LOW-GRAVITY SENSING OF LIQUID-VAPOR INTERFACE AND TRANSIENT LIQUID FLOW

被引:7
作者
JACOBSON, SA [1 ]
KORBA, JM [1 ]
LYNNWORTH, LC [1 ]
NGUYEN, TH [1 ]
ORTON, GF [1 ]
ORAZIETTI, AJ [1 ]
机构
[1] MCDONNELL DOUGLAS CORP,ST LOUIS,MO 63166
关键词
D O I
10.1109/T-UFFC.1987.26934
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
引用
收藏
页码:212 / 224
页数:13
相关论文
共 26 条
[1]  
ARAVE A, 1978, 24TH P INT INSTR S I, P609
[2]  
BAU HH, 1986, T ASME, V53, P846
[3]   THE VELOCITY OF SOUND IN METALS AT HIGH TEMPERATURES [J].
BELL, JFW .
PHILOSOPHICAL MAGAZINE, 1957, 2 (21) :1113-1120
[4]   DESIGN AND CONSTRUCTION OF A PULSED ULTRASONIC AIR FLOWMETER [J].
BUESS, C ;
PIETSCH, P ;
GUGGENBUHL, W ;
KOLLER, EA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (08) :768-774
[5]  
DRESS WB, 1983 P ULTR S, P287
[6]  
Knapp C., 1964, VDI BERICHTE DURCHFL, V86, P65
[7]  
LYNNWORT.LC, 1973, J TEST EVAL, V1, P119, DOI 10.1520/JTE10886J
[8]  
Lynnworth L. C., 1982, Transactions of the Institute of Measurement and Control, V4, P2, DOI 10.1177/014233128200400101
[9]  
Lynnworth L. C., 1977, 1977 Ultrasonics Symposium Proceedings, P29, DOI 10.1109/ULTSYM.1977.196787
[10]   FAST RESPONSE ULTRASONIC FLOWMETER MEASURES BREATHING DYNAMICS [J].
LYNNWORTH, LC ;
KORBA, JM ;
WALLACE, DR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (07) :530-535