Comparison between automated and manual measurements of carotid intima-media thickness in clinical practice

被引:0
作者
Vilas Freire, Claudia Maria [1 ]
Pinho Ribeiro, Antonio Luiz [1 ]
Lima Barbosa, Felipe Batista [1 ]
Nogueira, Anelise Impelisiere [1 ]
Costa de Almeida, Maria Cristina [1 ,4 ]
Barbosa, Marcia Melo [4 ]
Quintao Lana, Angela Maria [2 ]
Simoes e Silva, Ana Cristina [3 ]
Ribeiro-Oliveira, Antonio, Jr. [1 ]
机构
[1] Univ Fed Minas Gerais, Sch Med, Dept Internal Med, Belo Horizonte, MG, Brazil
[2] Univ Fed Minas Gerais, Vet Dept, Stat Lab, Belo Horizonte, MG, Brazil
[3] Univ Fed Minas Gerais, Sch Med, Dept Pediat, Belo Horizonte, MG, Brazil
[4] Hosp Socor, Ecoctr, Belo Horizonte, MG, Brazil
关键词
intima-media thickness; atherosclerosis; carotid segments; automated method; manual measurement; bland-altman plot;
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background and aim: The measurement of carotid intima-media thickness (cIMT) has been used as a marker of arterial wall disease. Manual measurements have been performed in most epidemiological studies, but, due to the introduction of new technologies, automated software has been increasingly used. This study aimed to compare manual versus automated cIMT measurements in common carotid (CC), bifurcation (BIF), and internal carotid (IC). Methods: Automated and manual cIMT measurements were performed online in 43 middle-aged females. Carotid segment measurements were compared by Bland-Altman plot and the variation and repeatability coefficients between observers were also determined for comparison. Results: The average timespan for manual measurements (57.30 s) were significantly higher than for automated measurements (2.52 s). There were no systematic errors between methods in any carotid segments. The variation coefficient was 5.54% to 6.34% for CC and BIF, 9.76% for IC, and absolute differences were 85% below 0.1 mm and 70% below 0.05 mm. Interobserver agreement showed no systematic error. The variation and the repeatability coefficients were better for the automated than manual measures. Conclusion: Although both methods are reliable for cIMT measurements, the automated technique allows faster evaluation with lesser variability for all carotid segments currently used in atherosclerosis research.
引用
收藏
页码:811 / 817
页数:7
相关论文
共 28 条
[21]  
SALONEN JT, 1993, CIRCULATION, V87, P56
[22]   EVALUATION OF COMPUTERIZED EDGE TRACKING FOR QUANTIFYING INTIMA-MEDIA THICKNESS OF THE COMMON CAROTID-ARTERY FROM B-MODE ULTRASOUND IMAGES [J].
SELZER, RH ;
HODIS, HN ;
KWONGFU, H ;
MACK, WJ ;
LEE, PL ;
LIU, CR ;
LIU, CH .
ATHEROSCLEROSIS, 1994, 111 (01) :1-11
[23]   Intima-media thickness: a new tool for diagnosis and treatment of cardiovascular risk [J].
Simon, A ;
Gariepy, J ;
Chironi, G ;
Megnien, JL ;
Levenson, J .
JOURNAL OF HYPERTENSION, 2002, 20 (02) :159-169
[24]   Use of carotid ultrasound to identify subclinical vascular disease and evaluate cardiovascular disease risk: A consensus statement from the American society of echocardiography carotid intima-media thickness task force endorsed by the society for vascular medicine [J].
Stein, James H. ;
Korcarz, Claudia E. ;
Hurst, R. Todd ;
Lonn, Eva ;
Kendall, Christopher B. ;
Mohler, Emile R. ;
Najjar, Samcr S. ;
Rembold, Christopher M. ;
Post, Wendy S. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (02) :93-111
[25]   Design, baseline characteristics and carotid intima-media thickness reproducibility in the PARC study [J].
Touboul, PJ ;
Vicaut, E ;
Labreuche, J ;
Belliard, JP ;
Cohen, S ;
Kownator, S ;
Pithois-merli, I .
CEREBROVASCULAR DISEASES, 2005, 19 (01) :57-63
[26]   USE OF MONITORING SOFTWARE TO IMPROVE THE MEASUREMENT OF CAROTID WALL THICKNESS BY B-MODE IMAGING [J].
TOUBOUL, PJ ;
PRATI, P ;
SCARABIN, PY ;
ADRAI, V ;
THIBOUT, E ;
DUCIMETIERE, P .
JOURNAL OF HYPERTENSION, 1992, 10 :S37-S41
[27]   Mannheim intima-media thickness consensus [J].
Touboul, PJ ;
Hennerici, G ;
Meairs, S ;
Adams, H ;
Amarenco, P ;
Desvarieux, M ;
Ebrahim, S ;
Fatar, M ;
Hernandez, RH ;
Kownator, S ;
Prati, P ;
Rundek, T ;
Taylor, A ;
Bornstein, N ;
Csiba, L ;
Vicaut, E ;
Woo, KS ;
Zannad, F .
CEREBROVASCULAR DISEASES, 2004, 18 (04) :346-349
[28]   ATHEROSCLEROTIC CHANGES IN THE FEMORAL AND CAROTID ARTERIES IN FAMILIAL HYPERCHOLESTEROLEMIA - ULTRASONOGRAPHIC ASSESSMENT OF INTIMA-MEDIA THICKNESS AND PLAQUE OCCURRENCE [J].
WENDELHAG, I ;
WIKLUND, O ;
WIKSTRAND, J .
ARTERIOSCLEROSIS AND THROMBOSIS, 1993, 13 (10) :1404-1411