摘要
This study was performed to investigate whether intravenous administration of Gd-DTPA can improve the accuracy of MR imaging in the detection and staging of bladder neoplasms. In 68 patients with suspected urinary bladder neoplasms, MR examinations were performed with TI-weighted SE sequences before and after intravenous administration of Gd-DTPA. The findings were compared with surgical staging using the TNM classification. Overall staging accuracy of contrast enhanced MR was 46%; if stages Ta-T3a were combined into one group, the accuracy was 69%. Accuracy was low (19%) in tumors without muscular bladder wall invasion (Ta). In cases with extravesical spread (greater-than-or-equal-to T3b), the accuracy of staging was 87%. Contrast enhanced MR detected extravesical extension of tumor with a sensitivity of 93% and a specificity of 95%. Contrast enhancement increased the sensitivity for detection of urinary bladder neoplasms from 70% on precontrast TI-weighted scans to 79% on postcontrast scans. In comparison with T2-weighted scans, the Gd-DTPA enhanced T1-weighted scans had better image quality and lower acquisition times.
引用
收藏
页码:780 / 786
页数:7
相关论文
共 50 条
  • [31] IN-VIVO F-19 MR-IMAGING - RELAXATION ENHANCEMENT WITH GD-DTPA
    LEE, H
    PRICE, RR
    HOLBURN, GE
    PARTAIN, CL
    ADAMS, MD
    CACHERIS, WP
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (04): : 609 - 613
  • [32] MYOCARDIAL INFARCT SIZE AFTER REPERFUSION THERAPY - ASSESSMENT WITH GD-DTPA ENHANCED MR IMAGING
    DEROOS, A
    MATHEIJSSEN, NAA
    DOORNBOS, J
    VANDIJKMAN, PRM
    VANVOORTHUISEN, AE
    VANDERWALL, EE
    RADIOLOGY, 1990, 176 (02) : 517 - 521
  • [33] RENAL MASSES - EVALUATION WITH GRADIENT-ECHO GD-DTPA ENHANCED DYNAMIC MR IMAGING
    EILENBERG, SS
    LEE, JKT
    BROWN, JJ
    MIROWITZ, SA
    TARTAR, VM
    RADIOLOGY, 1990, 176 (02) : 333 - 338
  • [34] DOUBLE-CONTRAST MR-IMAGING WITH IRON COLLOID AND GD-DTPA IN CHOLANGIOCELLULAR CARCINOMA
    SUTO, Y
    SHIMATANI, Y
    KATO, T
    KAMBA, M
    OHUCHI, Y
    KODAMA, F
    KATO, T
    OHTA, Y
    ACTA RADIOLOGICA, 1994, 35 (06) : 632 - 633
  • [35] Apparent diffusion coefficient measurements and Gd-DTPA enhanced-imaging in staging hepatic fibrosis in rats
    Zhao, Yi-Ping
    Guo, Dong-Mei
    Liu, Hui
    Liu, Wen-Hong
    Mu, Wen-Ying
    Zhang, Peng
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (02): : 2197 - 2204
  • [36] IN-VIVO QUANTIFICATION OF THE UNIDIRECTIONAL INFLUX CONSTANT FOR GD-DTPA DIFFUSION ACROSS THE MYOCARDIAL CAPILLARIES WITH MR-IMAGING
    LARSSON, HBW
    STUBGAARD, M
    SONDERGAARD, L
    HENRIKSEN, O
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03) : 433 - 440
  • [37] CRANIOSPINAL MAGNETIC-RESONANCE-IMAGING ENHANCED WITH GD-DTPA IN VONHIPPEL-LINDAU DISEASE
    HARDJASUDARMA, M
    FOWLER, M
    JOURNAL OF THE CANADIAN ASSOCIATION OF RADIOLOGISTS-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1991, 42 (04): : 283 - 286
  • [38] INVIVO MR EVALUATION OF GD-DTPA CONJUGATED TO DEXTRAN IN NORMAL RABBITS
    LI, KCP
    QUISLING, RG
    ARMITAGE, FE
    RICHARDSON, D
    MLADINICH, C
    MAGNETIC RESONANCE IMAGING, 1992, 10 (03) : 439 - 444
  • [39] Magnetic resonance imaging in patients with central nervous system pathology: A comparison of OptiMARK (Gd-DTPA-BMEA) and Magnevist (Gd-DTPA)
    Grossman, RI
    Rubin, DL
    Hunter, G
    Haughton, VM
    Lee, D
    Sze, G
    Kuhn, MJ
    Maravilla, K
    Tu, R
    Heindel, W
    Wippold, FJ
    Leeds, N
    Zelch, J
    Jinkins, JR
    Grodd, W
    Truwit, C
    Kanal, E
    Provenzale, JM
    Ramsey, R
    Simon, J
    Brunberg, JA
    Stevens, GR
    Kristy, RM
    INVESTIGATIVE RADIOLOGY, 2000, 35 (07) : 412 - 419
  • [40] Phantom and animal studies of a new hepatobiliary agent for MR imaging: Comparison of Gd-DTPA-DeA with Gd-EOB-DTPA
    Yoshikawa, K
    Inoue, Y
    Akahane, M
    Shimada, M
    Itoh, S
    Seno, A
    Hayashi, S
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (02) : 204 - 209