Validating the Spanish version of the Nursing Activities Score

被引:8
作者
Sanchez-Sanchez, M. M. [1 ]
Arias-Rivera, S. [1 ,2 ]
Fraile-Gamo, M. P. [1 ]
Thuissard-Vasallo, I. J. [3 ]
Frutos-Vivar, F. [1 ,2 ]
机构
[1] Hosp Univ Getafe, Serv Cuidados Intens, Madrid, Spain
[2] Inst Salud Carlos III, CIBER Enfermedades Resp, Madrid, Spain
[3] Univ Europea Madrid, Madrid, Spain
来源
ENFERMERIA INTENSIVA | 2015年 / 26卷 / 02期
关键词
Workloads; Psychometric properties; Validation; Critical care; Nursing Activities Score; Nine Equivalent of Nursing Man power Score;
D O I
10.1016/j.enfi.2015.02.003
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Introduction: Validating workload scores ensures that they are appropriate for the purpose for which they were developed. Objective: To validate the Nursing Activities Score (NAS) Spanish version. Methodology: Observational and prospective study. 1,045 patients who were admitted to a medical-surgical unit and a serious burns unit in 2006 were included. The nurse in charge assessed patient workloads by Nine Equivalent of Nursing Manpower use Score and NAS. To assess the internal consistency of the measurements of NAS, item-test correlations, Cronbach's alpha and Cronbach's alpha corrected by omitting each of the items were calculated. The intraobserver and interobserver reliability were assessed with the intraclass correlation coefficient by viewing recordings and Kappa (interobserver reliability) was estimated. For the analysis of internal validity, a factorial principal components analysis was performed. Convergent validity was assessed using the Spearman correlation coefficient values obtained from the Nine Equivalent of Nursing Manpower use Score and Spanish-NAS scales. Results: For internal consistency, 164 questionnaires were analysed and a Cronbach's alpha of 0.373 was calculated. The intraclass correlation coefficient for intraobserver reliability estimate was 0.837 (95% IC: 0.466-0.950) and 0.662 (95% IC: 0.033-0.882) for interobserver reliability. The estimated kappa was 0.371. For internal validity, exploratory factor analysis showed that the first item explained 58.9% of the variance of the questionnaire. For convergent validity 1006 questionnaires were included and a Spearman correlation coefficient of 0.746 was observed. Conclusions: The psychometric properties of Spanish-NAS are acceptable. (C) 2014 Elsevier Espana, S.L.U. and SEEIUC. All rights reserved.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 18 条
[1]  
Altman D.G., 1991, PRACTICAL STAT MED R
[2]   Transcultural adaptation into Spanish of the Nursing Activities Score [J].
Arias-Rivera, S. ;
Sanchez-Sanchez, M. M. ;
Fraile-Gamo, M. P. ;
Patino-Freire, S. ;
Pinto-Rodriguez, V ;
Conde-Alonso, M. P. ;
Ferguson, N. D. ;
Frutos-Vivar, F. .
ENFERMERIA INTENSIVA, 2013, 24 (01) :12-22
[3]  
Adell AB, 2006, ENFERM INTENSIV, V17, P67
[4]  
Bertoni A, 1996, EVALUACION NUEVOS SI
[5]  
Cullen D J, 1974, Crit Care Med, V2, P57, DOI 10.1097/00003246-197403000-00001
[6]  
Fleiss, 1986, DESIGN ANAL CLIN EXP
[7]   Usage analysis of the Nursing Activities Score in two Spanish ICUS [J].
Javier Carmona-Monge, Francisco ;
Uria Uranga, Ikerne ;
Garcia Gomez, Sonia ;
Quiros Herranz, Cristina ;
Bergaretxe Bengoetxea, Maitane ;
Etxabe Unanue, Goiatz ;
Iribarren Martin, Alazne ;
Echepetelecu Hernando, Maialen ;
Badiola Saralegui, Erika ;
Auzmendi Irazoqui, Miren .
REVISTA DA ESCOLA DE ENFERMAGEM DA USP, 2013, 47 (05) :1106-1113
[8]   Evaluation of the nursing workload through the nine equivalents for nursing manpower use scale and the nursing activities score: A prospective correlation study [J].
Javier Carmona-Monge, Francisco ;
Rollan Rodriguez, Gloria Ma ;
Quiros Herranz, Cristina ;
Garcia Gomez, Sonia ;
Marin-Morales, Dolores .
INTENSIVE AND CRITICAL CARE NURSING, 2013, 29 (04) :228-233
[9]   THERAPEUTIC INTERVENTION SCORING SYSTEM - UPDATE 1983 [J].
KEENE, AR ;
CULLEN, DJ .
CRITICAL CARE MEDICINE, 1983, 11 (01) :1-3
[10]   Nursing activities score [J].
Miranda, DR ;
Nap, R ;
de Rijk, A ;
Schaufeli, W ;
Lapichino, G .
CRITICAL CARE MEDICINE, 2003, 31 (02) :374-382