Comparison of endothelial/Descemet's membrane complex thickness with endothelial cell density for the diagnosis of corneal transplant rejection

被引:5
作者
Smith, Christopher [2 ]
Kaitis, Daniel [2 ]
Winegar, Jordan [2 ]
Edelstein, Sean [2 ]
Council, Matthew [2 ]
Kontadakis, George [3 ]
Bentivegna, Rocio [2 ]
Abou Shousha, Mohamed [1 ,2 ]
机构
[1] Bascom Palmer Eye Inst, Dept Ophthalmol, 900 NW 17th St, Miami, FL 33136 USA
[2] St Louis Univ, Eye Inst, St Louis, MO 63103 USA
[3] Univ Crete, Inst Vis & Opt, Iraklion, Greece
关键词
corneal graft rejection; Descemet's membrane; endothelial cell density; optical coherence tomography;
D O I
10.1177/2515841418814187
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: This study compared the effectiveness of endothelial/Descemet's membrane complex thickness obtained using high-definition anterior segment optical coherence tomography with endothelial cell density obtained using confocal microscopy as diagnostic tools in predicting corneal transplant rejection. Methods: This observational, prospective, cross-sectional study evaluated penetrating keratoplasty grafts. Slit lamp examination organized the grafts into healthy or rejecting grafts. Grafts were scanned using both high-definition anterior segment optical coherence tomography and confocal microscopy. Central corneal thickness, endothelial/Descemet's membrane complex thickness, endothelial cell density, and coefficient of variation were each compared with the clinical status. Descemet's rejection index, defined by endothelial/Descemet's membrane complex thickness divided by central corneal thickness multiplied by 33, further compared endothelial/Descemet's membrane complex thickness with central corneal thickness. Results: Endothelial/Descemet's membrane complex thickness, central corneal thickness, and Descemet's rejection index were all able to differentiate between clear and rejected corneal grafts (p < 0.0001, p = 0.001, and p = 0.012, respectively). Endothelial cell density and coefficient of variation did not correlate with the clinical status (p = 0.054 and p = 0.102, respectively). Endothelial/Descemet's membrane complex thickness had the largest area under the curve using receiver operating characteristic curves (p < 0.0001). Endothelial/Descemet's membrane complex thickness had a sensitivity of 86% and specificity of 81% with a cutoff value of >16.0 mu m (p < 0.0001). The sensitivity and specificity of endothelial cell density were both 71% with a cutoff value of <= 897 cells/mm(2) (p = 0.053). There was a high correlation between endothelial/Descemet's membrane complex thickness and both Descemet's rejection index and central corneal thickness (p < 0.0001). Conclusion: Endothelial/Descemet's membrane complex thickness measured by high-definition anterior segment optical coherence tomography is a useful parameter for the diagnosis of corneal graft rejection. The diagnostic performance of endothelial/Descemet's membrane complex thickness was significantly better than that of endothelial cell density and central corneal thickness. Endothelial cell density and the coefficient of variation were unable to diagnose corneal graft rejection in our cross-sectional study.
引用
收藏
页数:9
相关论文
共 25 条
[1]   In Vivo Characteristics of Corneal Endothelium/Descemet Membrane Complex for the Diagnosis of Corneal Graft Rejection [J].
Abou Shousha, Mohamed ;
Yoo, Sonia H. ;
Sayed, Mohamed S. ;
Edelstein, Sean ;
Council, Matthew ;
Shah, Ravi S. ;
Abernathy, Joshua ;
Schmitz, Zachary ;
Stuart, Patrick ;
Bentivegna, Rocio ;
Fernandez, Maria P. ;
Smith, Christopher ;
Yin, Xiaotang ;
Harocopos, George J. ;
Dubovy, Sander R. ;
Feuer, William J. ;
Wang, Jianhua ;
Perez, Victor L. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 178 :27-37
[2]   Use of Ultra-High-Resolution Optical Coherence Tomography to Detect In Vivo Characteristics of Descemet's Membrane in Fuchs' Dystrophy [J].
Abou Shousha, Mohamed ;
Perez, Victor L. ;
Wang, Jianhua ;
Ide, Takeshi ;
Jiao, Shuliang ;
Chen, Qi ;
Chang, Victoria ;
Buchser, Nancy ;
Dubovy, Sander R. ;
Feuer, William ;
Yoo, Sonia H. .
OPHTHALMOLOGY, 2010, 117 (06) :1220-1227
[3]   Thickening of the peritubular capillary basement membrane is a useful diagnostic marker of chronic rejection in renal allografts [J].
Aita, K. ;
Yamaguchi, Y. ;
Horita, S. ;
Ohno, M. ;
Tanabe, K. ;
Fuchinoue, S. ;
Teraoka, S. ;
Toma, H. ;
Nagata, M. .
AMERICAN JOURNAL OF TRANSPLANTATION, 2007, 7 (04) :923-929
[4]  
Basak Samar K., 2004, Indian Journal of Ophthalmology, V52, P151
[5]   Corneal Endothelium-Past, Present, and Future [J].
Bourne, William M. .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2010, 36 (05) :310-314
[6]  
Bourne WM, 1997, INVEST OPHTH VIS SCI, V38, P779
[7]   Corneal Graft Rejection 10 Years After Penetrating Keratoplasty in the Cornea Donor Study [J].
Dunn, Steven P. ;
Gal, Robin L. ;
Kollman, Craig ;
Raghinaru, Dan ;
Dontchev, Mariya ;
Blanton, Christopher L. ;
Holland, Edward J. ;
Lass, Jonathan H. ;
Kenyon, Kenneth R. ;
Mannis, Mark J. ;
Mian, Shahzad I. ;
Rapuano, Christopher J. ;
Stark, Walter J. ;
Beck, Roy W. .
CORNEA, 2014, 33 (10) :1003-1009
[8]   Ten-year postoperative results of penetrating keratoplasty [J].
Ing, JJ ;
Ing, HH ;
Nelson, LR ;
Hodge, DO ;
Bourne, WM .
OPHTHALMOLOGY, 1998, 105 (10) :1855-1865
[9]  
Jakobiec FA, 2010, AM J OPHTHALMOL, V150
[10]   Longterm follow-up of penetrating keratoplasty for keratoconus [J].
Jensen, Lene Bang ;
Hjortdal, Jesper ;
Ehlers, Niels .
ACTA OPHTHALMOLOGICA, 2010, 88 (03) :347-351