Evaluation of the Efficiency of Tc-99m-DMSA as a Radiopharmaceutical in Dynamic Renal Scans

被引:3
|
作者
Fahmy, Heba M. [1 ]
Yassin, Hossam M. [2 ]
Muhamed, Islam M. [1 ]
Mohamed, Samar E. [1 ]
Hassan, Shimaa S. [1 ]
机构
[1] Cairo Univ, Dept Biophys, Fac Sci, Cairo, Egypt
[2] Cairo Univ Hosp, Cairo, Egypt
关键词
Radiopharmaceutical; GFR; DMSA; DTPA; dynamic renal imaging; static renal imaging;
D O I
10.5152/etd.2018.0014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: In dynamic renal scans, Tc-99m-diethylenetriamine pentaacetic acid (DTPA) is copiously used and it yields information about the renal blood-flow and the excretory capacity. Tc-99m-dimercaptosuccinic acid (DMSA) is used for static renal imaging and can likewise uncover the renal cortical structure. This work was intended to evaluate whether DMSA can be declared as a radiopharmaceutical in dynamic renal scans or not. It also aimed at comparing the outcomes procured from DMSA and with DTPA examinations. Materials and Methods: A comparison of the information gained from the renograms of 47 subjects (normal subjects and subjects with abnormal renal function having: obstructive nephropathy, bilateral nephropathy, hydronephrosis, reduced or non-function kidney, and/or atrophic kidney) who had Tc-99m-DMSA and Tc-99m-DTPA dynamic scintigraphies utilizing the same protocol. Results: A strong positive correlation had come in view on the evaluation of the left kidney, right kidney, and total glomerular filtration rate (GFR) from Tc-99m-DTPA and Tc-99m-DMSA renograms. In addition, the estimation of the time of the peak height from Tc-99m-DTPA and Tc-99m-DMSA renograms for the right and left kidneys demonstrated as non-significant varieties and a strong positive correlation for both the normal subjects and subjects with kidney abnormalities. Conclusion: In the light of the outcomes gained from the present investigation, it could be prescribed that Tc-99m-DMSA can favorably replace Tc-99m-DTPA in dynamic renograms in the case of the renal conditions that had been examined in the present work. As scheduled, this will be cost-effective and time saving and will decrease the radiation dose administered to the subjects. Also, the same qualities of results are accomplished with both radiopharmaceuticals in normal subjects and subjects with abnormal renal function.
引用
收藏
页码:140 / 147
页数:8
相关论文
共 49 条
  • [21] In Vitro Evaluation of Tc-99m Radiopharmaceuticals for Gastric Emptying Studies
    Ertay, Turkan
    Dogan, Amet Semih
    Ulker, Ozden
    Durak, Hatice
    MOLECULAR IMAGING AND RADIONUCLIDE THERAPY, 2014, 23 (01) : 21 - 24
  • [22] Quality Assessment of Tc-99m Methylene Diphosphonate (MDP) Radiopharmaceutical Prepared Using Different Cold Kit Fractionation Methods
    Thokchom, Arun Kumar
    Kumar, Rajesh
    Bharati, Sanjay
    Vasumathi, Vasumathi
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2022, 37 (01): : 7 - 11
  • [23] Technetium-99m complex of N-(2-pyridylmethyl)iminodiacetic acid as a new renal radiopharmaceutical
    Karube, Y
    Iwamoto, K
    Takata, J
    ANNALS OF NUCLEAR MEDICINE, 1999, 13 (02) : 127 - 132
  • [24] Technetium-99m complex ofN-(2-pyridylmethyl)iminodiacetic acid as a new renal radiopharmaceutical
    Yoshiharu Karube
    Koji Iwamoto
    Jiro Takata
    Annals of Nuclear Medicine, 1999, 13 : 127 - 132
  • [25] [18F]PSMA-1007 PET is comparable to [99mTc]Tc-DMSA SPECT for renal cortical imaging
    Kristian Valind
    David Minarik
    Sabine Garpered
    Eva Persson
    Jonas Jögi
    Elin Trägårdh
    European Journal of Hybrid Imaging, 7
  • [26] [18F]PSMA-1007 PET is comparable to [99mTc]Tc-DMSA SPECT for renal cortical imaging
    Valind, Kristian
    Minarik, David
    Garpered, Sabine
    Persson, Eva
    Jogi, Jonas
    Tragardh, Elin
    EUROPEAN JOURNAL OF HYBRID IMAGING, 2023, 7 (01):
  • [27] Comparison of differential renal function using technetium-99m mercaptoacetyltriglycine (MAG3) and technetium-99m dimercaptosuccinic acid (DMSA) renography in a paediatric population
    Gillian Ritchie
    Alistair G. Wilkinson
    Robin J. Prescott
    Pediatric Radiology, 2008, 38 : 857 - 862
  • [28] Comparison of differential renal function using technetium-99m mercaptoacetyltriglycine (MAG3) and technetium-99m dimercaptosuccinic acid (DMSA) renography in a paediatric population
    Ritchie, Gillian
    Wilkinson, Alistair G.
    Prescott, Robin J.
    PEDIATRIC RADIOLOGY, 2008, 38 (08) : 857 - 862
  • [29] GFR MEASURING WITH TC-99M-DTPA - LIMITS IN OBSTRUCTIVE ACUTE-RENAL-FAILURE
    SALERNO, L
    CURIALE, B
    PEPE, S
    CORRAO, S
    MIRABILE, D
    PANMINERVA MEDICA, 1991, 33 (01) : 30 - 34
  • [30] The defection of vesicoureteral reflux in a nonfunctioning kidney on a Tc-99m DTPA renal function study
    Kibar, M
    Dogruca, Z
    Buyukdereli, G
    Noyan, A
    Onsel, C
    CLINICAL NUCLEAR MEDICINE, 1998, 23 (02) : 108 - 110