Realistic Head Phantom for Evaluation of Brain Stroke Localization Methods Using 3D Printer

被引:11
|
作者
Lee, Juneseok [1 ]
Bang, Jihoon [1 ]
Choi, Jaehoon [1 ]
机构
[1] Hanyang Univ, Dept Elect & Comp Engn, Seoul, South Korea
关键词
Brain; Phantom; Stroke Localization; 3D Printer;
D O I
10.5515/JKIEES.2016.16.4.254
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a brain phantom for evaluating brain stroke localization is proposed. To evaluate brain stroke localization, a phantom imitating three-dimensional (3D) simulation environment is needed. Mold for the proposed phantom was printed by a 3D printer and the interior of the phantom consists of 5 different brain tissue materials. Each of the brain tissue materials has the conductivity and permittivity similar to those of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) standards for a frequency band from 0.5 to 2 GHz.
引用
收藏
页码:254 / 258
页数:5
相关论文
共 50 条
  • [31] 3D flow study in a mildly stenotic coronary artery phantom using a whole volume PIV method
    Brunette, J.
    Mongrain, R.
    Laurier, J.
    Galaz, R.
    Tardif, J. C.
    MEDICAL ENGINEERING & PHYSICS, 2008, 30 (09) : 1193 - 1200
  • [32] Temporal and Spatial Calibration of a freehand 3D ultrasound reconstructions system by using an N-wire phantom
    Mathieu, Bielmann
    Claire, Closset
    Lorenzo, Leija
    Arturo, Vera
    2015 12TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, COMPUTING SCIENCE AND AUTOMATIC CONTROL (CCE 2015), 2015,
  • [33] Monte Carlo Simulation of Liver Dosimetry with Yttrium-90 Radionuclide Using Gate: 3D Phantom
    Karadeniz-Yildirim, Ayse
    Ozkorucuklu, Suat
    Tanyildizi-Kokkulunk, Handan
    Demir, Mustafa
    Yasar, Dogan
    BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2024, 51 (01) : 30 - 37
  • [34] Evaluation of an integrated 3D-printed phantom for coronary CT angiography using iterative reconstruction algorithm
    Abdullah, Kamarul A.
    McEntee, Mark F.
    Reed, Warren
    Kench, Peter L.
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2020, 67 (03) : 170 - 176
  • [35] Evaluation of a semi-automatic segmentation algorithm in 3D intraoperative ultrasound brain angiography
    Chalopin, Claire
    Krissian, Karl
    Meixensberger, Juergen
    Muens, Andrea
    Arlt, Felix
    Lindner, Dirk
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58 (03): : 293 - 302
  • [36] 3D evaluation of 3DVH program using BANG3 polymer gel dosimeter
    Watanabe, Yoichi
    Nakaguchi, Yuji
    MEDICAL PHYSICS, 2013, 40 (08)
  • [37] 3D brain magnetic resonance imaging segmentation by using bitplane and adaptive fast marching
    Tran Anh Tuan
    Kim, Jin Young
    Pham The Bao
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2018, 28 (03) : 223 - 230
  • [38] In vivo bioimpedance changes during haemorrhagic and ischaemic stroke in rats: towards 3D stroke imaging using electrical impedance tomography
    Dowrick, T.
    Blochet, C.
    Holder, D.
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (06) : 765 - 784
  • [39] 3D CNN Design for the Classification of Alzheimer's Disease Using Brain MRI and PET
    Khagi, Bijen
    Kwon, Goo-Rak
    IEEE ACCESS, 2020, 8 : 217830 - 217847
  • [40] Evaluation of 3D-CRT Radiotherapy Treatment Planning with Radiobiological Effects in Patient-Specific 3D Printed Anthropomorphic Phantom Postmastectomy Breast Cancer Axillary Metastases
    Endarko, Endarko
    Hariyanto, Aditya Prayugo
    Aisyah, Siti
    Kavilani, Nandia
    Syafi’i, Ahmad
    Iranian Journal of Medical Physics, 2024, 21 (05) : 314 - 322