A COMPARISON OF 2 VOLTAMMETRIC TECHNIQUES FOR DETERMINING ZINC SPECIATION IN NORTHEAST PACIFIC-OCEAN WATERS

被引:133
作者
DONAT, JR
BRULAND, KW
机构
[1] Institute of Marine Sciences, University of California, Santa Cruz
关键词
D O I
10.1016/0304-4203(90)90050-M
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Two independent voltammetric techniques, differential pulse cathodic stripping voltammetry (DPCSV) and differential pulse anodic stripping voltammetry (DPASV), determined that ≥ 95% of the dissolved zinc is organically complexed at two depths (60 and 150 m) within the surface euphotic zone at an open ocean station in the Northeast Pacific. Average values for the concentrations of the natural zinc-complexing organic ligands (CL) obtained from duplicate determinations at these two depths by DPCSV versus DPASV are in excellent agreement: 1.60 ± 0.01 versus 1.76 ± 0.03 nM at 60 m, and 2.14 (n=1) versus 2.22 ± 0.06 nM at 150 m. Average values for the conditional stability constants (with respect to free Zn2+) of the natural zinc-organic complexes (log K′ZnL) from duplicate determinations at both depths by DPCSV versus DPASV are 10.3 ± 0.2 versus 11.2 ± 0.2. Additional research is required to assess the significance of the difference in the conditional stability constants determined by these two techniques. These results confirm recent observations that strong zinc complexes formed with an organic ligand class existing at nanomolar concentrations dominates zinc speciation in the North Pacific. © 1990.
引用
收藏
页码:301 / 323
页数:23
相关论文
共 34 条
[1]   GROWTH LIMITATION OF A COASTAL DIATOM BY LOW ZINC ION ACTIVITY [J].
ANDERSON, MA ;
MOREL, FMM ;
GUILLARD, RRL .
NATURE, 1978, 276 (5683) :70-71
[2]  
ANDERSON RL, 1987, PRACTICAL STATISTICS
[3]   LIMITATION OF MARINE-PHYTOPLANKTON REPRODUCTIVE RATES BY ZINC, MANGANESE, AND IRON [J].
BRAND, LE ;
SUNDA, WG ;
GUILLARD, RRL .
LIMNOLOGY AND OCEANOGRAPHY, 1983, 28 (06) :1182-1198
[4]  
Bruland K.W., 1983, CHEM OCEANOGR, P157, DOI DOI 10.1016/B978-0-12-588608-6.50009-2
[5]   ANALYSIS OF SEAWATER FOR DISSOLVED CADMIUM, COPPER AND LEAD - AN INTERCOMPARISON OF VOLTAMMETRIC AND ATOMIC-ABSORPTION METHODS [J].
BRULAND, KW ;
COALE, KH ;
MART, L .
MARINE CHEMISTRY, 1985, 17 (04) :285-300
[7]  
BRULAND KW, 1979, ANAL CHIM ACTA, V105, P223
[8]   COPPER COMPLEXATION PROFILES IN THE ATLANTIC-OCEAN - A COMPARATIVE-STUDY USING ELECTROCHEMICAL AND ION-EXCHANGE TECHNIQUES [J].
BUCKLEY, PJM ;
VAN DEN BERG, CMG .
MARINE CHEMISTRY, 1986, 19 (03) :281-296
[9]   COPPER COMPLEXATION IN THE NORTHEAST PACIFIC [J].
COALE, KH ;
BRULAND, KW .
LIMNOLOGY AND OCEANOGRAPHY, 1988, 33 (05) :1084-1101
[10]   DIRECT DETERMINATION OF DISSOLVED COBALT AND NICKEL IN SEAWATER BY DIFFERENTIAL PULSE CATHODIC STRIPPING VOLTAMMETRY PRECEDED BY ADSORPTIVE COLLECTION OF CYCLOHEXANE-1,2-DIONE DIOXIME COMPLEXES [J].
DONAT, JR ;
BRULAND, KW .
ANALYTICAL CHEMISTRY, 1988, 60 (03) :240-244