MAGNETOOPTIC MAGNETIC-FIELD SENSOR WITH 1.4PT/ROOT(HZ) MINIMUM DETECTABLE FIELD AT 1 KHZ

被引:16
|
作者
DEETER, MN [1 ]
DAY, GW [1 ]
BEAHN, TJ [1 ]
MANHEIMER, M [1 ]
机构
[1] US DEPT DEF,PHYS SCI LAB,COLL PK,MD 20740
关键词
MAGNETOOPTICAL DEVICES; MEASUREMENT;
D O I
10.1049/el:19930661
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Letter demonstrates that the sensitivity of magneto-optic magnetic field sensors employing iron garnets can be increased by approximately two orders of magnitude by applying flux concentration. A minimum detectable field of 1.4 pT/square-root (Hz) was measured when a cylindrical gallium-substituted yttrium iron garnet crystal was combined with two conically tapered nickel-zinc ferrite cylinders.
引用
收藏
页码:993 / 994
页数:2
相关论文
共 17 条
  • [1] MAGNETIC-FIELD DIRECTIONAL DISCONTINUITIES .1. MINIMUM VARIANCE ERRORS
    LEPPING, RP
    BEHANNON, KW
    JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 1980, 85 (NA9): : 4695 - 4703
  • [2] Increased DNA synthesis in INIT/10T1/2 cells after exposure to a 60 Hz magnetic field: A magnetic-field or a thermal effect?
    Zhao, YL
    Johnson, PG
    Jahreis, GP
    Hui, SW
    RADIATION RESEARCH, 1999, 151 (02) : 201 - 208
  • [3] ON THE PERMITTIVITY OF MAGNETIC COLLOIDS SUBJECT TO A STRONG EXTERNAL MAGNETIC-FIELD OVER THE FREQUENCY-RANGE 50 KHZ TO 1 MHZ
    FANNIN, PC
    SCAIFE, BK
    CHARLES, SW
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1993, 122 (1-3) : 168 - 171
  • [4] MAGNETIC-FIELD AND FIELD GRADIENT CORRECTIONS WITHIN A NONCONDUCTING SENSOR ENCLOSURE IN A CONDUCTING FLUID .1. POTENTIAL FLOW
    JOSEPH, RI
    THOMAS, ME
    ALLEN, KR
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1983, 21 (04): : 409 - 416
  • [5] Update of the Magnetic field (1Hz-100kHz) Exposure, Nov 2010 and its Implication on the Radiation Law in Israel
    Netzer, Moshe
    2011 IEEE INTERNATIONAL CONFERENCE ON MICROWAVES, COMMUNICATIONS, ANTENNAS AND ELECTRONIC SYSTEMS (COMCAS 2011), 2011,
  • [6] Detection of Magnetization of 6Hz, 10 μT Magnetic Field Applied Water Using PT-MI Sensor
    Mohri, K.
    Fukushima, M.
    Mohri, Y.
    Mohri, Yu.
    PIERS 2010 XI'AN: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2010, : 205 - +
  • [7] INTERPLANETARY MAGNETIC-FIELD POWER SPECTRA WITH FREQUENCIES FROM 2.4 X 10-5 HZ TO 470 HZ FROM HELIOS-OBSERVATIONS DURING SOLAR MINIMUM CONDITIONS
    DENSKAT, KU
    BEINROTH, HJ
    NEUBAUER, FM
    JOURNAL OF GEOPHYSICS-ZEITSCHRIFT FUR GEOPHYSIK, 1983, 54 (01): : 60 - 67
  • [8] A pT/√Hz sensitivity ac magnetic field sensor based on magnetoelectric composites using low-loss piezoelectric single crystals
    Annapureddy, Venkateswarlu
    Palneedi, Haribabu
    Yoon, Woon-Ha
    Park, Dong-Soo
    Choi, Jong-Jin
    Hahn, Byung-Dong
    Ahn, Cheol-Woo
    Kim, Jong-Woo
    Jeong, Dae-Yong
    Ryu, Jungho
    SENSORS AND ACTUATORS A-PHYSICAL, 2017, 260 : 206 - 211
  • [9] CANCER PROMOTION IN A MOUSE-SKIN MODEL BY A 60-HZ MAGNETIC-FIELD .1. EXPERIMENTAL-DESIGN AND EXPOSURE SYSTEM
    STUCHLY, MA
    LECUYER, DW
    MCLEAN, J
    BIOELECTROMAGNETICS, 1991, 12 (05) : 261 - 271
  • [10] 60 HZ MAGNETIC-FIELD ACTA AS CO-PROMOTER IN FOCUS FORMATION OF C3H/10T1/2 CELLS
    CAIN, CD
    THOMAS, DL
    ADEY, WR
    CARCINOGENESIS, 1993, 14 (05) : 955 - 960