Energetic evaluations of an electrochemical hydrogen compressor

被引:0
作者
Pineda-Delgado, J. L. [1 ]
Menchaca-Rivera, J. A. [1 ]
Perez-Robles, J. F. [1 ]
Aviles-Arellano, L. M. [1 ]
Chavez-Ramirez, A. U. [2 ]
Gutierrez B, Cynthia K. [2 ]
de Jesus Hernandez-Cortes, Ramiro [3 ]
Rivera, J. G. [3 ]
Rivas, S. [4 ]
机构
[1] Ctr Invest & Estudios Avanzados IPN, Campus Queret, Queretaro 76230, Mexico
[2] Ctr Invest & Desarrollo Tecnol Electroquim SC, Queretaro 76703, Mexico
[3] Univ Tecnol San Juan Rio, Div Ingn Quim & Energias Renovables, Queretaro 76800, Mexico
[4] Univ Autonoma Queretaro, Fac Ingn, Div Invest & Posgrad, Queretaro 76010, Mexico
关键词
Hydrogen; Electrochemical compressor; Efficiency; Potentiostatic; Galvanostatic;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Hydrogen has been considered as the energy vector that could narrow the gap in the transition towards less polluting energy production. However, it faces compression and storage as technological challenges. Electrochemical hydrogen compression (EHC) is an interesting alternative since it demands low power consumption and could even separate hydrogen from a gas mixture. Therefore, it is necessary to conduct an energetic evaluation of the EHC related to its working conditions to establish the optimal ones in terms of efficiency. This work presents the evaluation and comparison of galvanostatic and potentiostatic operation modes of an EHC with a 50-bar pressure target. During the development of the experimental work, the values of the main overpotentials that affect an EHC were obtained: diffusion voltage, membrane voltage, activation overpotential, and contact overpotential. The highest actual work and power values were achieved at 0.215 V and 0.5 A/cm(2) (potentiostatic and galvanostatic mode), while the lowest were obtained at 0.072 V and 0.1 A/cm(2). This trend is reversed for voltage efficiency, reaching a maximum of 69.7 % for 0.072 V and a minimum of 19.9 % for 0.5 A/cm(2). The calculated flow efficiency values were, for all cases, higher than 94 %, with a maximum efficiency of 99 % at operating conditions of 0.5 A/cm(2) and 0.215 V. The global efficiencies of the EHC were also calculated, being more efficient when working in a potentiostatic mode, presenting values of 66 % at 0.072 V against 52 % at 0.1 A/cm(2).
引用
收藏
页数:12
相关论文
共 52 条
  • [1] Risk changes of compound temperature and precipitation extremes in China under 1.5 °C and 2 °C global warming
    Aihaiti, Ailiyaer
    Jiang, Zhihong
    Zhu, Lianhua
    Li, Wei
    You, Qinglong
    [J]. ATMOSPHERIC RESEARCH, 2021, 264
  • [2] Anglo American, 2018, FUEL CELLS B, V2018, P12, DOI [10.1016/S1464-2859(18)30174-3, DOI 10.1016/S1464-2859(18)30174-3]
  • [3] [Anonymous], 2021, ITEM 1021 427 REPOSI
  • [4] [Anonymous], 115 NAFIONTM
  • [5] [Anonymous], 2011, FUEL CELLS B, V2011, P8, DOI [10.1016/S1464-2859(11)70283-8, DOI 10.1016/S1464-2859(11)70283-8]
  • [6] [Anonymous], 2021, FUEL CELLS B, V2021, P12, DOI [10.1016/S1464-2859(21)00043-2, DOI 10.1016/S1464-2859(21)00043-2]
  • [7] Effect of airbrush type on sprayed platinum and platinum-cobalt catalyst inks: Benchmarking as PEMFC and performance in an electrochemical hydrogen pump
    Arenas, Luis F.
    Hadjigeorgiou, Georgios
    Jones, Simon
    Van Dijk, Nick
    Hodgson, David
    Cruden, Andy
    de Leon, Carlos Ponce
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2020, 45 (51) : 27392 - 27403
  • [8] Barbir F, 2005, PEM FUEL CELLS, P1, DOI [10.1016/B978-012078142-3/50002-1, DOI 10.1016/B978-012078142-3/50002-1]
  • [9] Simultaneous electroosmotic and permeation flows through a Nafion membrane -: 2.: Methanol-water electrolyte solutions
    Barragán, VM
    Ruiz-Bauzá, C
    Villaluenga, JPG
    Seoane, B
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2005, 288 (02) : 540 - 547
  • [10] On the methanol-water electroosmotic transport in a Nafion membrane
    Barragán, VM
    Ruíz-Bauzá, C
    Villaluenga, JPG
    Seoane, B
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2004, 236 (01) : 109 - 120