THE VALIDITY OF DOPPLER-DERIVED SPECTRAL-ANALYSIS IN THE PRESENCE OF MULTIPLE STENOSES

被引:3
作者
LATINO, JM [1 ]
CHLEBOUN, JO [1 ]
机构
[1] UNIV PERTH, REPATRIAT GEN HOSP, DEPT SURG, NEDLANDS, WA 6009, AUSTRALIA
来源
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY | 1994年 / 64卷 / 05期
关键词
BENCHTOP MODEL; DOPPLER ULTRASOUND; PERIPHERAL VASCULAR DISEASE; SPECTRAL ANALYSIS; ULTRASONIC DOPPLER;
D O I
10.1111/j.1445-2197.1994.tb02223.x
中图分类号
R61 [外科手术学];
学科分类号
摘要
It has been suggested that mathematical analysis of ultrasonic Doppler spectral waveforms allows non-invasive quantification of arterial stenoses proximal to the Doppler probe. Less emphasis has been placed on the influence of distal stenoses or distance to the ultrasonic probe. A benchtop electromechanical model with multiple stenoses was constructed to evaluate the effects on spectral waveforms of variations in the severity of proximal and distal stenosis, length of stenoses, distance between stenoses, and distance between ultrasonic probe and stenoses. The following analytic indices, descriptive of spectral waveforms, were evaluated: pulsatility index, spectral broadening index, Laplace damping factor, mode frequency, mean frequency, arithmetic mean frequency, maximum envelope frequency and minimum envelope frequency. All these indices, except the mode frequency, were influenced by the degree of distal as well as proximal stenosis. They were also affected by the distance between the Doppler probe and the upstream and downstream stenoses. The length of stenoses did not influence the flow waveform. Of the model variables, the distal stenosis had the greatest influence on the calculated indices. However, none of the analytic techniques could detect a stenosis smaller than a 70% reduction in cross-sectional area. It was concluded that Doppler-derived spectral waveforms between sequential stenoses are inevitably influenced by events other than the degree of proximal stenosis alone. Therefore, ultrasonic spectral waveforms obtained at a single point of the arterial tree in patients with multisegment arterial disease should be interpreted with caution.
引用
收藏
页码:338 / 344
页数:7
相关论文
共 29 条
[1]   SOME FAILINGS OF PULSATILITY INDEX AND DAMPING FACTOR [J].
BAKER, AR ;
EVANS, DH ;
PRYTHERCH, DR ;
MORTON, DB ;
BENTLEY, S ;
ASHER, MJ ;
BELL, PRF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (11) :875-881
[2]  
BAKER JD, 1990, SURG CLIN N AM, V70, P31
[3]   ANALYSIS OF FEMORAL-ARTERY DOPPLER SIGNALS BY LAPLACE TRANSFORM DAMPING METHOD [J].
BAKER, JD ;
MACHLEDER, HI ;
SKIDMORE, R .
JOURNAL OF VASCULAR SURGERY, 1984, 1 (04) :520-524
[4]   TRANSFER-FUNCTION MODELING OF ARTERIES [J].
BROWN, JM ;
NAHORSKI, ZT ;
WOODCOCK, JP ;
MORRIS, SJ .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1978, 16 (02) :161-164
[5]   DETECTION OF EARLY ARTERIAL-DISEASE - A STUDY USING DOPPLER WAVEFORM ANALYSIS [J].
CAMPBELL, WB ;
SKIDMORE, R ;
WOODCOCK, JP ;
BAIRD, RN .
CARDIOVASCULAR RESEARCH, 1985, 19 (04) :206-211
[6]   AN INVITRO MODEL AND ITS APPLICATION FOR THE STUDY OF CAROTID DOPPLER SPECTRAL BROADENING [J].
DOUVILLE, Y ;
JOHNSTON, KW ;
KASSAM, M ;
ZUECH, P ;
COBBOLD, RSC ;
JARES, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1983, 9 (04) :347-356
[7]  
EVANS D H, 1981, Clinical Physics and Physiological Measurement, V2, P17, DOI 10.1088/0143-0815/2/1/004
[8]   THE RELATIONSHIP BETWEEN ULTRASONIC PULSATILITY INDEX AND PROXIMAL ARTERIAL-STENOSIS IN A CANINE MODEL [J].
EVANS, DH ;
BARRIE, WW ;
ASHER, MJ ;
BENTLEY, S ;
BELL, PRF .
CIRCULATION RESEARCH, 1980, 46 (04) :470-475
[9]   FEMORAL PULSATILITY INDEX IN THE EVALUATION OF AORTOILIAC OCCLUSIVE DISEASE [J].
FLANIGAN, DP ;
COLLINS, JT ;
GOODREAU, JJ ;
BURNHAM, SJ ;
YAO, JST .
JOURNAL OF SURGICAL RESEARCH, 1981, 31 (05) :392-399
[10]   QUANTITATIVE ULTRASONOGRAPHIC STUDIES OF LOWER-EXTREMITY FLOW VELOCITIES IN HEALTH AND DISEASE [J].
FRONEK, A ;
COEL, M ;
BERNSTEIN, EF .
CIRCULATION, 1976, 53 (06) :957-960