CALIBRATION OF THE NEUTRON-ACTIVATION SYSTEM ON THE FRASCATI TOKAMAK UPGRADE - COMPARISON BETWEEN MEASURED AND CALCULATED ACTIVATION RESPONSE COEFFICIENTS

被引:6
作者
ANGELONE, M
BATISTONI, P
MARTONE, M
PILLON, M
RAPISARDA, M
ROLLET, S
机构
来源
FUSION TECHNOLOGY | 1991年 / 19卷 / 03期
关键词
TOKAMAK; NEUTRON YIELD; ACTIVATION MEASUREMENTS;
D O I
10.13182/FST91-A29383
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The Frascati Tokamak Upgrade (FTU) neutron activation system has been calibrated using indium foils and a 252Cf spontaneous fission neutron source located at several positions within the tokamak. The same experimental arrangements have been simulated with the MCNP Monte Carlo neutron and photon transport code in order to numerically reproduce the activation response coefficients measured experimentally. The main purpose of the comparison is to assess the accuracy of the numerical simulation and of the modeling of the FTU device. This analysis has a more general relevance in view of the use of the activation system as an independent method for the absolute measurement of the neutron yield in next-step fusion devices. An overall agreement at the 22% level between experiment and calculation has been demonstrated.
引用
收藏
页码:431 / 439
页数:9
相关论文
共 15 条
[1]  
ANDREANI R, 1986, 14TH P S FUS TECHN A, V1, P149
[2]  
[Anonymous], 1986, LA7396M LOS AL NAT L
[3]  
BAARD JW, 1989, NUCLEAR DATA GUIDE R
[4]  
BARNES CW, 1988, 15TH P C CONTROL B U, V12, P87
[5]   MEASUREMENTS OF TRITON BURNUP IN LOW Q DISCHARGES IN THE FT TOKAMAK [J].
BATISTONI, P ;
MARTONE, M ;
PILLON, M ;
PODDA, S ;
RAPISARDA, M .
NUCLEAR FUSION, 1987, 27 (06) :1040-1043
[6]  
BATZNER R, 1989, 16TH P C CONTROL B 4, V13, P1449
[7]  
GRUNDL JA, 1986, NBSIR853151
[8]  
GRUPPELAAR H, 1988, EFFDOC17 ECN PETT
[9]   TRITON BURNUP MEASUREMENTS IN JET USING A NEUTRON-ACTIVATION TECHNIQUE [J].
KALLNE, J ;
BATISTONI, P ;
GORINI, G ;
HUXTABLE, GB ;
PILLON, M ;
PODDA, S ;
RAPISARDA, M .
NUCLEAR FUSION, 1988, 28 (07) :1291-1297
[10]   CALIBRATION OF THE TFTR NEUTRON-ACTIVATION SYSTEM [J].
NIESCHMIDT, EB ;
SAITO, T ;
BARNES, CW ;
BOSCH, HS ;
MURPHY, TJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (08) :1715-1717