CARDIOPULMONARY-RESUSCITATION WITHOUT INTERMITTENT POSITIVE PRESSURE VENTILATION

被引:8
作者
OKAMOTO, K
KISHI, H
CHOI, H
MORIOKA, T
机构
[1] Division of Intensive and Critical Care Medicine, Kumamoto University School of Medicine, Kumamoto, 860
[2] Department of Anesthesiology, Kumamoto University School of Medicine, Kumamoto, 860
关键词
CARDIOPULMONARY RESUSCITATION; EMERGENCY VENTILATION; INTERMITTENT POSITIVE PRESSURE VENTILATION; TRACHEAL INSUFFLATION OF OXYGEN;
D O I
10.1016/0300-9572(93)90146-H
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The purpose of this study was to examine whether tracheal insufflation of oxygen (TRIO) could be used as a substitute for intermittent positive pressure ventilation (IPPV) during cardiopulmonary resuscitation (CPR) in dogs with orotracheal intubation. Twenty-seven anesthetized, paralyzed and intubated dogs were used. The tip of the insufflation catheter was placed 1 cm distal to the top of the endotracheal tube. The effects of TRIO at a flow rate of 10 1/min with or without a continuous positive airway pressure (CPAP) of 5.cmH(2)O during external cardiac compressions were compared with those managed under the standard CPR. During CPR, TRIO without CPAP maintained adequate gas exchange. Peak airway-pressures in the TRIO groups were significantly lower than that in the standard CPR group. No significant differences were observed in arterial, pulmonary artery and diastolic right atrial pressures during CPR among the three groups: However, the coronary perfusion pressures in the TRIO group with CPAP always tended to be low during CPR. The present study suggests that TRIO without CPAP should be a promising substitute for IPPV during CPR when IPPV is not feasible.
引用
收藏
页码:251 / 260
页数:10
相关论文
共 12 条
[1]  
Guidelines for cardiopulmonary resuscitation and emergency cardiac care, JAMA: The Journal of the American Medical Association, 268, pp. 2171-2302, (1992)
[2]  
Slutsky, Watson, Leith, Brown, Tracheal insufflation of oxygen (TRIO) at low flow rates sustains life for several hours, Anesthesiology, 63, pp. 278-286, (1985)
[3]  
Urata, Okamoto, Morioka, Respiration by tracheal insufflation of oxygen (TRIO) at high flow rates in apneic dogs, J Anesth, 5, pp. 153-159, (1991)
[4]  
Okamoto, Urata, Katsuya, Morioka, Effects of tracheal insufflation of oxygen (TRIO) on blood gases during external cardiac compressions in dogs under ventricular fibrillation, J Anesth, 3, pp. 16-22, (1989)
[5]  
Okamoto, Morioka, Transtracheal 02 insufflation (TOI) as an alternative method of ventilation during cardiopulmonary resuscitation, Resuscitation, 20, pp. 253-262, (1990)
[6]  
Adrogue, Rashad, Gorin, Yacoub, Madias, Assessing acid-base status in circulatory failure. Differences between arterial central venous blood, N Engl J Med, 320, pp. 1312-1316, (1989)
[7]  
Paradis, Martin, Rivers, Goetting, Appleton, Feingold, Nowak, Coronary perfusion pressure and the return of spontaneous circulation in human cardiopulmonary resuscitation, J Am Med Assoc, 263, pp. 1106-1113, (1990)
[8]  
Meltzer, Auer, Continuous respiration without respiratory movements, Journal of Experimental Medicine, 11, pp. 622-625, (1909)
[9]  
Lehnert, Oberdorster, Slutsky, Constant-flow ventilation of apneic dogs, J Appl Physiol, 53, pp. 483-489, (1982)
[10]  
Burwen, Watson, Brown, Josa, Slutsky, Effect of cardiogenic oscillations on gas mixing during tracheal insufflation of oxygen, J Appl Physiol, 60, pp. 965-971, (1986)