ACUTE STROKE IN CATS - COMPARISON OF DYNAMIC SUSCEPTIBILITY-CONTRAST MR-IMAGING WITH T2-WEIGHTED AND DIFFUSION-WEIGHTED MR-IMAGING

被引:39
作者
MAEDA, M [1 ]
ITOH, S [1 ]
IDE, H [1 ]
MATSUDA, T [1 ]
KOBAYASHI, H [1 ]
KUBOTA, T [1 ]
ISHII, Y [1 ]
机构
[1] FUKUI MED SCH,DEPT NEUROSURG,FUKUI 91011,JAPAN
关键词
BRAIN; ISCHEMIA; CEREBRAL BLOOD VESSELS; FLOW DYNAMICS; STENOSIS OR OBSTRUCTION; MAGNETIC RESONANCE (MR); CONTRAST ENHANCEMENT; DIFFUSION STUDY;
D O I
10.1148/radiology.189.1.8372198
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the hemodynamics of acute stroke in cats by means of dynamic susceptibility-contrast magnetic resonance (MR) imaging compared with standard T2- and diffusion-weighted MR imaging. MATERIALS AND METHODS: Unilateral permanent occlusion of the middle cerebral artery was performed in 18 cats. MR imaging was performed with each method 2 hours (n = 2), 6 hours (n = 10), and 24 hours (n = 11) after occlusion. RESULTS: At every time point, dynamic MR images clearly showed ischemic regions of steady-state signal hyperintensity and areas of less dynamic decrease in signal intensity that corresponded closely to those seen on diffusion-weighted MR images. T2-weighted MR images did not reveal regions of high signal intensity 2 hours after occlusion. The measurements of relative blood volume obtained with the dynamic method were significantly lower in steady-state hyperintense ischemic areas of the affected side than those in the contralateral normal areas at 6 and 24 hours (P < .001). CONCLUSION: This dynamic method can advance the time of detection of early ischemia in comparison with T2-weighted MR imaging and provides functional information about hemodynamics not provided by other methods of MR imaging.
引用
收藏
页码:227 / 232
页数:6
相关论文
共 25 条
[1]   FUNCTIONAL CEREBRAL IMAGING BY SUSCEPTIBILITY-CONTRAST NMR [J].
BELLIVEAU, JW ;
ROSEN, BR ;
KANTOR, HL ;
RZEDZIAN, RR ;
KENNEDY, DN ;
MCKINSTRY, RC ;
VEVEA, JM ;
COHEN, MS ;
PYKETT, IL ;
BRADY, TJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (03) :538-546
[2]   MECHANISM OF DETECTION OF ACUTE CEREBRAL-ISCHEMIA IN RATS BY DIFFUSION-WEIGHTED MAGNETIC-RESONANCE MICROSCOPY [J].
BENVENISTE, H ;
HEDLUND, LW ;
JOHNSON, GA .
STROKE, 1992, 23 (05) :746-754
[3]   EVOLVING FOCAL CEREBRAL-ISCHEMIA IN CATS - SPATIAL CORRELATION OF NUCLEAR MAGNETIC-RESONANCE IMAGING, CEREBRAL BLOOD-FLOW, TETRAZOLIUM STAINING, AND HISTOPATHOLOGY [J].
BOSE, B ;
JONES, SC ;
LORIG, R ;
FRIEL, HT ;
WEINSTEIN, M ;
LITTLE, JR .
STROKE, 1988, 19 (01) :28-37
[4]  
BROWN JJ, 1988, AM J NEURORADIOL, V9, P477
[5]   CEREBRAL BLOOD-FLOW - ASSESSMENT WITH DYNAMIC CONTRAST-ENHANCED T2-STAR-WEIGHTED MR IMAGING AT 1.5-T [J].
EDELMAN, RR ;
MATTLE, HP ;
ATKINSON, DJ ;
HILL, T ;
FINN, JP ;
MAYMAN, C ;
RONTHAL, M ;
HOOGEWOUD, HM ;
KLEEFIELD, J .
RADIOLOGY, 1990, 176 (01) :211-220
[6]  
HAMBERG LM, 1992, 1992 SOC MAGN RES ME, P917
[7]  
JIANG Q, 1992, 1992 SOC MAGN RES ME, P1807
[8]   THE SENSITIVITY AND SPECIFICITY OF MRI IN STROKE [J].
KERTESZ, A ;
BLACK, SE ;
NICHOLSON, L ;
CARR, T .
NEUROLOGY, 1987, 37 (10) :1580-1585
[9]   ISCHEMIC BRAIN-DAMAGE - REDUCTION BY SODIUM-CALCIUM ION CHANNEL MODULATOR RS-87476 [J].
KUCHARCZYK, J ;
MINTOROVITCH, J ;
MOSELEY, ME ;
ASGARI, HS ;
SEVICK, RJ ;
DERUGIN, N ;
NORMAN, D .
RADIOLOGY, 1991, 179 (01) :221-227
[10]   DIFFUSION PERFUSION MR IMAGING OF ACUTE CEREBRAL-ISCHEMIA [J].
KUCHARCZYK, J ;
MINTOROVITCH, J ;
ASGARI, HS ;
MOSELEY, M .
MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) :311-315