Reducing Risk During Endoscopy in Patients with Implanted Electronic Devices

被引:2
作者
Petersen, Bret T. [1 ]
机构
[1] Mayo Clin, Rochester, MN USA
关键词
electrosurgery; electrocautery; implanted electronic devices; pacemaker; intracardiac defibrillator; ICD;
D O I
10.1016/j.tgie.2007.09.001
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
The implantation of electronic devices to monitor and alter cardiac or neurologic function or to deliver pharmaceuticals is becoming commonplace. Gastrointestinal endoscopists should be attentive to the presence of implanted electronic devices and aware of the basic means for limiting risk during the use of electrocautery in patients who have such devices in place. The risk is relatively limited in most patients, and precautions for reducing risk are easily employed. Generic and specific recommendations are discussed pertinent to use of electrocautery in patients with cardiac and neurologic devices. Selected pacemaker-dependent patients with implanted intracardiac defibrillators and those with implanted deep brain stimulators or gastric pacing devices warrant specific specialty comment before endoscopy. Additional data are needed regarding the general safety of endoscopic electrocautery and the recommended precautions in these patients. (C) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:208 / 212
页数:5
相关论文
共 21 条
[1]  
[Anonymous], 2002, GASTR ELECT STIM SYS
[2]  
[Anonymous], 2004, QUEST ANSW ACT PARK
[3]   EFFECT OF COAGULATING AND CUTTING CURRENT ON A DEMAND PACEMAKER DURING TRANSURETHRAL RESECTION OF PROSTATE - CASE-REPORT [J].
BATRA, YK ;
BALI, IM .
CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1978, 25 (01) :65-66
[4]   Application of radiofrequency energy in surgical and interventional procedures: Are there interactions with ICDs? [J].
Fiek, M ;
Dorwarth, U ;
Durchlaub, I ;
Janko, S ;
Von Bary, C ;
Steinbeck, G ;
Hoffmann, E .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (03) :293-298
[5]   Environmental and drug effects on patients with pacemakers and implantable cardioverter/defibrillators -: A practical guide to patient treatment [J].
Goldschlager, N ;
Epstein, A ;
Friedman, P ;
Gang, E ;
Krol, R ;
Olshansky, B .
ARCHIVES OF INTERNAL MEDICINE, 2001, 161 (05) :649-655
[6]   Deaths associated with implantable cardioverter defibrillator failure and deactivation reported in The United States Food and Drug Administration Manufacturer and User Facility Device Experience Database [J].
Hauser, RG ;
Kallinen, L .
HEART RHYTHM, 2004, 1 (04) :399-405
[7]  
Hayes DL, 2000, CLIN CARDIAC PACING
[8]   ENDOSCOPIC THERAPY USING MONOPOLAR AND BIPOLAR SNARE WITH A HIGH-FREQUENCY CURRENT IN PATIENTS WITH A PACEMAKER [J].
ITO, S ;
SHIBATA, H ;
OKAHISA, T ;
OKAMURA, S ;
WADA, S ;
YANO, M ;
SAIJYO, T ;
HONDA, H ;
HAYASHI, H ;
SHIMIZU, I ;
II, K .
ENDOSCOPY, 1994, 26 (02) :270-270
[9]   ELECTROCAUTERY AND PACEMAKERS - MANAGEMENT OF THE PACED PATIENT SUBJECT TO ELECTROCAUTERY [J].
LEVINE, PA ;
BALADY, GJ ;
LAZAR, HL ;
BELOTT, PH ;
ROBERTS, AJ .
ANNALS OF THORACIC SURGERY, 1986, 41 (03) :313-317
[10]   Surgical management of the patient with an implanted cardiac device - Implications of electromagnetic interference [J].
Madigan, JD ;
Choudhri, AF ;
Chen, J ;
Spotnitz, HM ;
Oz, MC ;
Edwards, N .
ANNALS OF SURGERY, 1999, 230 (05) :639-647