HOT-ELECTRON MICROCALORIMETERS FOR X-RAY AND PHONON DETECTION

被引:26
作者
NAHUM, M [1 ]
MARTINIS, JM [1 ]
CASTLES, S [1 ]
机构
[1] NASA,GODDARD SPACE FLIGHT CTR,GREENBELT,MD 20771
关键词
D O I
10.1007/BF00693504
中图分类号
O59 [应用物理学];
学科分类号
摘要
We propose a novel hot-electron microcalorimeter for measurements of x-rays or phonons produced by the interaction of a high energy particle with the underlying substrate. This type of detector uses a normal metal film to absorb the incoming excitation which subsequently heats the electrons above the lattice temperature. The temperature of the electrons is measured from the current - voltage characteristics of a superconductor-insulator-normal metal tunnel junction, where part of the absorber forms the normal electrode. We present simple calculations of the energy sensitivity of the junction and of the ultimate performance of x-ray and phonon detectors. We also present preliminary measurements of prototype devices which were used to test the basic detector physics.
引用
收藏
页码:733 / 738
页数:6
相关论文
共 10 条
  • [1] ANDREEV AF, 1964, ZH EKSP TEOR FIZ, V19, P1228
  • [2] Grannan S. M., 1993, PHONON SCATTERING CO, VVII, P500
  • [3] QUASIPARTICLE TRAPPING IN A SUPERCONDUCTIVE DETECTOR SYSTEM EXHIBITING HIGH-ENERGY AND POSITION RESOLUTION
    KRAUS, H
    VONFEILITZSCH, F
    JOCHUM, J
    MOSSBAUER, RL
    PETERREINS, T
    PROBST, F
    [J]. PHYSICS LETTERS B, 1989, 231 (1-2) : 195 - 202
  • [4] THE DETECTIVITY OF CRYOGENIC BOLOMETERS
    LOW, FJ
    HOFFMAN, AR
    [J]. APPLIED OPTICS, 1963, 2 (06): : 649 - 650
  • [5] MEARS CA, UNPUB APPL PHYS LETT
  • [6] NAHUM M, UNPUB APPL PHYS LETT
  • [7] Solymar L, 1972, SUPERCONDUCTIVE TUNN
  • [8] STODOLSKY L, 1991, PHYS TODAY AUG, P24
  • [9] WELLSTOOD FC, 1985, THESIS U CALIFORNIA
  • [10] TWO-STAGE INTEGRATED SQUID AMPLIFIER WITH SERIES ARRAY OUTPUT
    Welty, Richard P.
    Martinis, John M.
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1993, 3 (01) : 2605 - 2608