3D LOCALIZED 2D NMR-SPECTROSCOPY ON AN MRI SCANNER

被引:74
作者
RYNER, LN
SORENSON, JA
THOMAS, MA
机构
[1] UNIV WISCONSIN,DEPT MED PHYS,MADISON,WI 53705
[2] UNIV WISCONSIN,DEPT RADIOL,MADISON,WI 53705
来源
JOURNAL OF MAGNETIC RESONANCE SERIES B | 1995年 / 107卷 / 02期
关键词
D O I
10.1006/jmrb.1995.1068
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Three-dimensionally localized versions of several two-dimensional NMR sequences have been implemented on a 1.5 T whole-body MRI/MRS scanner. In addition to the localization of voxels, the slice-selective RF pulses were also used for refocusing/transfer of various coherences in the 2D NMR sequences. Initial phantom and in vivo human studies are presented here. The sequences were localized versions of 2D J-resolved, 2D zero-quantum, 2D double-quantum, zero-quantum-filtered COSY and SECSY, and double-quantum-filtered COSY and SECSY. Two-dimensional plots for the J-resolved and multiple-quantum sequences are presented for a phantom containing an aqueous solution of 10 mM alanine. Sensitivity of different multiple-quantum-coherence orders to B-0 inhomogeneity is discussed. Localized double-quantum-filtered COSY of a phantom containing physiological concentrations of several metabolites also is presented to demonstrate the feasibility of performing this technique within time limits reasonable for human comfort. The first-reported 2D J-resolved H-1 in vivo MR spectrum localized in three dimensions in presented here, acquired predominantly from the cerebral white matter of a healthy volunteer and demonstrating the use of localized 2D NMR techniques in vivo. (C) 1995 Academic Press, Inc.
引用
收藏
页码:126 / 137
页数:12
相关论文
共 41 条
[21]  
Gillet B., Mergui S., Beloeil J.C., Champagnat J., Fortin G., Jacquin T., Magn. Reson. Med., 11, (1989)
[22]  
Hurd R.E., Freeman D.M., Proc. Natl. Acad. Sci. USA, 86, (1989)
[23]  
Desmoulin F., Seelig J., Magn. Reson. Med., 14, (1990)
[24]  
Van Zijl P.C.M., Chesnick A.S., Despres D., Moonen C.T.W., Ruiz-Cabello J., Van Gelderen P., Magn. Reson. Med., 30, (1993)
[25]  
Bellemann M.E., Bachert P., Lorenz W.J., Abstracts of the Society of Magnetic Resonance in Medicine, 2, (1992)
[26]  
Bottomley P.A., Dumoulin C.L., Abstracts of the Society of Magnetic Resonance in Medicine, 1, (1992)
[27]  
Michaelis T., Merboldt K.D., Bruhn H., Hanicke W., Frahm J., Radiology, 187, (1993)
[28]  
Pauly J., Le Roux P., Nishimura D., Macovski A., IEEE Ml, 53, (1991)
[29]  
Thomas M.A., Rodriguez R., Ryner L., Mehta M., Brown W.D., Rozental J., Turski P., Abstracts of the Society of Magnetic Resonance in Medicine, 2, (1992)
[30]  
Barker P., Freeman R., J. Magn. Reson., 64, (1985)