Realistic Head Phantom for Evaluation of Brain Stroke Localization Methods Using 3D Printer

被引:11
|
作者
Lee, Juneseok [1 ]
Bang, Jihoon [1 ]
Choi, Jaehoon [1 ]
机构
[1] Hanyang Univ, Dept Elect & Comp Engn, Seoul, South Korea
关键词
Brain; Phantom; Stroke Localization; 3D Printer;
D O I
10.5515/JKIEES.2016.16.4.254
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a brain phantom for evaluating brain stroke localization is proposed. To evaluate brain stroke localization, a phantom imitating three-dimensional (3D) simulation environment is needed. Mold for the proposed phantom was printed by a 3D printer and the interior of the phantom consists of 5 different brain tissue materials. Each of the brain tissue materials has the conductivity and permittivity similar to those of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) standards for a frequency band from 0.5 to 2 GHz.
引用
收藏
页码:254 / 258
页数:5
相关论文
共 50 条
  • [21] Step-by-step of 3D printing a head-and-neck phantom: Proposal of a methodology using fused filament fabrication (FFF) technology
    Savi, M.
    Villani, D.
    Andrade, B.
    Soares, F. A. P.
    Rodrigues Jr, O.
    Campos, L. L.
    Potiens, M. P. A.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 223
  • [22] Technical Note: Development of a 3D printed subresolution sandwich phantom for validation of brain SPECT analysis
    Negus, Ian S.
    Holmes, Robin B.
    Jordan, Kirsty C.
    Nash, David A.
    Thorne, Gareth C.
    Saunders, Margaret
    MEDICAL PHYSICS, 2016, 43 (09) : 5020 - 5027
  • [23] Using 3D printing techniques to create an anthropomorphic thorax phantom for medical imaging purposes
    Hazelaar, Colien
    van Eijnatten, Maureen
    Dahele, Max
    Wolff, Jan
    Forouzanfar, Tymour
    Slotman, Ben
    Verbakel, Wilko F. A. R.
    MEDICAL PHYSICS, 2018, 45 (01) : 92 - 100
  • [24] Evaluation of 3D printable rubber-elastomeric polymer as phantom material for Hybrid PET/MRI
    Talalwa, Lotfi
    Gordji-Nejad, Ali
    Natour, Ghaleb
    Drzezga, Alexander
    Bauer, Andreas
    Beer, Simone
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [25] Evaluation of cortical superficial siderosis in patients with cognitive dysfunction using 3D FLAIR and 3D DIR
    Umino, Maki
    Maeda, Masayuki
    Kogue, Ryota
    Nakamura, Satoshi
    Ii, Yuichiro
    Tomimoto, Hidekazu
    Sakuma, Hajime
    EUROPEAN RADIOLOGY, 2021, 31 (09) : 6411 - 6418
  • [26] Evaluation of cortical superficial siderosis in patients with cognitive dysfunction using 3D FLAIR and 3D DIR
    Maki Umino
    Masayuki Maeda
    Ryota Kogue
    Satoshi Nakamura
    Yuichiro Ii
    Hidekazu Tomimoto
    Hajime Sakuma
    European Radiology, 2021, 31 : 6411 - 6418
  • [27] Spatial normalization of 3D brain images using deformable models
    Davatzikos, C
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (04) : 656 - 665
  • [28] Rapid acquisition of the 3D MRI gradient impulse response function using a simple phantom measurement
    Rahmer, Juergen
    Mazurkewitz, Peter
    Boernert, Peter
    Nielsen, Tim
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (06) : 2146 - 2159
  • [29] Arthroscope Localization in 3D Ultrasound Volumes Using Weakly Supervised Deep Learning
    van der Burgt, Jeroen M. A.
    Camps, Saskia M.
    Antico, Maria
    Carneiro, Gustavo
    Fontanarosa, Davide
    APPLIED SCIENCES-BASEL, 2021, 11 (15):
  • [30] Monte Carlo Simulation of Liver Dosimetry with Yttrium-90 Radionuclide Using Gate: 3D Phantom
    Ayşe Karadeniz-Yildirim
    Suat Ozkorucuklu
    Handan Tanyildizi-Kokkulunk
    Mustafa Demir
    Dogan Yasar
    Bulletin of the Lebedev Physics Institute, 2024, 51 : 30 - 37