Usefulness of the bispectral index during cardiopulmonary resuscitation -A case report-

被引:7
|
作者
Jung, Jin Yong [1 ]
Kim, Yeonbaek [1 ]
Kim, Jung-Eun [1 ]
机构
[1] Catholic Univ Daegu, Sch Med, Dept Anesthesiol & Pain Med, 3056-6,Daemyung 4 Dong, Daegu 705718, South Korea
关键词
Bispectral index; Cardiopulmonary resuscitation; Consciousness;
D O I
10.4097/kjae.2013.64.1.69
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The usefulness of using the bispectral index (BIS) for monitoring during cardiopulmonary resuscitation (CPR) is not clearly understood. However, BIS has been a popular anesthetic monitoring device used during operations. The case presented is of a pregnant woman going into cardiac arrest due to an amniotic fluid embolism during a Cesarean section. CPR was performed, but neither the return of spontaneous circulation (ROSC) nor the return of consciousness was achieved, despite 50 min of effective CPR. However, CPR was continued based on BIS. ROSC was achieved, and an alert consciousness state was reached 1 day postoperation. This finding suggests that BIS be used as a basic monitoring device during CPR and that it may help in deciding to continue CPR.
引用
收藏
页码:69 / 72
页数:4
相关论文
共 50 条
  • [1] Pitfall of bispectral index during intraoperative seizure -a case report-
    Kim, Hyungdong
    Kim, Sae Young
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2013, 65 (05) : 449 - 452
  • [2] Value of bispectral index monitoring during cardiopulmonary resuscitation
    Szekely, B
    Saint-Marc, T
    Degrémont, AC
    Castelain, MH
    Fischler, M
    BRITISH JOURNAL OF ANAESTHESIA, 2002, 88 (03) : 443 - 444
  • [3] Interruption of bispectral index monitoring by nerve integrity monitoring during tympanoplasty -A case report-
    Kim, Jun Hyun
    Kim, Ah Na
    Kim, Kyung Woo
    Lee, Sang-Il
    Kim, Ji Yeon
    Kim, Kyung-Tae
    Park, Jang Su
    Kim, Jung Won
    Choe, Won Joo
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2013, 64 (02) : 161 - 163
  • [4] Bispectral index monitoring during cardiopulmonary resuscitation repeated twice within 8 days in the same patient: a case report
    Michael T. Pawlik
    Timo F. Seyfried
    Christian Riegger
    Werner Klingler
    Christoph Selig
    International Journal of Emergency Medicine, 2008, 1 (3) : 209 - 212
  • [5] Bispectral index monitoring during cardiopulmonary resuscitation repeated twice within 8 days in the same patient: a case report
    Pawlik, Michael T.
    Seyfried, Timo F.
    Riegger, Christian
    Klingler, Werner
    Selig, Christoph
    INTERNATIONAL JOURNAL OF EMERGENCY MEDICINE, 2008, 1 : 209 - 212
  • [6] Bispectral index recorded during prehospital cardiopulmonary resuscitation as a predictor of survival
    Soto Garcia, Maria Angeles
    Giraldo Sebastia, Jose Manuel
    Carmona Jimenez, Francisco Jose
    Jimenez Fabrega, Xavier
    EMERGENCIAS, 2012, 24 (01): : 35 - 38
  • [7] Bispectral index is an indicator of adequate cerebral perfusion during cardiopulmonary resuscitation
    Chakravarthy, M
    Patil, T
    Jayaprakash, K
    Shivananda, N
    Jawali, V
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (04) : 506 - 508
  • [8] Prognostic evaluation of bispectral index in patients following cardiopulmonary resuscitation
    Liu, Han
    Liu, Ying
    Xu, Ying
    Xue, Yan
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 5 (03) : 907 - 911
  • [9] Bispectral index analysis during cardiac arrest and cardiopulmonary resuscitation in a propofol-anesthetized calf
    Aprea, Francesco
    Martin-Jurado, Olga
    Jenni, Simon
    Mosing, Martina
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2014, 24 (02) : 221 - 225
  • [10] Usefulness of bispectral index during laparoscopic surgery
    Mavoungou, P
    Billard, V
    Moussaud, R
    ANESTHESIOLOGY, 1998, 89 (3A) : U815 - U815