Enhancement of Fluorescent Properties and Electrochemical Reduction of Coumarin Derivatives

被引:0
作者
Chun, Hyun Ja [1 ,2 ]
Kim, Sung Hyun
Jung, Eun Joo
Lee, Hye Suk [3 ,4 ]
Kim, Il Kwang [1 ,2 ]
机构
[1] Wonkwang Univ, Coll Nat Sci, Dept Chem, Iksan 570749, South Korea
[2] Wonkwang Univ, Inst Basic Nat Sci, Iksan 570749, South Korea
[3] Wonkwang Univ, Coll Pharm, Drug Metab & Bioanal Lab, Iksan 570749, South Korea
[4] Wonkwang Univ, Phytofermentat Res Ctr, Drug Metab & Bioanal Lab, Iksan 570749, South Korea
关键词
coumarin derivatives; differential pulse polarography; cyclic voltammetry; electrochemical reduction; fluorescence;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Studies on the electrochemical reduction of 7-acetoxy-4-bromomethyl-coumarin (ABMC), 7-acetoxymethyl coumarin (AMC), and coumarin in 0.1 M tetraethyl ammonium perchlorate acetonitrile solution were carried out with direct current, differential pulse polarography, cyclic voltammetry, and controlled potential coulometry. The electrochemical reduction of ABMC was proceeded through three irreversible steps coupled with the chemical reactions. The solution color was changed to yellow when the carbonyl group was reduced during second step and the color change was independent with bromo group of ABMC. Fluorescent intensity was highest when the electrochemical reduction was controlled at near the overpotential of supporting electrolyte (-2.3 volts).
引用
收藏
页码:89 / 95
页数:7
相关论文
共 25 条
[1]   STUDIES OF ADSORPTION PROCESSES IN THE ABSENCE OF ADDED ELECTROLYTE - PHASE-CHANGES IN COUMARIN ADSORBED AT CONVENTIONAL AND MICRO MERCURY-ELECTRODES [J].
BOND, AM ;
THOMAS, FG .
LANGMUIR, 1988, 4 (02) :341-345
[2]  
BRACE L, 1983, AM J MED TECHNOL, V49, P457
[3]  
CAPKA O, 1950, COLLECT CZECH CHEM C, V15, P965
[4]  
CARRAZON JMP, 1989, ANAL CHIM ACTA, V216, P231
[5]   DEVELOPMENT OF AN ANTIBODY-BASED AMPEROMETRIC BIOSENSOR TO STUDY THE REACTION OF 7-HYDROXYCOUMARIN WITH ITS SPECIFIC ANTIBODY [J].
DEMPSEY, E ;
OSULLIVAN, C ;
SMYTH, MR ;
EGAN, D ;
OKENNEDY, R ;
WANG, J .
ANALYST, 1993, 118 (04) :411-413
[6]   DIFFERENTIAL-PULSE VOLTAMMETRIC DETERMINATION OF 7-HYDROXYCOUMARIN IN HUMAN URINE [J].
DEMPSEY, E ;
OSULLIVAN, C ;
SMYTH, MR ;
EGAN, D ;
OKENNEDY, R ;
WANG, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (06) :443-446
[7]   ELECTROCHEMICAL REACTIONS .8. ASYMMETRIC INDUCTION DURING REDUCTION OF COUMARINS MODIFIED BY PRESENCE OF TERTIARY AMINES [J].
GOURLEY, RN ;
GRIMSHAW, J ;
MILLAR, PG .
JOURNAL OF THE CHEMICAL SOCIETY C-ORGANIC, 1970, (17) :2318-+
[8]   THE POLAROGRAPHIC REDUCTION OF SOME HETEROCYCLIC MOLECULES .2. COUMARIN AND CERTAIN DERIVATIVES THEREOF [J].
HARLE, AJ ;
LYONS, LE .
JOURNAL OF THE CHEMICAL SOCIETY, 1950, (JUN) :1575-1578
[9]  
HOGAN EC, 1967, FD COSMET TOXICOL, V5, P141
[10]   FLUORESCENCE PROPERTIES OF COUMARIN LASER-DYES IN AQUEOUS POLYMER MEDIA - CHROMOPHORE ISOLATION IN POLY(METHACRYLIC ACID) HYPERCOILS [J].
JONES, G ;
RAHMAN, MA .
JOURNAL OF PHYSICAL CHEMISTRY, 1994, 98 (49) :13028-13037