MEASUREMENTS OF CARDIAC-OUTPUT AND ORGAN BLOOD-FLOW IN RATS USING TC-99M) LABELED MICROSPHERES

被引:20
作者
HAFSTROM, L
PERSSON, B
SUNDQVIST, K
机构
[1] UNIV LUND, DEPT SURG, S-22101 LUND, SWEDEN
[2] UNIV LUND, DEPT RADIAT PHYS, S-22101 LUND, SWEDEN
来源
ACTA PHYSIOLOGICA SCANDINAVICA | 1979年 / 106卷 / 02期
关键词
!sup]99[!/sup]Technetium[!sup]m[!/sup; blood flow; cardiac output; Microspheres;
D O I
10.1111/j.1748-1716.1979.tb06380.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The cardiac output and regional blood flow have been simultaneously determined in the anesthetized rat by using the reference organ method. 99Tcm labelled dextran 15 μm microspheres were injected in the left ventricle while simultaneously an arterial reference sample was drawn at constant known rate. The values calculated regarding cardiac output agree well with previously recorded series. Regional organ blood flow in the rat is presented as ml. min‐1. g‐1 tissue and values do agree with those reported by others. The results indicate that the reference organ method can be used in the rat for the study of cardiac output and regional blood flow. © 1979 Scandinavian Physiological Society
引用
收藏
页码:123 / 128
页数:6
相关论文
共 30 条
[1]   MEASUREMENT OF CARDIAC-OUTPUT WITH AND ORGAN TRAPPING OF RADIOACTIVE MICROSPHERES [J].
ARCHIE, JP ;
FIXLER, DE ;
ULLYOT, DJ ;
HOFFMAN, JIE ;
UTLEY, JR ;
CARLSON, EL .
JOURNAL OF APPLIED PHYSIOLOGY, 1973, 35 (01) :148-154
[2]   SIMPLE RADIOACTIVE MICROSPHERE METHOD FOR MEASURING REGIONAL FLOW AND CARDIAC-OUTPUT [J].
BARTRUM, RJ ;
BERKOWITZ, DM ;
HOLLENBERG, NK .
INVESTIGATIVE RADIOLOGY, 1974, 9 (03) :126-132
[3]  
BASSINGTHWAIGHTE J B, 1976, Seminars in Nuclear Medicine, V6, P141, DOI 10.1016/S0001-2998(76)80002-5
[4]   CARDIAC OUTPUT IN THE RAT AT NORMAL AND AT HIGH ALTITUDES AND ITS RELATIONSHIP TO GAS EMBOLISM [J].
BLOOD, FR ;
SMITH, DL ;
DAMOUR, FE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1950, 163 (02) :268-271
[5]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[6]  
BULLARD RW, 1956, FED PROC, V15, P28
[7]  
DARLE N, 1970, ACTA CHIR SCAND S407
[8]   TOTAL AND REGIONAL CORONARY BLOOD FLOW MEASURED BY RADIOACTIVE MICROSPHERES IN CONSCIOUS AND ANESTHETIZED DOGS [J].
DOMENECH, RJ ;
HOFFMAN, JIE ;
NOBLE, MIM ;
SAUNDERS, KB ;
HENSON, JR ;
SUBIJANTO, S .
CIRCULATION RESEARCH, 1969, 25 (05) :581-+
[9]   Studies on the circulation IV. Further analysis of the injection method, and of changes in hemodynamtcs under physiological and pathological conditions [J].
Hamilton, WF ;
Moore, JW ;
Kinsman, JM ;
Spurling, RG .
AMERICAN JOURNAL OF PHYSIOLOGY, 1932, 99 (03) :534-551
[10]   VALIDITY STUDIES OF RADIOACTIVE MICROSPHERE METHOD FOR STUDY OF DISTRIBUTION OF CARDIAC OUTPUT, ORGAN BLOOD FLOW, AND RESISTANCE IN CONSCIOUS RHESUS MONKEY [J].
HOFFBRAND, BI ;
FORSYTH, RP .
CARDIOVASCULAR RESEARCH, 1969, 3 (04) :426-+