Comparison between automated and manual measurements of carotid intima-media thickness in clinical practice

被引:0
作者
Vilas Freire, Claudia Maria [1 ]
Pinho Ribeiro, Antonio Luiz [1 ]
Lima Barbosa, Felipe Batista [1 ]
Nogueira, Anelise Impelisiere [1 ]
Costa de Almeida, Maria Cristina [1 ,4 ]
Barbosa, Marcia Melo [4 ]
Quintao Lana, Angela Maria [2 ]
Simoes e Silva, Ana Cristina [3 ]
Ribeiro-Oliveira, Antonio, Jr. [1 ]
机构
[1] Univ Fed Minas Gerais, Sch Med, Dept Internal Med, Belo Horizonte, MG, Brazil
[2] Univ Fed Minas Gerais, Vet Dept, Stat Lab, Belo Horizonte, MG, Brazil
[3] Univ Fed Minas Gerais, Sch Med, Dept Pediat, Belo Horizonte, MG, Brazil
[4] Hosp Socor, Ecoctr, Belo Horizonte, MG, Brazil
关键词
intima-media thickness; atherosclerosis; carotid segments; automated method; manual measurement; bland-altman plot;
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background and aim: The measurement of carotid intima-media thickness (cIMT) has been used as a marker of arterial wall disease. Manual measurements have been performed in most epidemiological studies, but, due to the introduction of new technologies, automated software has been increasingly used. This study aimed to compare manual versus automated cIMT measurements in common carotid (CC), bifurcation (BIF), and internal carotid (IC). Methods: Automated and manual cIMT measurements were performed online in 43 middle-aged females. Carotid segment measurements were compared by Bland-Altman plot and the variation and repeatability coefficients between observers were also determined for comparison. Results: The average timespan for manual measurements (57.30 s) were significantly higher than for automated measurements (2.52 s). There were no systematic errors between methods in any carotid segments. The variation coefficient was 5.54% to 6.34% for CC and BIF, 9.76% for IC, and absolute differences were 85% below 0.1 mm and 70% below 0.05 mm. Interobserver agreement showed no systematic error. The variation and the repeatability coefficients were better for the automated than manual measures. Conclusion: Although both methods are reliable for cIMT measurements, the automated technique allows faster evaluation with lesser variability for all carotid segments currently used in atherosclerosis research.
引用
收藏
页码:811 / 817
页数:7
相关论文
共 28 条
[1]   Peripheral vascular endothelial dysfunction and apoptosis in old monkeys [J].
Asai, K ;
Kudej, RK ;
Shen, YT ;
Yang, GP ;
Takagi, G ;
Kudej, AB ;
Geng, YJ ;
Sato, N ;
Nazareno, JB ;
Vatner, DE ;
Natividad, F ;
Bishop, SP ;
Vatner, SF .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2000, 20 (06) :1493-1499
[2]   Multi-ethnic study of atherosclerosis: Objectives and design [J].
Bild, DE ;
Bluemke, DA ;
Burke, GL ;
Detrano, R ;
Roux, AVD ;
Folsom, AR ;
Greenland, P ;
Jacobs, DR ;
Kronmal, R ;
Liu, K ;
Nelson, JC ;
O'Leary, D ;
Saad, MF ;
Shea, S ;
Szklo, M ;
Tracy, RP .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2002, 156 (09) :871-881
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   BENEFICIAL-EFFECTS OF COLESTIPOL-NIACIN THERAPY ON THE COMMON CAROTID-ARTERY - 2-YEAR AND 4-YEAR REDUCTION OF INTIMA-MEDIA THICKNESS MEASURED BY ULTRASOUND [J].
BLANKENHORN, DH ;
SELZER, RH ;
CRAWFORD, DW ;
BARTH, JD ;
LIU, CR ;
LIU, CH ;
MACK, WJ ;
ALAUPOVIC, P .
CIRCULATION, 1993, 88 (01) :20-28
[5]   Common carotid intima-media thickness and risk of stroke and myocardial infarction - The Rotterdam Study [J].
Bots, ML ;
Hoes, AW ;
Koudstaal, PJ ;
Hofman, A ;
Grobbee, DE .
CIRCULATION, 1997, 96 (05) :1432-1437
[6]  
Chambless LE, 1997, AM J EPIDEMIOL, V146, P483, DOI 10.1093/oxfordjournals.aje.a009302
[7]   Introduction to surrogate markers [J].
Cohn, JN .
CIRCULATION, 2004, 109 (25) :20-21
[8]   Distribution of ultrasonographically-assessed dimensions of common carotid arteries in healthy adults of both sexes [J].
Denarié, N ;
Gariepy, J ;
Chironi, G ;
Massonneau, M ;
Laskri, F ;
Salomon, J ;
Levenson, J ;
Simon, A .
ATHEROSCLEROSIS, 2000, 148 (02) :297-302
[9]   Risk factors for popliteal and carotid wall thicknesses in the Atherosclerosis Risk in Communities (ARIC) Study [J].
Dobs, AS ;
Nieto, FJ ;
Szklo, M ;
Barnes, R ;
Sharrett, AR ;
Ko, WJ .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1999, 150 (10) :1055-1067
[10]   THE CAROTID INTIMA-MEDIA THICKNESS ASA MARKER OF THE PRESENCE OF SEVERE SYMPTOMATIC CORONARY-ARTERY DISEASE [J].
GEROULAKOS, G ;
OGORMAN, DJ ;
KALODIKI, E ;
SHERIDAN, DJ ;
NICOLAIDES, AN .
EUROPEAN HEART JOURNAL, 1994, 15 (06) :781-785