MEASUREMENT OF COLONIC TRANSIT-TIME USING RADIONUCLIDE IMAGING - ANALYSIS BY CONDENSED IMAGES

被引:19
作者
NOTGHI, A
KUMAR, D
PANAGAMUWA, B
TULLEY, NJ
HESSLEWOOD, SR
HARDING, LK
机构
[1] Physics and Nuclear Medicine, Dudley Road Hospital, Birmingham
[2] Department of Surgery, Queen Elizabeth Hospital, Birmingham
关键词
D O I
10.1097/00006231-199303000-00010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A polymer-coated capsule has been used in eight volunteer subjects to deliver In-111-resin into the ileocaecal region. The images were acquired for up to 3 days to follow transit through the colon. Expressing the results of individual studies is difficult and time-activity curves for each region are confusing. Calculation of the geometric centre indicates only where the middle of the activity has reached. We describe a new method of presenting colonic transit data as parametric images. The parametric images show the amount of activity in each area of interest as the study progresses. This is readily understood and allows segmental movement of the isotope, either forward or retrograde, to be examined. The geometric mean of activity in four areas of the colon were also calculated. Four hours after reaching the ileocaecal region, 65% (S.D. 24%) of the activity was in the caecum and 26% (S.D. 20%) in the transverse colon. By 24 h three controls had excreted most of the activity, in two the activity was mainly in the rectum and in two there was still some activity in the transverse colon. A protocol for colonic transit studies, problems with analysis and a new method of presentation of data are discussed.
引用
收藏
页码:204 / 211
页数:8
相关论文
共 50 条
  • [41] Transit-time analysis in hepatic cirrhosis
    Bendtsen, F
    Henriksen, JH
    LANCET, 1999, 354 (9178) : 598 - 599
  • [42] MEASUREMENT OF GASTRIC-EMPTYING, INTESTINAL TRANSIT-TIME, AND COLONIC FILLING BY SCINTISCAN IN HEALTHY-SUBJECTS
    LARTIGUE, S
    BIZAIS, Y
    DESVARANNES, B
    CLOAREC, D
    GALMICHE, JP
    GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 1991, 15 (05): : 379 - 385
  • [43] MEASUREMENT OF OROCECAL TRANSIT-TIME BY A NEW FERROMAGNETIC TECHNIQUE
    OLIVEIRA, RB
    MIRANDA, JR
    BAFFA, O
    MATSUDA, NM
    TRONCON, LEA
    GUT, 1991, 32 (10) : A1215 - A1215
  • [44] COLONIC TRANSIT-TIME AND ANORECTAL MANOMETRY IN CHRONIC IDIOPATHIC CONSTIPATION (CIC)
    WALD, A
    GASTROENTEROLOGY, 1985, 88 (05) : 1626 - 1626
  • [45] IMPROVED INTERVAL TRANSIT-TIME MEASUREMENT BASED ON SEMBLANCE
    KIMBALL, CV
    MARZETTA, TL
    GEOPHYSICS, 1984, 49 (05) : 633 - 634
  • [46] ULTRASONIC TRANSIT-TIME SYSTEM FOR ARTERIAL DIAMETER MEASUREMENT
    BERTRAM, CD
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1977, 15 (05) : 489 - 499
  • [47] EFFECT OF CHANGING TRANSIT-TIME ON COLONIC MICROBIAL-METABOLISM IN MAN
    STEPHEN, AM
    WIGGINS, HS
    CUMMINGS, JH
    GUT, 1987, 28 (05) : 601 - 609
  • [48] Inter-observer reproducibility of quantitative radionuclide colonic transit imaging
    Masoomi, MA
    Britten, AJ
    Kumar, D
    Joseph, AEA
    NUCLEAR MEDICINE COMMUNICATIONS, 1999, 20 (06) : 547 - 550
  • [49] TESTING MINIMAL TRANSIT-TIME IN THE VENOUS SYSTEM OF THE LOWER-LIMBS USING DYNAMIC RADIONUCLIDE VENOGRAPHY
    MARK, B
    SZABO, M
    NEMESSANYI, Z
    MENYHEI, G
    ENDREDI, J
    INTERNATIONAL ANGIOLOGY, 1988, 7 (03) : 231 - 233
  • [50] MEAN TRANSIT-TIME PARAMETRIC IMAGES IN BRAIN-TUMORS
    VOSBERG, H
    SZABO, Z
    NASE, D
    FEINENDEGEN, LE
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1983, 8 (05): : A33 - A33