Haemodynamic response at double lumen bronchial tube placement Airtraq vs. MacIntosh laryngoscope, a randomised controlled trial

被引:0
|
作者
Hamp, Thomas [1 ]
Stumpner, Thomas [1 ]
Grubhofer, Georg [1 ]
Ruetzler, Kurt [1 ]
Thell, Rainer [1 ]
Hager, Helmut [1 ]
机构
[1] Med Univ Vienna, Dept Cardiothorac & Vasc Anaesthesia & Intens Car, Waehringer Guertel 18-20, A-1090 Vienna, Austria
关键词
stress response; intubation; double-lumen-tube; haemodynamics;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Tracheal intubation causes a haemodynamic response that might be harmful for patients. The Airtraq (R) laryngoscope has been shown to decrease the haemodynamic response to single-lumen tube intubation. We hypothesised that double-lumen bronchial tube placement with the Double-lumen Airtraq (R) laryngoscope would cause a reduced haemodynamic response and decreased catecholamine release compared with the MacIntosh laryngoscope. Methods: Forty adult patients were randomly assigned to the Airtraq (R) group or to the MacIntosh group. Intubation with either the Airtraq (R) or the MacIntosh laryngoscope was performed two minutes after standardised induction of anaesthesia. Arterial blood pressure, heart rate, catecholamine levels, bispectral index and duration of the intubation procedure were measured. Results: Mean (standard deviation [95% confidence interval]) systolic arterial blood pressure at laryngoscopy with the Airtraq (R) laryngoscope was 124 (34 [106 to 141]) mmHg and, with the MacIntosh laryngoscope, it was 110 (25 [99 to 122]) mmHg (p = 1.0). Heart rate at laryngoscopy with the Airtraq (R) laryngoscope was 75 beats min-1 (16 [67 to 83]) and, with the MacIntosh laryngoscope, it was 64 beats . min-1 (14 [58 to 71]) (p = 0.71). Adrenaline levels post-intubation were 54.3 ng . l-1 (41.5) [29.3 to 79.4] in the Airtraq r group and 30.5 ng . l-1 (25.6) [15.1 to 46.0] in the MacIntosh group (p = 0.016). The duration of intubation with the Airtraq r laryngoscope was 88 s (31 [72-104]) while, with the MacIntosh laryngoscope, the duration was 75 s (35 [59-92]) (p = 0.26). Conclusions: The use of the Double-lumen Airtraq (R) laryngoscope provides no benefit regarding stress response compared to the MacIntosh laryngoscope.
引用
收藏
页码:54 / 63
页数:10
相关论文
共 28 条
  • [1] Comparison of Airtraq DL™ and Macintosh laryngoscope for double-lumen tube placement in simulated difficult airway: A randomised study
    Mounika, K.
    Kar, Prachi
    Padhy, Shibani
    Pathy, Archana
    Durga, Padmaja
    INDIAN JOURNAL OF ANAESTHESIA, 2022, 66 (06) : 442 - 448
  • [2] Haemodynamic response and effectiveness of tracheal intubation with Airtraq (R) versus Macintosh laryngoscope in paediatric patient undergoing elective surgery: Prospective, randomised and blind clinical trial
    Orozco, J. A.
    Rojas, J. L.
    Medina-Vera, A. J.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2018, 65 (01): : 24 - 30
  • [3] Comparison of the Airtraq laryngoscope and the GlideScope for double-lumen tube intubation in patients with predicted normal airways: a prospective randomized trial
    Jie Yi
    Yahong Gong
    Xiang Quan
    Yuguang Huang
    BMC Anesthesiology, 15
  • [4] Comparison of the Airtraq laryngoscope and the GlideScope for double-lumen tube intubation in patients with predicted normal airways: a prospective randomized trial
    Yi, Jie
    Gong, Yahong
    Quan, Xiang
    Huang, Yuguang
    BMC ANESTHESIOLOGY, 2015, 15
  • [5] McGrath Series 5 videolaryngoscope vs Airtraq DL videolaryngoscope for double-lumen tube intubation A randomized trial
    Wan, Li
    Liao, Mingfeng
    Li, Li
    Qian, Wei
    Hu, Rong
    Chen, Kun
    Zhang, Chuanhan
    Yao, Wenlong
    MEDICINE, 2016, 95 (51) : e5739
  • [6] Combined use of the ProSeal laryngeal mask airway and a bronchial blocker vs. a double-lumen endobronchial tube in thoracoscopic surgery: A randomized controlled trial
    Nakanishi, Toshiyuki
    Sento, Yoshiki
    Kamimura, Yuji
    Nakamura, Ryuji
    Hashimoto, Hiroya
    Okuda, Katsuhiro
    Nakanishi, Ryoichi
    Sobue, Kazuya
    JOURNAL OF CLINICAL ANESTHESIA, 2023, 88
  • [7] Videolaryngoscopy vs. Macintosh laryngoscopy for double-lumen tube intubation in thoracic surgery: a systematic review and meta-analysis
    Liu, T. T.
    Li, L.
    Wan, L.
    Zhang, C. H.
    Yao, W. L.
    ANAESTHESIA, 2018, 73 (08) : 997 - 1007
  • [8] Left double-lumen tube with or without a carinal hook A randomised controlled trial
    Dumans-Nizard, Virginie
    Parquin, Jean-Francois
    Moyer, Jean-Denis
    Dreyfus, Jean Francois
    Fischler, Marc
    Le Guen, Morgan
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2015, 32 (06) : 418 - 424
  • [9] McGrath MAC video laryngoscope versus direct laryngoscopy for the placement of double-lumen tubes: A randomised control trial
    Bakshi, Sumitra G.
    Gawri, Ajay
    Divatia, Jigeeshu, V
    INDIAN JOURNAL OF ANAESTHESIA, 2019, 63 (06) : 456 - 461
  • [10] Hyperangulated vs. Macintosh videolaryngoscopy in adults with anticipated difficult airway management: a randomised controlled trial
    Koehl, Vera
    Wuensch, Viktor A.
    Mueller, Marie-Claire
    Sasu, Phillip B.
    Dohrmann, Thorsten
    Peters, Tanja
    Tolkmitt, Josephine
    Dankert, Andre
    Krause, Linda
    Zoellner, Christian
    Petzoldt, Martin
    ANAESTHESIA, 2024, 79 (09) : 957 - 966