A MICROPROCESSOR-BASED QUADRILATERAL DISTANCE RELAY FOR EHV/UHV TRANSMISSION-LINE PROTECTION

被引:0
|
作者
VISHWAKARMA, DN [1 ]
RAM, B [1 ]
机构
[1] UNIV PATNA,BIHAR COLL ENGN,DEPT ELECT ENGN,PATNA 800005,BIHAR,INDIA
来源
JOURNAL OF MICROCOMPUTER APPLICATIONS | 1992年 / 15卷 / 04期
关键词
D O I
10.1016/0745-7138(92)90014-V
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents an Intel 8086 microprocessor-based quadrilateral distance relay suitable for the protection of EHV UHV transmission lines. The digital filtering algorithm used for extracting the fundamental frequency components from the complex post-fault relaying signals is based on rationalized Haar transform (RHT). The real and reactive components (R and X) of the apparent impedance of the line as seen by the relay are computed by using the real and imaginary components of the fundamental frequency voltage and current phasors. Using the computed values of R and X, the microprocessor examines whether the fault point lies within the quadrilateral relay's protective zone or not. If the fault point lies in the protective zone of the relay, the microprocessor issues a trip signal to the circuit breaker. The proposed distance relay is reliable, flexible, accurate and fast. © 1992.
引用
收藏
页码:347 / 360
页数:14
相关论文
共 50 条
  • [1] MICROPROCESSOR BASED 3 STEP QUADRILATERAL DISTANCE RELAY FOR THE PROTECTION OF EHV/UHV TRANSMISSION-LINES
    GANGADHARAN, G
    ANBALAGAN, P
    IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (01) : 91 - 97
  • [2] MICROPROCESSOR BASED PROTECTION SCHEME FOR EHV/UHV TRANSMISSION LINE.
    Sunnak, V.P.
    Singh, L.P.
    Journal of the Institution of Engineers (India): Electrical Engineering Division, 1984, 65 (pt 2-3): : 89 - 96
  • [3] ON LINE MICROPROCESSOR BASED RELAYING SCHEME FOR EHV/UHV TRANSMISSION-LINE - AN EXISTING 400 KV LINE
    ISLAM, KK
    BOSE, SK
    SINGH, LP
    ELECTRIC MACHINES AND POWER SYSTEMS, 1987, 12 (4-5): : 313 - 324
  • [4] DIGITAL PROTECTION OF EHV UHV TRANSMISSION-LINE BASED UPON TRAVELING WAVE PHENOMENA
    ISLAM, KK
    BOSE, SK
    SINGH, LP
    ELECTRIC MACHINES AND POWER SYSTEMS, 1988, 14 (06): : 413 - 431
  • [5] A microprocessor-based high-speed relay for protection of parallel EHV/UHV feeders using waveform comparison technique
    Sengupta, S
    Mukhopadhyay, AK
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2003, 31 (09) : 891 - 897
  • [6] TRANSIENT SIGNALS AND THEIR PROCESSING IN AN ULTRA HIGH-SPEED DIRECTIONAL RELAY FOR EHV UHV TRANSMISSION-LINE PROTECTION
    ENGLER, F
    LANZ, OE
    HANGGLI, M
    BACCHINI, G
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (06): : 1463 - 1473
  • [7] Microprocessor-based distance relay
    Hussain, FMA
    Khan, N
    Mariun, N
    Mahmod, S
    NATIONAL POWER ENGINEERING CONFERENCE PECON 2003, PROCEEDINGS, 2003, : 43 - 46
  • [9] A Novel UHV/EHV Transmission-Line Pilot Protection Based on Fault Component Integrated Impedance
    Suonan, Jiale
    Liu, Kai
    Song, Guobing
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (01) : 127 - 134
  • [10] Support Vector Machine based High speed Protection Relay for EHV/UHV Transmission Line
    Ravishankar, K.
    Thukaram, D.
    2012 2ND INTERNATIONAL CONFERENCE ON POWER, CONTROL AND EMBEDDED SYSTEMS (ICPCES 2012), 2012,