IN-VIVO MEASUREMENT OF CHANGES IN BODY-COMPOSITION - DESCRIPTION OF METHODS AND THEIR VALIDATION AGAINST 12-D CONTINUOUS WHOLE-BODY CALORIMETRY

被引:59
作者
JEBB, SA
MURGATROYD, PR
GOLDBERG, GR
PRENTICE, AM
COWARD, WA
机构
[1] Dunn Clinical Nutrition Centre, Cambridge CB2 1Q1
关键词
BODY COMPOSITION; WHOLE-BODY CALORIMETRY; DENSITOMETRY; TOTAL BODY WATER; ANTHROPOMETRY; BIOIMPEDANCE AND RESISTANCE;
D O I
10.1093/ajcn/58.4.455
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
The accuracy of a variety of in vivo body-composition techniques (densitometry, total body water, skinfold thicknesses, whole-body impedance and resistance, body mass index, and two three-compartment models) was assessed by comparison with fat balance. Three subjects were overfed and three underfed while confined to a 30-m3 whole-body calorimeter continuously for 12 d. Mean weight changes were +2.90 kg during overfeeding and -3.47 kg during underfeeding. The change in fat mass accounted for 37.1% during overfeeding and 59.3% during underfeeding. In comparison with energy and nitrogen balance, a three-compartment model yielded the least bias and greatest precision. The smallest change in fat mass that can be measured by such a method in an individual subject is 1.54 kg (2 SD). Of the prediction techniques considered, skinfold thicknesses or the body-mass-index formula appear to be more precise than estimates based on resistance or impedance.
引用
收藏
页码:455 / 462
页数:8
相关论文
共 28 条
[1]   AN UNDERWATER WEIGHING SYSTEM UTILIZING FORCE CUBE TRANSDUCERS [J].
AKERS, R ;
BUSKIRK, ER .
JOURNAL OF APPLIED PHYSIOLOGY, 1969, 26 (05) :649-&
[2]   MEASUREMENT OF SHORT-TERM CHANGES IN THE FAT-CONTENT OF THE BODY - A COMPARISON OF 3 METHODS IN PATIENTS RECEIVING INTRAVENOUS NUTRITION [J].
ALMOND, DJ ;
KING, RFGJ ;
BURKINSHAW, L ;
OXBY, CB ;
MCMAHON, MJ .
BRITISH JOURNAL OF NUTRITION, 1984, 52 (02) :215-225
[3]  
BINGHAM SA, 1983, THESIS U CAMBRIDGE
[4]  
BLACK D, 1983, J R COLL PHYSICIANS, V17, P5
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   COMPARISON OF RADIO-OPAQUE PELLETS AND CHROMIUM SESQUIOXIDE AS INERT MARKERS IN STUDIES REQUIRING ACCURATE FECAL COLLECTIONS [J].
BRANCH, WJ ;
CUMMINGS, JH .
GUT, 1978, 19 (05) :371-376
[7]   ANALYSIS OF GASEOUS EXCHANGE IN OPEN-CIRCUIT INDIRECT CALORIMETRY [J].
BROWN, D ;
COLE, TJ ;
DAUNCEY, MJ ;
MARRS, RW ;
MURGATROYD, PR .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1984, 22 (04) :333-338
[8]  
COMROE JH, 1962, LUNG YEAR BOOK
[9]   BODY FAT ASSESSED FROM TOTAL-BODY DENSITY AND ITS ESTIMATION FROM SKINFOLD THICKNESS - MEASUREMENTS ON 481 MEN AND WOMEN AGED FROM 16 TO 72 YEARS [J].
DURNIN, JVGA ;
WOMERSLEY, J .
BRITISH JOURNAL OF NUTRITION, 1974, 32 (01) :77-97
[10]   THEORY AND VALIDITY OF INDIRECT CALORIMETRY DURING NET LIPID-SYNTHESIS [J].
ELIA, M ;
LIVESEY, G .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1988, 47 (04) :591-607