ISOTOPE RATIO MEASUREMENTS USING GLOW-DISCHARGE MASS-SPECTROMETRY

被引:19
作者
RICIPUTI, LR [1 ]
DUCKWORTH, DC [1 ]
BARSHICK, CM [1 ]
SMITH, DH [1 ]
机构
[1] OAK RIDGE NATL LAB,DIV CHEM & ANALYT SCI,OAK RIDGE,TN 37831
来源
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES | 1995年 / 146卷
关键词
GLOW DISCHARGE MASS SPECTROMETRY; ISOTOPE RATIOS;
D O I
10.1016/0168-1176(95)04203-W
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Glow discharge mass spectrometry (GDMS) has been evaluated for its ability to measure isotope ratios in solids. Isotope ratios were measured for B, Cu, Sr, Ag, Sb, Re and Pb in concentrations ranging from 15 ppm to pure metal. External precision of better than 0.03% has been achieved for isotope ratios measured using pure solid elemental samples; typical precision is better than 0.1% for elements present in concentrations greater than 0.5 wt.%. For elements present in concentrations of 10-20 ppm, precision was about 1%. Isotopic bias was < 1%, and day-to-day variations in isotopic bias for a single element are as large as variations in isotopic bias between different elements, suggesting that most isotopic bias is dominated by instrumental parameters. Values of isotope ratios show a dependence on the pressure of the Ar discharge gas, suggesting that improvements in sample geometry and discharge stability have the potential to allow GDMS to achieve even better precision in the measurement of isotope ratios.
引用
收藏
页码:55 / 64
页数:10
相关论文
共 50 条
  • [31] Layerwise analysis of vacuum copper-chromium condensates by glow-discharge mass spectrometry
    Kurochkin, V. D.
    POWDER METALLURGY AND METAL CERAMICS, 2006, 45 (7-8) : 387 - 394
  • [32] OPTIMIZATION OF QUANTITATIVE DEPTH PROFILING WITH GLOW-DISCHARGE MASS-SPECTROMETRY .1. OPTIMIZATION STUDIES ON CRATER SHAPE AND TIME DEPTH CONVERSION
    RAITH, A
    HUTTON, RC
    HUNEKE, JC
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (06) : 867 - &
  • [33] Measurement of isotope ratios of boron and silicon by glow discharge mass spectrometry using a small quantity of sample
    Itoh, S
    Hasegawa, R
    JOURNAL OF THE JAPAN INSTITUTE OF METALS, 1998, 62 (03) : 289 - 292
  • [34] COMPARATIVE-STUDY OF DETERMINATION OF MICRO-AMOUNTS OF BORON IN HIGH-PURITY MOLYBDENUM BY A SPECTROPHOTOMETRIC METHOD USING CURCUMIN, SPARK SOURCE-MASS SPECTROMETRY AND GLOW-DISCHARGE MASS-SPECTROMETRY
    SAITO, M
    HIROSE, F
    OKOCHI, H
    ANALYTICAL SCIENCES, 1995, 11 (04) : 695 - 697
  • [35] EFFECTS OF THE DISCHARGE-GAS FLOW-RATE ON THE RELATIVE SENSITIVITY FACTORS IN GLOW-DISCHARGE MASS-SPECTROMETRY WITH A GRIMM-TYPE ION-SOURCE
    TANAKA, T
    KUBOTA, T
    KAWAGUCHI, H
    ANALYTICAL SCIENCES, 1994, 10 (06) : 895 - 899
  • [36] Direct isotope analysis of Chernobyl microparticles using time-of-flight mass spectrometry with pulsed glow discharge
    Ganeev, Aleksander
    Gubal, Anna
    Korotetski, Boris
    Bogdanova, Oksana
    Burakov, Boris
    Titova, Anna
    Solovyev, Nikolay
    Ivanenko, Natalya
    Drobyshev, Evgenii
    Iakovleva, Evgenia
    Sillanpaa, Mika
    MICROCHEMICAL JOURNAL, 2017, 132 : 286 - 292
  • [37] Effect of hydrogen addition to the discharge gas in radio-frequency argon glow-discharge mass spectrometry for nonconducting samples
    Tanaka, T
    Matsuno, M
    Woo, JC
    Kawaguchi, H
    ANALYTICAL SCIENCES, 1996, 12 (04) : 591 - 595
  • [38] Sample-preparation method for the analysis of yttria-stabilized zirconia by glow-discharge mass spectrometry
    Itoh, S
    Nakajima, H
    Yamaguchi, H
    Kobayashi, T
    BUNSEKI KAGAKU, 2005, 54 (10) : 1015 - 1019
  • [39] Precision and accuracy in isotope ratio measurements by plasma source mass spectrometry
    Heumann, KG
    Gallus, SM
    Radlinger, G
    Vogl, J
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) : 1001 - 1008
  • [40] Round robin analysis of aluminium using glow discharge mass spectrometry
    Venzago, C
    Ohanessian-Pierrard, L
    Kasik, M
    Collisi, U
    Baude, S
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (03) : 189 - 193