BASIS FOR NONDESTRUCTIVE INDUCTION CONTROL OF WINDING INSULATION OF ELECTRICAL MACHINES

被引:0
|
作者
Smirnov, Gennadiy, V [1 ]
Smirnov, Dmitriy G. [1 ]
机构
[1] Tomsk State Univ Control Syst & Radioelect, 40 Lenin Ave, Tomsk 634045, Russia
关键词
Enamel insulation; defect; defect sensor; induction; leads generator; potential; pulse of defect; length; frequency; speed sensor;
D O I
暂无
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The relevance of the work is caused by the fact that electric machines are used in most production processes of various industries. The failure of the electrical machine leads to a crash, shutdown and consequently to high economic cost to elimination of the results of machine failure. The results of electric machines failure is especially tangible in exploration, production and transportation of geo-resources in oil, mining, coal, chemical and other industries, as these industries are the basis of budget formation now. The reliability and safety of these machines depend on condition of winding insulation, i.e. the enamel insulation of winding wires. Thus improving control of the enamel insulation of winding wires, their quality is the critical issue. The aim of the research is to study the possibility of using electromagnetic induction for non-destructive testing of enamel insulation of winding wires. Research methods: electromagnetic, for generating and studying the characteristics of a signal of contact defects transducer; micrometer, to determine the geometrical sizes of defects in enamel insulation and to match them with the control results. Results. The authors have studied the possibility of using contact sensors of defects for controlling insulation of winding wires when using the induced EMF as a signal in the controlled wire conductor. The authors developed the method of controlling the defects in enamel insulation of wires to determine the number and length of defective areas of wire moving with any variable speed in it. The scheme of defects meter was proposed and the principle of its work was considered. The authors identified the systematic error when controlling the defects length caused by the finite size of the defect sensor. The paper introduces the method of its elimination.
引用
收藏
页码:24 / 36
页数:13
相关论文
共 50 条
  • [21] Basis for Local Methods of Insulation Hardening of Traction Rolling Stock Electrical Machines
    Khudonogov, Anatoliy
    Dulskiy, Evgeny
    Ivanov, Pavel
    INTERNATIONAL SCIENTIFIC CONFERENCE ENERGY MANAGEMENT OF MUNICIPAL TRANSPORTATION FACILITIES AND TRANSPORT, EMMFT 2017, 2018, 692 : 109 - 119
  • [22] Corona free winding in electrical machines
    Asokan, T
    CONFERENCE RECORD OF THE 2004 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2004, : 222 - 225
  • [23] MEASURING WINDING TEMPERATURES FOR ELECTRICAL MACHINES
    GRIBAKIN, VS
    GRIBAKIN, AS
    BARASHEV, AF
    EIDELMAN, GI
    MEASUREMENT TECHNIQUES USSR, 1990, 33 (10): : 1019 - 1022
  • [24] Electrical and thermal processes of HEV induction machines taking into account stator winding form
    Grachev, Pavel Yu.
    Bazarov, Aleksandr A.
    Tabachinskiy, Aleksey S.
    2017 XI INTERNATIONAL IEEE SCIENTIFIC AND TECHNICAL CONFERENCE DYNAMICS OF SYSTEMS, MECHANISMS AND MACHINES (DYNAMICS), 2017,
  • [25] Electrical Degradation Study of Machine Winding Insulation
    Grzybowski, S.
    Taylor, C. D.
    Chalise, S. R.
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 321 - 325
  • [26] Accelerated Electrical Degradation of Machine Winding Insulation
    Chalise, S. R.
    Grzybowski, S.
    Taylor, C. D.
    2009 IEEE ELECTRIC SHIP TECHNOLOGIES SYMPOSIUM, 2009, : 527 - 532
  • [27] Electrical Insulation Tape Winding and Inspection System
    Petrella, Joseph R., Jr.
    D'Agostino, Michael J.
    Cropper, Mark
    Guttenfelder, Jessica
    FUSION SCIENCE AND TECHNOLOGY, 2019, 75 (08) : 810 - 814
  • [28] Survey of Insulation Systems in Electrical Machines
    Hemmati, Rasul
    Wu, Fan
    EL-Refaie, Ayman
    2019 IEEE INTERNATIONAL ELECTRIC MACHINES & DRIVES CONFERENCE (IEMDC), 2019, : 2069 - 2076
  • [29] Fillers in Insulation for Rotating Electrical Machines
    Wilder, Aleta T.
    Neves, R. Scott
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (05) : 1357 - 1363
  • [30] Insulation evaluation for electrical rotating machines
    Zhou, YF
    Dix, GI
    Quaife, PW
    IEEE 1996 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I & II, 1996, : 537 - 540