Evaluation of the Efficiency of Tc-99m-DMSA as a Radiopharmaceutical in Dynamic Renal Scans

被引:3
|
作者
Fahmy, Heba M. [1 ]
Yassin, Hossam M. [2 ]
Muhamed, Islam M. [1 ]
Mohamed, Samar E. [1 ]
Hassan, Shimaa S. [1 ]
机构
[1] Cairo Univ, Dept Biophys, Fac Sci, Cairo, Egypt
[2] Cairo Univ Hosp, Cairo, Egypt
关键词
Radiopharmaceutical; GFR; DMSA; DTPA; dynamic renal imaging; static renal imaging;
D O I
10.5152/etd.2018.0014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: In dynamic renal scans, Tc-99m-diethylenetriamine pentaacetic acid (DTPA) is copiously used and it yields information about the renal blood-flow and the excretory capacity. Tc-99m-dimercaptosuccinic acid (DMSA) is used for static renal imaging and can likewise uncover the renal cortical structure. This work was intended to evaluate whether DMSA can be declared as a radiopharmaceutical in dynamic renal scans or not. It also aimed at comparing the outcomes procured from DMSA and with DTPA examinations. Materials and Methods: A comparison of the information gained from the renograms of 47 subjects (normal subjects and subjects with abnormal renal function having: obstructive nephropathy, bilateral nephropathy, hydronephrosis, reduced or non-function kidney, and/or atrophic kidney) who had Tc-99m-DMSA and Tc-99m-DTPA dynamic scintigraphies utilizing the same protocol. Results: A strong positive correlation had come in view on the evaluation of the left kidney, right kidney, and total glomerular filtration rate (GFR) from Tc-99m-DTPA and Tc-99m-DMSA renograms. In addition, the estimation of the time of the peak height from Tc-99m-DTPA and Tc-99m-DMSA renograms for the right and left kidneys demonstrated as non-significant varieties and a strong positive correlation for both the normal subjects and subjects with kidney abnormalities. Conclusion: In the light of the outcomes gained from the present investigation, it could be prescribed that Tc-99m-DMSA can favorably replace Tc-99m-DTPA in dynamic renograms in the case of the renal conditions that had been examined in the present work. As scheduled, this will be cost-effective and time saving and will decrease the radiation dose administered to the subjects. Also, the same qualities of results are accomplished with both radiopharmaceuticals in normal subjects and subjects with abnormal renal function.
引用
收藏
页码:140 / 147
页数:8
相关论文
共 49 条
  • [1] A KINETIC-MODEL FOR TC-99M-DMSA IN THE RAT
    MANEVAL, DC
    DARGENIO, DZ
    WOLF, W
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1990, 16 (01): : 29 - 34
  • [2] Inter- and Intraobserver Variability of Tc-99m-DMSA Renal Scintigraphy: Impact of Oblique Views
    Caglar, Meltem
    Kiratli, Pinar Ozgen
    Karabulut, Erdem
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2007, 35 (02) : 96 - 99
  • [3] Tc-99m DMSA and Tc-99m MAG3 findings in crossed renal ectopia
    Jimenez-Heffernan, A
    Rebollo, AC
    Garcia-Martin, M
    Herrera, C
    Acosta, J
    CLINICAL NUCLEAR MEDICINE, 1998, 23 (04) : 255 - 255
  • [4] A study of child movement during Tc-99(m) DMSA renal imaging procedures
    Meadows, A. V.
    Hogg, P.
    RADIOGRAPHY, 2006, 12 (03) : 225 - 235
  • [5] 3-D display of Tc-99m DMSA SPECT in crossed fused renal ectopia
    Harvey, CJ
    Buscombe, JR
    Hilson, AJW
    CLINICAL NUCLEAR MEDICINE, 1998, 23 (06) : 399 - 401
  • [6] Tc-99m-Mercaptoacetyltriglycine and Tc-99m-Dimercaptosuccinic Acid Scintigraphies for the Evaluation of Renal Parenchymal Lesions in Infants
    Yaylali, Olga
    Kirac, Fatma Suna
    Yuksel, Dogangun
    Kilic, Ilknur
    TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2009, 29 (05): : 1206 - 1211
  • [7] TC(99M)-DMSA IMAGING WITH TOMOGRAPHY IN RENAL-TRANSPLANT RECIPIENTS WITH ABNORMAL LOWER URINARY TRACTS
    CAIRNS, HS
    SPENCER, S
    HILSON, AJW
    RUDGE, CJ
    NEILD, GH
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1994, 9 (08) : 1157 - 1161
  • [8] Evaluation of interobserver variability of parenchyma phase of Tc-99m mercaptoacetyltriglycine and Tc-99m dimercaptosuccinic acid renal scintigraphy
    Erdogan, Zeynep
    Abdulrezzak, Ummuhan
    Silov, Guler
    Ozdal, Aysegul
    Turhal, Ozgul
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2014, 29 (02): : 87 - 91
  • [9] Diagnostic accuracy of Tc-99m DMSA scintigraphy and renal ultrasonography for detecting renal scarring and relative function in patients with spinal dysraphism
    Veenboer, Paul W.
    Hobbelink, Monique G. G.
    Bosch, J. L. H. Ruud
    Dik, Pieter
    van Asbeck, Floris W. A.
    Beek, Frederik J. A.
    de Kort, Laetitia M. O.
    NEUROUROLOGY AND URODYNAMICS, 2015, 34 (06) : 513 - 518
  • [10] Pentavalent Tc-99m DMSA: Uptake into a variety of human rhabdomyosarcoma xenografts
    VanderWall, H
    Henderson, D
    Baker, R
    Murray, IPC
    IN VIVO, 1997, 11 (01): : 45 - 50