TRANSMITTING PROPERTIES OF POROUS PB(ZR, TI)O3 TRANSDUCER

被引:6
作者
KURIHARA, Y
MIZUMURA, K
OHASHI, H
机构
[1] Japan Radio Co Ltd., Kamifukuokashi
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS | 1992年 / 31卷 / 9B期
关键词
POROUS PZT; TRANSMITTING PROPERTY; ECHO SOUNDER; DISPLACEMENT CHARACTERISTICS; LASER INTERFEROMETER;
D O I
10.1143/JJAP.31.3067
中图分类号
O59 [应用物理学];
学科分类号
摘要
The displacement characteristics of the applied voltage on porous-Pb(Zr, Ti)O3 (P-PZT) are measured by the laser interferometry system. The static displacement characteristics are measured by applying DC voltage to avoid the interference from the various vibration modes. Also, the dynamic displacement characteristics are measured by applying AC voltage of the resonance frequency at 200 kHz. These displacement characteristics showed a dependence on the porosity of P-PZT, and the displacements increased as the porosity of P-PZT increased. P-PZT is applied to the echo sounder to evaluate the transmitting properties in water, and the improved transmitting sensitivity of 3.5 dB in reference to the conventional (nonporous) PZT, is obtained when the porosity of P-PZT is increased to 27%.