Comparison of Quality of Life between Patients Undergoing Chronic Hemodialysis with Reusable Dialyzer and Single-Use Dialyzer: A Retrospective Cohort Study

被引:0
|
作者
Bawazier, Lucky A. [1 ]
Suhardjono [1 ]
机构
[1] Univ Indonesia, Dept Internal Med, Fac Med, Cipto Mangunkusumo Hosp, Jakarta, Indonesia
关键词
kidney disease quality of life; hemodialysis; reusable dialyzer; single-use dialyzer;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: in Indonesia, majority of hemodialysis centers use reusable dialyzer for cost efficiency reason. Currently, there is no available data regarding the quality of life of the end stage-renal disease patient 'who use reusable dialyzer measured by a standardized questionnaire, as it was stated that at molecular level, reusable dialyzer could worsen leukocyte activity and could affect patients' complaints and symptoms. Methods: this was a retrospective cohort study which involved 39 subjects. All subjects underwent hemodialysis at Cipto Mangunkusumo Hospital. The study was conducted in March -September 2017. All subjects had experienced two kinds of dialyzers, the reusable dialyzers (before 2015) and the single-use dialyzers (after 2015). Of all patients, 19 patients did not know the change of dialyzers. Subjects were interviewed with Kidney Disease Quality of Life-Short Form 36 questionnaire. Results: in kidney disease component dimension, there was a significant mean difference between reusable group (68.74; SD 13.22) and single-use group (74.87; SD 13.54) (Wilcoxon test, p=0.01). The Physical Component Summary dimension, in reusable group was 63.65; SD 27.07 and in single-use group was 69.38; SD 23.07 (Wilcoxon test, p=0.217). The Mental Component Summary dimension, in reusable group was 71.78; SD 21.54 and in single-use group was75.27; SD 22.30 (Wilcoxon test, p=0.127). Bivariate analysis and further analysis showed significant association between income less than 5 million rupiah and low quality of life (p=0.048). Conclusion: the reusable dialyzer membrane lowers the ESRD patients' quality of lift influenced by another factor such as low income.
引用
收藏
页码:222 / 229
页数:8
相关论文
共 50 条
  • [1] Comparison the effect of high flux and low flux dialyzer on quality of life in hemodialysis patients; a clinical trial
    Oshvandi, Khodayar
    Safari, Mehri
    Gholyaf, Mahmood
    Moghim-Beygi, Abbas
    Shamsaei, Farshid
    Tamadon, Mohammadreza
    Alimohammadi, Neda
    JOURNAL OF RENAL INJURY PREVENTION, 2019, 8 (02): : 98 - 105
  • [2] The use of a low-flux hemo-dialyzer is associated with impaired platelet aggregation in patients undergoing chronic hemodialysis
    Chen, Ching-Yang
    Liou, Hung-Hsiang
    Chang, Min-Yu
    Wang, Hsi-Hao
    Lee, Yi-Che
    Ho, Li-Chun
    Lin, Tsun-Mei
    Hung, Shih-Yuan
    MEDICINE, 2022, 101 (43)
  • [3] Dialyzer Classification and Mortality in Hemodialysis Patients: A 3-Year Nationwide Cohort Study
    Abe, Masanori
    Masakane, Ikuto
    Wada, Atsushi
    Nakai, Shigeru
    Nitta, Kosaku
    Nakamoto, Hidetomo
    FRONTIERS IN MEDICINE, 2021, 8
  • [4] The Impact of Reusable Dialyzer Membrane on End-Stage Renal Disease Patients' Quality of Life: A Multicenter Study in Jakarta, Indonesia
    Bawazir, Lucky Aziza Abdullah
    Marbun, Maruhum Bonar
    Sianipar, Wicensius
    Luthariana, Lies
    SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2019, 30 (06) : 1285 - 1294
  • [5] Comparison of Adequacy of Dialysis between Single-use and Reused Hemodialyzers in Patients on Maintenance Hemodialysis
    Hamid, Amna
    Dhrolia, Murtaza F.
    Imtiaz, Salman
    Qureshi, Ruqayya
    Ahmad, Aasim
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2019, 29 (08): : 720 - 723
  • [6] Quality of life of patients bearing chronic kidney disease undergoing hemodialysis
    Marcal, Gabriela Roscosz
    Rego, Anderson da Silva
    Paiano, Marcelle
    Trindade Radovanovic, Cremilde Aparecida
    REVISTA DE PESQUISA-CUIDADO E FUNDAMENTAL ONLINE, 2019, 11 (04): : 908 - 913
  • [7] Comparison quality of life between chronic kidney disease patients on hemodialysis and renal transplantation
    Purnomo, N.
    Hamid, A. R. A. H.
    BJU INTERNATIONAL, 2016, 117 : 21 - 21
  • [8] To reuse or not to reuse? An economic evaluation of hemodialyzer reuse versus conventional single-use hemodialysis for chronic hemodialysis patients
    Manns, BJ
    Taub, K
    Richardson, RMA
    Donaldson, C
    INTERNATIONAL JOURNAL OF TECHNOLOGY ASSESSMENT IN HEALTH CARE, 2002, 18 (01) : 81 - 93
  • [9] Oral health-related quality of life in patients undergoing chronic hemodialysis
    Rodakowska, Ewa
    Wilczynska-Borawska, Magdalena
    Fryc, Justyna
    Baginska, Joanna
    Naumnik, Beata
    PATIENT PREFERENCE AND ADHERENCE, 2018, 12 : 955 - 961
  • [10] Association of cachexia with quality of life in patients with chronic kidney disease undergoing hemodialysis
    Yagi, Takuma
    Inoue, Tatsuro
    Ogawa, Masato
    Okamura, Masatsugu
    Shirado, Kengo
    Shirai, Nobuyuki
    Konishi, Shuji
    Koshiba, Takafumi
    Hirayama, Masao
    Isigaki, Yuichiro
    Heguri, Yasunori
    Tanimiya, Naoki
    Okada, Risa
    Iwata, Shuto
    Inoue, Shigeki
    RENAL REPLACEMENT THERAPY, 2025, 11 (01)