COMPARISON BETWEEN THE XE-133 CLEARANCE METHOD AND THE MICROSPHERE TECHNIQUE IN CEREBRAL BLOOD-FLOW DETERMINATIONS IN THE DOG

被引:30
作者
FAN, FC
CHEN, RYZ
SCHUESSLER, GB
CHIEN, S
机构
[1] COLUMBIA UNIV COLL PHYS & SURG,DEPT PHYSIOL,NEW YORK,NY 10032
[2] COLUMBIA UNIV COLL PHYS & SURG,DEPT ANAESTHESIOL,NEW YORK,NY 10032
关键词
D O I
10.1161/01.RES.44.5.653
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We compared the 133Xe clearance method and the microsphere technique (15-μm spheres) for cerebral blood flow determination in 15 mongrel dogs. The 133Xe clearance curve obtained from sampling dorsal sagittal sinus blood following left ventricular injection showed either two or three components. Blood flow calculated from the first component can be correlated with the average gray matter blood flow through the caudate nucleus, the cortical gray, and the thalamus calculated from the microsphere data. The second component of the 133Xe curve correlated well with the white matter blood flow measured with microspheres. In seven out of 15 experiments, there was a third component in the 133Xe clearance curve. The blood flow obtained from the third component showed a close correlation with extracranial muscle blood flow determined with microspheres. The mean cerebral blood flow measured with the 133Xe clearance method was in close agreement with that obtained by the microsphere technique. After the injection of 133Xe into extracranial muscles, the slope of the clearance curve obtained from the dorsal sagittal sinus correlated well with that of the third component following left ventricular injection. The results indicate that regional cerebral blood flows measured with 15-μm microsphere can be correlated with those obtained from various components of the simultaneous 133Xe clearance. These findings also point out the necessity of considering the contribution of extracranial muscles when analyzing the 133Xe clearance curve.
引用
收藏
页码:653 / 659
页数:7
相关论文
共 50 条
  • [41] STOCHASTIC ANALYSIS OF XE-133 CLEARANCE FOR DETERMINING REGIONAL CEREBRAL BLOOD-FLOW IN A PRIMATE MODEL
    AGRESS, H
    BACHARACH, SL
    HAMMOCK, MK
    GREEN, MV
    JOHNSTON, GS
    DICHIRO, G
    STROKE, 1977, 8 (02) : 222 - 226
  • [42] DIFFERENTIAL-EFFECTS OF MOOD ON CORTICAL CEREBRAL BLOOD-FLOW - A XE-133 CLEARANCE STUDY
    SCHNEIDER, F
    GUR, RC
    JAGGI, JL
    GUR, RE
    PSYCHIATRY RESEARCH, 1994, 52 (02) : 215 - 236
  • [43] EXPERIMENTAL-STUDY OF A XE-133 CLEARANCE METHOD FOR MEASUREMENT OF LIVER BLOOD-FLOW
    MATHIE, RT
    HUGHES, RL
    HARPER, AM
    BLUMGART, LH
    GUT, 1978, 19 (05) : A454 - A454
  • [44] XE-133 MUSCLE CLEARANCE IN DISTURBANCES OF PERIPHERIAL ARTERIAL BLOOD-FLOW
    KIRSCH, G
    HOWNER, B
    RADIOBIOLOGIA-RADIOTHERAPIA, 1977, 18 (02) : 215 - 224
  • [45] BLOOD-FLOW IN PROXIMAL FEMUR OF THE DOG DETERMINED BY THE LOCAL XE-133 INJECTION METHOD
    LAHTINEN, T
    ALHAVA, EM
    HAKUMAKI, M
    JAASKELAINEN, J
    VAANANEN, A
    KARJALAINEN, P
    ACTA PHYSIOLOGICA SCANDINAVICA, 1979, 106 (04): : 437 - 440
  • [46] LIVER BLOOD-FLOW MEASUREMENT INTERPRETATION OF XE-133 CLEARANCE CURVES
    MACKENZIE, RJ
    LEIBERMAN, DP
    MATHIE, RT
    RICE, GC
    HARPER, AM
    BLUMGART, LH
    ACTA CHIRURGICA SCANDINAVICA, 1976, 142 (07): : 519 - 525
  • [47] COMPARISON OF QUANTITATIVE AUTORADIOGRAPHIC AND XE-133 CLEARANCE METHODS - CORRELATION OF GRAY AND WHITE MATTER CEREBRAL BLOOD-FLOW WITH COMPARTMENTAL BLOOD-FLOW INDEXES
    TUOR, UI
    FITCH, W
    GRAHAM, DI
    MENDELOW, AD
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1986, 6 (04) : 481 - 485
  • [48] CONTRALATERAL TESTICULAR BLOOD-FLOW IN UNILATERAL TESTICULAR TORSION MEASURED BY THE XE-133 CLEARANCE TECHNIQUE
    MELIKOGLU, M
    GUNTEKIN, E
    ERKILIC, M
    KARAVELI, S
    BRITISH JOURNAL OF UROLOGY, 1992, 69 (06): : 633 - 635
  • [49] MEASUREMENT OF TONSILLAR BLOOD-FLOW IN NORMAL AND PATHOLOGICAL CONDITIONS BY THE USE OF THE XE-133 CLEARANCE TECHNIQUE
    OZDEMIR, I
    ERCAN, MT
    KAYA, S
    ARCHIVES OF OTO-RHINO-LARYNGOLOGY-ARCHIV FUR OHREN-NASEN-UND KEHLKOPFHEILKUNDE, 1985, 242 (01): : 53 - 56
  • [50] MEASUREMENT OF TENDON BLOOD-FLOW IN RABBITS BY MICROSPHERE UPTAKE AND XE-133 WASHOUT
    TOTHILL, P
    HOOPER, G
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1985, 10B (01) : 17 - 20