摘要
Objective: To determine the utility of duplex ultrasound scanning of the renal arteries in identifying patients with renal artery stenosis of 60% or more and in excluding patients with either normal renal arteries or renal artery stenosis of less than 60%. Design: A prospective, blinded study. Setting: Large tertiary referral center. Patients: 102 consecutive patients (44 men and 58 women with a mean age [+/-SD] of 63.3 +/- 13.4 years) who had both duplex ultrasound scanning of the renal arteries and renal arteriography. All patients who were studied had hypertension that was difficult to control, unexplained azotemia, or associated peripheral vascular disease (alone or in combination), giving them a high pretest likelihood of renovascular disease. Main Outcome Measurements: Peak systolic and end diastolic velocities, renal-aortic ratios, resistive index, and kidney sizes. Results: Sixty-two of 63 arteries with stenosis of less than 60% using arteriography were correctly identified by duplex ultrasound scanning. Thirty-one of 32 arteries with 60% to 79% stenosis using arteriography were correctly identified as having 60% to 99% stenosis on duplex ultrasound, whereas 67 of 69 arteries with 80% to 99% stenosis on arteriography were correctly identified as having 60% to 99% stenosis on ultrasound. Twenty-two of 23 arteries with total occlusion on arteriography were correctly identified by duplex ultrasound. The overall sensitivity of duplex ultrasound compared with arteriography was 0.98, the specificity was 0.98, the positive predictive value was 0.99, and the negative predictive value was 0.97. Conclusion: Duplex ultrasound scanning of the renal arteries is an ideal screening test because it is noninvasive and can predict the presence or absence of renal artery stenosis with a high degree of accuracy.
引用
收藏
页码:833 / 838
页数:6
相关论文
共 50 条
  • [21] DEGREE OF RENAL-ARTERY STENOSIS ALTERS NITRIC-OXIDE REGULATION OF RENAL HEMODYNAMICS
    SIGMON, DH
    BEIERWALTES, WH
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1994, 5 (06): : 1369 - 1377
  • [22] THE CONCOMITANCE OF RENAL-ARTERY STENOSIS AND CONNS ADENOMA IN A HYPERTENSIVE WOMAN
    GHILARDI, G
    PIZZOCARI, P
    BORTOLANI, E
    DEMONTI, M
    LONGHI, F
    PANMINERVA MEDICA, 1991, 33 (01) : 53 - 56
  • [23] DUPLEX SONOGRAPHY OF RENAL-ARTERIES AS A DIAGNOSTIC-TOOL IN HYPERTENSIVE CHILDREN
    ROSENDAHL, W
    GRUNERT, D
    SCHONING, M
    EUROPEAN JOURNAL OF PEDIATRICS, 1994, 153 (08) : 588 - 593
  • [24] RENAL-ARTERY STENOSIS IN PATIENTS WITH AORTIC DISSECTION - INCREASED PREVALENCE
    RACKSON, ME
    LOSSEF, SV
    SOS, TA
    RADIOLOGY, 1990, 177 (02) : 555 - 558
  • [26] Renal Artery Duplex Ultrasound Criteria for the Detection of Significant In-Stent Restenosis
    del Conde, Ian
    Galin, Ira D.
    Trost, Biana
    Kang, Jeanwan
    Lookstein, Robert
    Woodward, Mark
    Gustavson, Susan
    Cambria, Richard P.
    Jaff, Michael R.
    Olin, Jeffrey W.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (04) : 612 - 618
  • [27] Atherosclerotic renal artery stenosis: is it worth diagnosing?
    Eardley, KS
    Lipkin, GW
    JOURNAL OF HUMAN HYPERTENSION, 1999, 13 (04) : 217 - 220
  • [28] RENAL-ARTERY STENOSIS AFTER RENAL-TRANSPLANTATION - THE IMPACT OF THE HYPOGASTRIC ARTERY ANASTOMOSIS
    SUTHERLAND, RS
    SPEES, EK
    JONES, JW
    FINK, DW
    JOURNAL OF UROLOGY, 1993, 149 (05) : 980 - 985
  • [29] Atherosclerotic renal artery stenosis: is it worth diagnosing?
    KS Eardley
    GW Lipkin
    Journal of Human Hypertension, 1999, 13 : 217 - 220
  • [30] RENAL ATROPHY AND ARTERIAL-STENOSIS - A PROSPECTIVE-STUDY WITH DUPLEX ULTRASOUND
    GUZMAN, RP
    ZIERLER, RE
    ISAACSON, JA
    BERGELIN, RO
    STRANDNESS, DE
    HYPERTENSION, 1994, 23 (03) : 346 - 350