RECENT ADVANCES IN PHARMACEUTICAL ANALYSIS WITH POTENTIOMETRIC MEMBRANE SENSORS

被引:153
作者
COSOFRET, VV
BUCK, RP
机构
[1] Department of Chemistry, University of North Carolina, Chapel Hill, NC
[2] Department of Chemistry, University of Michigan, Ann Arbor, MI
关键词
ION-SELECTIVE ELECTRODES; MEMBRANE SENSORS; DRUGS; PHARMACEUTICAL ANALYSIS; DISSOLUTION; PHARMACOKINETICS;
D O I
10.1080/10408349308048818
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development and applications of ion-selective membrane electrodes continue to provide excitement is expanding areas of analytical chemistry, including analytical pharmaceutical research and analysis, because these sensors offer the advantages of simple design, construction, and manipulation, reasonable selectivity, fast response time, applicability to colored and turbid solutions, and possible interfacing with automated and computerized systems. The combination of membrane sensors with flow injection analysis (FIA) for the determination of various organic ions of biological interest (e.g., drugs) is a new promising area with many applications. This review covers the material that is of interest to those who deal with ion-selective electrodes in organic and pharmaceutical analysis.
引用
收藏
页码:1 / 58
页数:58
相关论文
共 133 条
[1]  
AHUJA S, 1991, CHIRAL SEPARATIONS L
[2]  
AMMANN D, 1983, ION SEL ELECTRODE R, V5, P3
[3]   USE OF ION-SELECTIVE ELECTRODES IN KINETIC FLOW-INJECTION - DETERMINATION OF PHENOLIC AND HYDRAZINO DRUGS WITH 1-FLUORO-2,4-DINITROBENZENE USING A FLUORIDE-SELECTIVE ELECTRODE [J].
APOSTOLAKIS, JC ;
GEORGIOU, CA ;
KOUPPARIS, MA .
ANALYST, 1991, 116 (03) :233-237
[4]   SEMI-AUTOMATED KINETIC DETERMINATION OF PHENOLIC-COMPOUNDS USING A FLUORIDE-SELECTIVE ELECTRODE AND BASED ON THEIR MICELLAR-CATALYZED REACTION WITH 1-FLUORO-2,4-DINITROBENZENE [J].
ARCHONTAKI, HA ;
KOUPPARIS, MA ;
EFSTATHIOU, CE .
ANALYST, 1989, 114 (05) :591-596
[5]   KINETIC-POTENTIOMETRIC STUDY AND ANALYTICAL APPLICATIONS OF MICELLAR-CATALYZED REACTIONS OF 1-FLUORO-2,4-DINITROBENZENE WITH AMINO-COMPOUNDS [J].
ATHANASIOUMALAKI, E ;
KOUPPARIS, MA .
ANALYTICA CHIMICA ACTA, 1989, 219 (02) :295-307
[6]   KINETIC - POTENTIOMETRIC DETERMINATION OF AMINO-ACIDS BASED ON MONITORING THEIR REACTION WITH DINITROFLUOROBENZENE USING A FLUORIDE-SELECTIVE ELECTRODE [J].
ATHANASIOUMALAKI, E ;
KOUPPARIS, MA .
ANALYST, 1987, 112 (06) :757-761
[7]   KINETIC-STUDY OF THE DETERMINATION OF HYDRAZINES, ISONIAZID AND SODIUM-AZIDE BY MONITORING THEIR REACTIONS WITH 1-FLUORO-2,4-DINITROBENZENE, BY MEANS OF A FLUORIDE-SELECTIVE ELECTRODE [J].
ATHANASIOUMALAKI, E ;
KOUPPARIS, MA .
TALANTA, 1989, 36 (04) :431-436
[8]   KINETIC DETERMINATION OF PRIMARY AND SECONDARY-AMINES USING A FLUORIDE-SELECTIVE ELECTRODE AND BASED ON THEIR REACTION WITH 1-FLUORO-2,4-DINITROBENZENE [J].
ATHANASIOUMALAKI, E ;
KOUPPARIS, MA ;
HADJIIOANNOU, TP .
ANALYTICAL CHEMISTRY, 1989, 61 (13) :1358-1363
[9]   FABRICATION OF A BERBERINE-SENSOR AND ITS PROPERTIES [J].
AUBECK, R ;
HAMPP, N ;
BRAUCHLE, C .
BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1988, 92 (11) :1423-1426
[10]   ION-SELECTIVE MEMBRANE ELECTRODES FOR THE DETERMINATION OF THE MUSCLE-RELAXANTS PANCURONIUM, TUBOCURARINE, GALLAMINE AND SUCCINYLCHOLINE [J].
AUBECK, R ;
BRAUCHLE, C ;
HAMPP, N .
ANALYTICA CHIMICA ACTA, 1990, 238 (02) :405-410