Anesthesiol & Reanimat, Gaziantep, Turkey
[2] Gaziantep Univ, Fac Med, Dept Ear Nose & Throat ENT, Gaziantep, Turkey
来源
EURASIAN JOURNAL OF MEDICINE | 2011年 / 43卷 / 02期
关键词
Coaxial circle system; Standard circle system; Tympanomastoidectomy; Pulmonary function tests; Saccharin clearance test;
D O I
10.5152/eajm.2011.21
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The coaxial circle system helps prevent heat loss during surgery, and it also acts as a humidifier. This study aimed to compare the coaxial breathing system and the conventional system in their ability to warm and moisturize inhaled gases, and we also analyzed lung function protection and saccharin clearance time in patients who underwent tympanomastoidectomy (TMT) with the aid of these two systems. Materials and Methods: Forty adult patients of ASA physical status I-II were scheduled for elective TMT. A standard volume-dependent ventilator setting was used to establish normocapnia. The coaxial circle system was used in the treated group (n=20), whereas the conventional circuit system was used in the control group (n=20). Saccharin clearance, VC (vital capacity), FRC (functional residual capacity), FEV 1 (forced expiratory volume in 1 second), airway pressure, relative humidity and temperature of inspired gas, body temperature and adverse and hemodynamic effects were measured at different perioperative periods. Results: The relative humidity (mg H2O Lt - 1) of inspired gas in the treated group was higher than in the control group at 5, 15, 30, 45, 60 and 90 minutes after anesthesia induction. The temperature of inspired gas (Centigrade) in the treated group was higher than in the control group (p<0.05) after 5, 10, 15, 30, 45, and 90 minutes of anesthesia. Postoperative saccharin clearance time was lower than before the operation in the treated group (p<0.05). Postoperative FRC was lower than preoperative FRC in the study and control groups (p<0.05). ] Conclusion: The coaxial circle system decreased postoperative saccharin clearance time and increased postoperative FRC, relative humidity and the temperature of inspired fresh gas, without any adverse perioperative effects in patients who underwent TMT.
引用
收藏
页码:92 / 98
页数:7
相关论文
共 50 条
  • [41] MODELING THE HEART BEAT, CIRCLE OF WILLIS AND RELATED CEREBRAL STENOSIS USING AN EQUIVALENT ELECTRONIC CIRCUIT
    Sadraie, S. H.
    Abdi, M.
    Navidbakhsh, M.
    Hassani, K.
    Kaka, G. R.
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2014, 26 (05):
  • [42] REDUCTION OF FRESH GAS-FLOW REQUIREMENTS BY A CIRCLE-MODIFIED BAIN BREATHING CIRCUIT
    VALDRIGHI, JB
    NANCE, PN
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (01): : 49 - 55
  • [43] Social Comparison and the 'Circle of Objectification'
    Lindner, Danielle
    Tantleff-Dunn, Stacey
    Jentsch, Florian
    SEX ROLES, 2012, 67 (3-4) : 222 - 235
  • [44] Social Comparison and the ‘Circle of Objectification’
    Danielle Lindner
    Stacey Tantleff-Dunn
    Florian Jentsch
    Sex Roles, 2012, 67 : 222 - 235
  • [45] ALTERNATIVE MOUNT FOR BAIN COAXIAL CIRCUIT
    FARRAR, MD
    ANAESTHESIA, 1977, 32 (09) : 918 - 918
  • [46] CALCULATION OF Q OF A COAXIAL RESONANT CIRCUIT
    ORLOV, SI
    TELECOMMUNICATIONS AND RADIO ENGINEER-USSR, 1968, (01): : 65 - &
  • [47] Teaching circuit analysis in the studio format: A comparison with conventional instruction
    Carlson, AB
    Jennings, WC
    Schoch, PM
    28TH ANNUAL FRONTIERS IN EDUCATION CONFERENCE - CONFERENCE PROCEEDINGS, VOLS 1-3, 1998, : 967 - 970
  • [48] Comparison of a minimized perfusion circuit versus conventional cardiopulmonary bypass
    Gasparovic, Hrvoje
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (06) : 1083 - 1083
  • [49] COAXIAL BREATHING CIRCUIT AND SCAVENGING VALVE
    HENVILLE, JD
    ADAMS, AP
    ANAESTHESIA, 1976, 31 (02) : 257 - 258
  • [50] Circle systems with a coaxial inspiratory limb - Investigation with a lung model
    Cook, LB
    Chakrabarti, MK
    ANAESTHESIA, 1996, 51 (03) : 247 - 254