ISOTOPE RATIO MEASUREMENTS USING GLOW-DISCHARGE MASS-SPECTROMETRY

被引:19
作者
RICIPUTI, LR [1 ]
DUCKWORTH, DC [1 ]
BARSHICK, CM [1 ]
SMITH, DH [1 ]
机构
[1] OAK RIDGE NATL LAB,DIV CHEM & ANALYT SCI,OAK RIDGE,TN 37831
来源
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES | 1995年 / 146卷
关键词
GLOW DISCHARGE MASS SPECTROMETRY; ISOTOPE RATIOS;
D O I
10.1016/0168-1176(95)04203-W
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Glow discharge mass spectrometry (GDMS) has been evaluated for its ability to measure isotope ratios in solids. Isotope ratios were measured for B, Cu, Sr, Ag, Sb, Re and Pb in concentrations ranging from 15 ppm to pure metal. External precision of better than 0.03% has been achieved for isotope ratios measured using pure solid elemental samples; typical precision is better than 0.1% for elements present in concentrations greater than 0.5 wt.%. For elements present in concentrations of 10-20 ppm, precision was about 1%. Isotopic bias was < 1%, and day-to-day variations in isotopic bias for a single element are as large as variations in isotopic bias between different elements, suggesting that most isotopic bias is dominated by instrumental parameters. Values of isotope ratios show a dependence on the pressure of the Ar discharge gas, suggesting that improvements in sample geometry and discharge stability have the potential to allow GDMS to achieve even better precision in the measurement of isotope ratios.
引用
收藏
页码:55 / 64
页数:10
相关论文
共 50 条
  • [11] SAMPLE PREPARATION OF HIGH-PURITY TITANIUM FOR ANALYSIS BY GLOW-DISCHARGE MASS-SPECTROMETRY
    FANG, DC
    SEEGOPAUL, P
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (06) : 959 - 964
  • [12] DETERMINATION OF TRACE AMOUNTS OF CARBON, NITROGEN AND OXYGEN IN STEEL BY GLOW-DISCHARGE MASS-SPECTROMETRY
    TANAKA, K
    ONO, A
    SAEKI, M
    KIKUCHI, O
    TAKAHARI, T
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1991, 77 (11): : 1843 - 1850
  • [13] ANALYSIS OF ALUMINUM-OXIDE POWDER BY GLOW-DISCHARGE MASS-SPECTROMETRY WITH LOW-MASS RESOLUTION
    WOO, JC
    JAKUBOWSKI, N
    STUEWER, D
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (06) : 881 - 889
  • [14] Analysis of magnesium alloys by glow-discharge mass spectrometry
    Itoh, S
    Yamaguchi, H
    Hobo, T
    Kobayashi, T
    BUNSEKI KAGAKU, 2004, 53 (06) : 569 - 574
  • [15] DETERMINATION OF TRACE-ELEMENTS IN HIGH-PURITY MOLYBDENUM BY GLOW-DISCHARGE MASS-SPECTROMETRY
    MIZOTA, T
    NAKAMURA, T
    IWASAKI, K
    BUNSEKI KAGAKU, 1992, 41 (09) : 425 - 431
  • [16] EVALUATION OF SECONDARY CATHODES FOR GLOW-DISCHARGE MASS-SPECTROMETRY ANALYSIS OF DIFFERENT NONCONDUCTING SAMPLE TYPES
    SCHELLES, W
    DEGENDT, S
    MULLER, V
    VANGRIEKEN, R
    APPLIED SPECTROSCOPY, 1995, 49 (07) : 939 - 944
  • [17] CRATER SHAPES IN GLOW-DISCHARGE MASS-SPECTROMETRY WITH A GRIMM-TYPE ION-SOURCE
    PAK, YN
    TANAKA, T
    KAWAGUCHI, H
    ANALYTICAL SCIENCES, 1993, 9 (01) : 137 - 139
  • [18] PERIODIC NATURE OF METAL-NOBLE GAS ADDUCT IONS IN GLOW-DISCHARGE MASS-SPECTROMETRY
    BARSHICK, CM
    SMITH, DH
    JOHNSON, E
    KING, FL
    BASTUG, T
    FRICKE, B
    APPLIED SPECTROSCOPY, 1995, 49 (07) : 885 - 889
  • [19] QUADRUPOLE VERSUS MAGNETIC-SECTOR GLOW-DISCHARGE MASS-SPECTROMETRY - COMPARISON OF QUANTITATIVE ANALYTICAL CAPABILITIES
    RAITH, A
    VIETH, W
    HUNEKE, JC
    HUTTON, RC
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (06) : 943 - 949
  • [20] ROUND-ROBIN TEST FOR PRECISION IN THE DETERMINATION OF IMPURITIES IN COPPER AND INDIUM BY GLOW-DISCHARGE MASS-SPECTROMETRY
    NAKAMURA, Y
    MAEDA, S
    NAGAI, I
    INOUE, H
    OHTAKI, M
    YAMAZAKI, M
    HOSOI, M
    SHINZAWA, K
    SAYAMA, Y
    KAWABATA, T
    BUNSEKI KAGAKU, 1991, 40 (12) : T209 - T215