PREOPERATIVE EVALUATION OF INTRAABDOMINAL TUMORS IN CHILDREN - GRADIENT-RECALLED ECHO VS SPIN-ECHO MR-IMAGING

被引:2
|
作者
SHADY, KL [1 ]
SIEGEL, MJ [1 ]
BROWN, JJ [1 ]
机构
[1] WASHINGTON UNIV,SCH MED,EDWARD MALLINCKRODT INST RADIOL,DEPT RADIOL,510 S KINGSHIGHWAY BLVD,ST LOUIS,MO 63110
关键词
D O I
10.2214/ajr.161.4.8372772
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare gradient-recalled echo (GRE) with spin-echo (SE) MR imaging in the assessment of vessel patency and tumor margins in children with intraabdominal tumors. MATERIALS AND METHODS. Findings on GRE and SE images in 10 children with abdominal neoplasms were retrospectively evaluated and compared with pathologic findings or results of CT studies. RESULTS. Detection of tumor thrombus was 100% with GRE sequences and 75% with SE sequences. The SE sequences yielded two false-positive diagnoses of tumor thrombosis, whereas the GRE sequences yielded no false-positive or false-negative diagnoses. In patients with extrinsic compression of the inferior vena cava by tumor, GRE images were consistently better than SE images for confirming vessel patency. GRE images also were superior to SE images at showing flow in mesenteric vessels, renal arteries, and renal veins. However, GRE images displayed tumor margins less well than SE images did, and they were also more susceptible to ghosting artifacts. CONCLUSION. Our results suggest that the GRE sequence is a useful adjunct to SE sequences for evaluating vascular involvement in children with abdominal tumors.
引用
收藏
页码:843 / 847
页数:5
相关论文
共 50 条
  • [1] EVALUATION OF MALIGNANT BILIARY OBSTRUCTION - EFFICACY OF FAST MULTIPLANAR SPOILED GRADIENT-RECALLED MR-IMAGING VS SPIN-ECHO MR-IMAGING, CT, AND CHOLANGIOGRAPHY
    LOW, RN
    SIGETI, JS
    FRANCIS, IR
    WEINMAN, D
    BOWER, B
    SHIMAKAWA, A
    FOO, TKF
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (02) : 315 - 323
  • [2] MR-IMAGING OF PERITONEAL DISEASE - COMPARISON OF CONTRAST-ENHANCED FAST MULTIPLANAR SPOILED GRADIENT-RECALLED AND SPIN-ECHO IMAGING
    LOW, RN
    SIGETI, JS
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (05) : 1131 - 1140
  • [3] MR IMAGING OF THE CAVERNOUS SINUS - VALUE OF SPIN-ECHO AND GRADIENT RECALLED ECHO IMAGES
    DANIELS, DL
    CZERVIONKE, LF
    BONNEVILLE, JF
    CATTIN, F
    MARK, LP
    PECH, P
    HENDRIX, LE
    SMITH, DF
    HAUGHTON, VM
    WILLIAMS, AL
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1988, 9 (05) : 947 - 952
  • [4] MR IMAGING OF THE CAVERNOUS SINUS - VALUE OF SPIN-ECHO AND GRADIENT RECALLED ECHO IMAGES
    DANIELS, DL
    CZERVIONKE, LF
    BONNEVILLE, JF
    CATTIN, F
    MARK, LP
    PECH, P
    HENDRIX, LE
    SMITH, DF
    HAUGHTON, VM
    WILLIAMS, AL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (05) : 1009 - 1014
  • [5] Comparison of gradient-recalled echo and spin-echo echo-planar imaging MR elastography in staging liver fibrosis: a meta-analysis
    Yong Seek Kim
    Yu Na Jang
    Ji Soo Song
    European Radiology, 2018, 28 : 1709 - 1718
  • [6] Comparison of gradient-recalled echo and spin-echo echo-planar imaging MR elastography in staging liver fibrosis: a meta-analysis
    Kim, Yong Seek
    Jang, Yu Na
    Song, Ji Soo
    EUROPEAN RADIOLOGY, 2018, 28 (04) : 1709 - 1718
  • [7] MR-IMAGING OF THE BRAIN - COMPARISON OF GRADIENT-ECHO AND SPIN-ECHO PULSE SEQUENCES
    PUI, MH
    FOK, ECM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (04) : 959 - 962
  • [8] FAST MULTIPLANAR SPOILED GRADIENT-RECALLED IMAGING OF THE LIVER - PULSE SEQUENCE OPTIMIZATION AND COMPARISON WITH SPIN-ECHO MR IMAGING
    LOW, RN
    FRANCIS, IR
    HERFKENS, RJ
    JEFFREY, RB
    GLAZER, GM
    FOO, TKF
    SHIMAKAWA, A
    PELC, NJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) : 501 - 509
  • [9] ACUTE HYPERTENSIVE ENCEPHALOPATHY - FINDINGS ON SPIN-ECHO AND GRADIENT-ECHO MR-IMAGING
    WEINGARTEN, K
    BARBUT, D
    FILIPPI, C
    ZIMMERMAN, RD
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (03) : 665 - 670
  • [10] EFFECT OF MAGNETIC-SUSCEPTIBILITY CONTRAST-MEDIUM ON MYOCARDIAL SIGNAL INTENSITY WITH FAST GRADIENT-RECALLED ECHO AND SPIN-ECHO MR-IMAGING - INITIAL EXPERIENCE IN HUMANS
    SAKUMA, H
    OSULLIVAN, M
    LUCAS, J
    WENDLAND, MF
    SAEED, M
    DULCE, MC
    WATSON, A
    BLEYL, KL
    LAFRANCE, ND
    HIGGINS, CB
    RADIOLOGY, 1994, 190 (01) : 161 - 166