DETERMINATION OF (22R,S)BUDESONIDE IN HUMAN PLASMA BY AUTOMATED LIQUID-CHROMATOGRAPHY THERMOSPRAY MASS-SPECTROMETRY

被引:34
作者
LINDBERG, C
BLOMQVIST, A
PAULSON, J
机构
[1] Astra Draco AB, Lund, S-221 00
关键词
D O I
10.1002/bms.1200211102
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
(22R,S)Budesonide was isolated from human plasma by solid-phase extraction. Switching from reversed-phase conditions during sample application and washing to normal-phase conditions during elution afforded a very clean extract. Budesonide was derivatized with acetic anhydride to form the 21-acetyl derivative before analysis by reversed-phase liquid chromatography combined with thermospray mass spectrometry. Deuterium-labelled budesonide was used as internal standard. Standard samples prepared in human albumin solution were used for the calibration curve. An automated liquid chromatography/mass spectrometry system, allowing unattended overnight operation, was used for routine analysis. The recovery of budesonide from plasma was 88.9 +/- 5.9% (mean +/- SD) and the method was linear over the range 0.30-30 pmol (amount analysed), corresponding to plasma concentrations of 0.10-10 nmol l-1. Budesonide could be measured down to 0.10 nmol l-1 with a within-day variation of 10-18% (CV). The error was less than +/- 15% at 0.10 nmol l-1 and less than +/- 7% at concentrations of 0.20 nmol l-1 or higher. The total imprecision between days was 9% (CV) at a concentration of 0.30 amol l-1.
引用
收藏
页码:525 / 533
页数:9
相关论文
共 17 条
[1]   A SENSITIVE RADIOIMMUNOASSAY FOR BUDESONIDE IN PLASMA [J].
AHERNE, GW ;
LITTLETON, P ;
THALEN, A ;
MARKS, V .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 1982, 17 (05) :559-565
[2]  
Berg Erez., COMMUNICATION
[3]   BUDESONIDE - A PRELIMINARY REVIEW OF ITS PHARMACODYNAMIC PROPERTIES AND THERAPEUTIC EFFICACY IN ASTHMA AND RHINITIS [J].
CLISSOLD, SP ;
HEEL, RC .
DRUGS, 1984, 28 (06) :485-518
[4]   DIRECT LIQUID INTRODUCTION THERMOSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
COVEY, T ;
HENION, J .
ANALYTICAL CHEMISTRY, 1983, 55 (14) :2275-2280
[5]   NASAL BIOAVAILABILITY AND SYSTEMIC EFFECTS OF THE GLUCOCORTICOID BUDESONIDE IN MAN [J].
EDSBACKER, S ;
ANDERSSON, KE ;
RYRFELDT, A .
EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1985, 29 (04) :477-481
[6]  
EDSBACKER S, 1987, DRUG METAB DISPOS, V15, P403
[7]  
EDSBACKER S, 1987, DRUG METAB DISPOS, V15, P412
[8]   THERMOSPRAY HPLC/MS - A NEW MASS-SPECTROMETRIC TECHNIQUE FOR THE PROFILING OF STEROIDS [J].
LIBERATO, DJ ;
YERGEY, AL ;
ESTEBAN, N ;
GOMEZSANCHEZ, CE ;
SHACKLETON, CHL .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 1987, 27 (1-3) :61-70
[9]   EVALUATION OF AN AUTOMATED THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY SYSTEM FOR QUANTITATIVE USE IN BIOANALYTICAL CHEMISTRY [J].
LINDBERG, C ;
PAULSON, J ;
BLOMQVIST, A .
JOURNAL OF CHROMATOGRAPHY, 1991, 554 (1-2) :215-226
[10]   THE USE OF ONLINE LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY AND STABLE ISOTOPE TECHNIQUES FOR THE IDENTIFICATION OF BUDESONIDE METABOLITES [J].
LINDBERG, C ;
PAULSON, J ;
EDSBACKER, S .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1987, 14 (10) :535-541