Vibration Control in a 101-Storey Building Using a Tuned Mass Damper

被引:72
作者
Tuan, Alex Y. [1 ]
Shang, G. Q. [2 ]
机构
[1] Tamkang Univ, Dept Civil Engn, Tamsui 251, Taiwan
[2] City Univ Hong Kong, Dept Civil & Architectural Engn, Hong Kong, Hong Kong, Peoples R China
来源
JOURNAL OF APPLIED SCIENCE AND ENGINEERING | 2014年 / 17卷 / 02期
关键词
Vibration Control; Tuned Mass Damper (TMD); Structure-TMD Interaction; Dynamic Analysis; Wind Effect; Earthquake Excitation; FEM; Wind Tunnel Testing; Field Measurement;
D O I
10.6180/jase.2014.17.2.05
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study investigates the mitigating effects of a TMD on the structural dynamic responses of Taipei 101 Tower, under the action of winds and remote (long-distance) seismic excitation. To begin with, the optimal parameters of the TMD in Taipei 101 Tower are first determined. Then a finite element model of this high-rise building, equipped with a TMD system, is established. A detailed dynamic analysis is conducted accordingly, to evaluate the behavior of the structure-TMD system. The simulation results obtained are compared with the wind tunnel test data and the recorded field measurements. The accuracy of the established computational frameworks is then verified. Findings of this study demonstrate that the use of the TMD in this building is materially effective in reducing the wind-induced vibrations. However, it is not as effective in mitigating remote seismic vibrations responses.
引用
收藏
页码:141 / 156
页数:16
相关论文
共 22 条
[1]  
[Anonymous], 1999, WIND IND STRUCT RESP
[2]   MINIMIZING STRUCTURAL VIBRATIONS WITH ABSORBERS [J].
AYORINDE, EO ;
WARBURTON, GB .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1980, 8 (03) :219-236
[3]   Response of tall buildings to weak long distance earthquakes [J].
Brownjohn, JMW ;
Pan, TC .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2001, 30 (05) :709-729
[4]   Mass dampers and their optimal designs for building vibration control [J].
Chang, CC .
ENGINEERING STRUCTURES, 1999, 21 (05) :454-463
[5]  
Den Hartog J.P., 1985, MECH VIBRATIONS
[6]   Wind tunnel study of the across-wind response of a slender tower with a nonlinear tuned mass damper [J].
Gerges, RR ;
Vickery, BJ .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2003, 91 (08) :1069-1092
[7]  
Huang SH, 2010, WIND STRUCT, V13, P557
[8]  
International Standards OrganizationWind Load Committee, 1987, 98SC3WG2 ISO TC
[9]  
Kareem A., 1999, WIND STRUCT INT J, V2, P201, DOI [10.12989/was.1999.2.3.201, DOI 10.12989/WAS.1999.2.3.201]
[10]  
Korenev BG., 1993, DYNAMIC VIBRATION AB