MR MONITORING OF FOCUSED ULTRASONIC SURGERY OF RENAL-CORTEX - EXPERIMENTAL AND SIMULATION STUDIES

被引:55
作者
HYNYNEN, K
DAMIANOU, CA
COLUCCI, V
UNGER, E
CLINE, HH
JOLESZ, FA
机构
[1] Department of Radiology, Division of MR Imaging, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, 02115
[2] Department of Radiology, University of Arizona Health Sciences Center, Tucson, Arizona
[3] General Electric Company, Schenectady, New York
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1995年 / 5卷 / 03期
关键词
HYPERTHERMIA; KIDNEY; SURGERY; MAGNETIC RESONANCE (MR) GUIDANCE; TEMPERATURE MONITORING; ULTRA-SOUND; THERAPEUTICS;
D O I
10.1002/jmri.1880050306
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to test the hypothesis that magnetic resonance (MR) imaging-guided and -monitored noninvasive ultrasonic surgery can be performed in highly perfused tissues from outside the body. A simulation study was performed to evaluate the optimal sonication parameters. An MR-compatible positioning device was then used to manipulate a focused ultrasound transducer in an MR imager, which was used to sonicate kidneys of five rabbits at various power levels and different durations. Temperature elevation during sonication was monitored with a T1-weighted spoiled gradient-echo sequence. The simulation study demonstrated that a sharply focused transducer and relatively short sonication times (30 seconds or less) are necessary to prevent damage to the overlying skin and muscle tissue, which have a much lower blood perfusion rate than kidney. The experiments showed that the imaging sequence was sensitive enough to show temperature elevation during sonication, thereby indicating the location of the beam focus. Histologic evaluations showed that kidney necrosis could be consistently induced without damage to overlying skin and muscle. The study demonstrated that highly perfused tissues such as the renal cortex can be coagulated from outside the body with focused ultrasound and that MR imaging can be used to guide and monitor this surgery.
引用
收藏
页码:259 / 266
页数:8
相关论文
共 30 条
[1]  
Lynn JG, Zwemer RL, Chick AJ, Miller AE, A new method for the generation and use of focused ultrasound in experimental biology, The Journal of General Physiology, 26, pp. 179-193, (1942)
[2]  
Fry WJ, Barnard JW, Fry FJ, Krumins RF, Brennan JF, Ultrasonic lesions in the mammalian central nervous system, Science, 122, pp. 517-518, (1955)
[3]  
Lele PP, A simple method for production of trackless focal lesions with focused ultrasound: physical factors, J Physiol, 160, pp. 494-512, (1962)
[4]  
Coleman DJ, Lizzi FL, Driller J, Et al., Therapeutic ultrasound in the treatment of glaucoma, Ophthalmology, 92, pp. 339-346, (1985)
[5]  
Moore WE, Lopez R, Matthews DE, Et al., Evaluation of high‐intensity therapeutic ultrasound Irradiation in the treatment of experimental hepatoma, J Pediatr Surg, 24, pp. 30-33, (1989)
[6]  
ter Haar G, Sinnett D, Rivens I, High intensity focused ultrasound: a surgical technique for the treatment of discrete liver tumors, Phys Med Biol, 34, pp. 1743-1750, (1989)
[7]  
Vallancien G, Harouni M, Veillon B, Et al., Focused extra‐corporeal pyrotherapy: feasibility study in man, Journal of Endourology, 6, pp. 173-180, (1992)
[8]  
Hynynen K, Roemer R, Anhalt D, Et al., A scanned, focussed, multiple transducer ultrasonic system for localized hyperthermia treatments, Int J Hyperthermia, 3, pp. 21-35, (1987)
[9]  
Hynynen K, Darkazanli A, Unger E, Schenck JF, MRI‐ guided noninvasive ultrasound surgery, Med Phys, 20, pp. 107-115, (1993)
[10]  
Darkazanli A, Hynynen K, Unger E, Schenck JF, On‐line monitoring of ultrasonic surgery with MR Imaging, JMRI, 3, pp. 509-514, (1993)