COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF BO-2727, A NEW CARBAPENEM ANTIBIOTIC, IN HUMAN PLASMA AND URINE BY DIRECT-INJECTION

被引:10
|
作者
TAKANO, T [1 ]
KAGAMI, Y [1 ]
KUWABARA, Y [1 ]
HATA, S [1 ]
机构
[1] BANYU PHARMACEUT CO,DEV RES LABS,DRUG METAB,SAITAMA 36002,JAPAN
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1994年 / 656卷 / 02期
关键词
D O I
10.1016/0378-4347(94)00128-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A column-switching high-performance liquid chromatographic method has been developed for the simple and sensitive analysis of BO-2727 (I) in human plasma and urine. Plasma samples were diluted with an equal volume of a stabilizer, and the mixture was directly injected onto the HPLC system. The analyte was enriched in a pre-treatment column, while endogenous components were eluted to waste. The analyte was then backflushed onto an analytical column and quantified with ultraviolet detection. Urinary concentrations were determined in a similar way except that the enriched analyte was eluted in the foreflush mode to a cation-exchange column used for chromatographic separation. The standard curves for the drug were linear in the range of 0.05-50 mu g/ml in plasma and 0.5-100 mu g/ml in urine. The limits of quantification for plasma and urine were found to be 0.05 mu g/ml and 0.5 mu g/ml, respectively. This method was used to support Phase I clinical pharmacokinetic studies.
引用
收藏
页码:353 / 358
页数:6
相关论文
共 50 条