DIFFERENCES IN ELBOW FLEXION TORQUE MEASURED CONCENTRICALLY, ECCENTRICALLY, AND ISOMETRICALLY

被引:50
作者
GRIFFIN, JW
机构
来源
PHYSICAL THERAPY | 1987年 / 67卷 / 08期
关键词
D O I
10.1093/ptj/67.8.1205
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purposes of this study were to describe torque-velocity relationships during concentric, eccentric, and isometric testing of elbow flexor muscles and to determine test-retest reliability of a specific isokinetic testing protocol. Thirty healthy women were tested using an isokinetic dynamometer at velocities of 0°, 30°, 120°, and 210°/sec. Reliability was assessed in 20 of the subjects by retesting concentric and eccentric torques at 30° and 120°/sec after a 30-minute rest interval. The highest torque from three maximal efforts was considered to be peak torque. Mean eccentric peak torque was greater than either isometric or concentric peak torque; as isokinetic test velocity increased, the differences between concentric and eccentric torques became larger. Intraclass correlation coefficients ranged from .72 to .83, indicating lack of consistency between test and retest torques. Consecutive concentric-eccentric testing and lack of mechanical stabilization might have contributed to test-retest variability and to the relatively small differences between concentric and eccentric torques. Continued study of reliability of isokinetic testing protocols and further investigation of concentric-eccentric torque-velocity relationships are advocated.
引用
收藏
页码:1205 / 1208
页数:4
相关论文
共 22 条
[1]   STORAGE OF ELASTIC ENERGY IN SKELETAL-MUSCLES IN MAN [J].
ASMUSSEN, E ;
BONDEPET.F .
ACTA PHYSIOLOGICA SCANDINAVICA, 1974, 91 (03) :385-392
[2]  
ASMUSSEN E, 1965, COMMUN DAN NAT ASS, V20, P3
[3]   THE RELATIONSHIP OF MOTOR-UNIT ACTIVATION TO ISOKINETIC MUSCULAR-CONTRACTION AT DIFFERENT CONTRACTILE VELOCITIES [J].
BARNES, WS .
PHYSICAL THERAPY, 1980, 60 (09) :1152-1158
[4]  
CAVAGNA GA, 1979, EXERCISE SPORT SCI R, V5, P89
[5]   A COMPARISON OF CONCENTRIC ECCENTRIC AND ISOMETRIC STRENGTH OF ELBOW FLEXORS [J].
DOSS, WS ;
KARPOVICH, PV .
JOURNAL OF APPLIED PHYSIOLOGY, 1965, 20 (02) :351-+
[6]  
FARRELL M, 1986, MED SCI SPORT EXER, V18, P44
[7]  
GOLSIN BR, 1979, SCAND J REHABIL MED, V11, P105
[8]  
KERLINGER FN, 1964, F BEHAVIORAL RES ED, pCH24
[9]   ISOMETRIC, ISOTONIC, AND ISOKINETIC TORQUE VARIATIONS IN 4 MUSCLE GROUPS THROUGH A RANGE OF JOINT MOTION [J].
KNAPIK, JJ ;
WRIGHT, JE ;
MAWDSLEY, RH ;
BRAUN, J .
PHYSICAL THERAPY, 1983, 63 (06) :938-947
[10]  
KNAPIK JJ, 1980, ARCH PHYS MED REHAB, V61, P64