BIOCOMPATIBILITY OF HYDROXYAPATITE-COATED HIP PROSTHESES

被引:17
|
作者
SANTAVIRTA, S
NORDSTROM, D
YLINEN, P
KONTTINEN, YT
SILVENNOINEN, T
ROKKANEN, P
机构
[1] HELSINKI UNIV HOSP,DEPT MED 4,SF-00170 HELSINKI,FINLAND
[2] HELSINKI UNIV HOSP,DEPT ORTHOPAED & TRAUMATOL,SF-00260 HELSINKI,FINLAND
[3] AURORA HOSP,SF-00250 HELSINKI,FINLAND
[4] HOSP JOINT DIS & MED CTR,INST MOLEC BIOL,INST ORTHOPAED,NEW YORK,NY 10003
关键词
D O I
10.1007/BF00443460
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In three patients a mechanically well-fixed Mathys Ceros 80 (Ha) hydroxyapatite-coated acetabular component was revised 2, 5 and 13 months after total hip replacement due to component malposition. In each case there was a thin cellular connective tissue membrane between hydroxyapatite and bone, the main cell type being fibroblast with only occasional giant cells. Immunohistological analysis revealed some MHC locus II antigen positive cells that were identified as monocytes. No interleukin-2 receptor positive cells were found. Under clinical cyclic loading conditions there does not seem to be chemical fixation or bony ingrowth into the hydroxyapatite coated prosthesis component. In human lymphocyte cultures, hydroxyapatite (Interpore 200, particle diameters 15-40-mu-m) did not cause an increase in lymphocyte DNA synthesis as assessed by the H-3-thymidine incorporation method on culture days 1, 3 and 5. As analysed with lymphocyte activation markers, the hydroxyapatite-dependent expression of MHC locus II antigen was modest and differed significantly (P < 0.05) from that in culture medium only on day 3. Hydroxyapatite induced only a slight interleukin-2 receptor expression that did not differ from culture medium on days 1, 3 and 5. CD4 and CD8 positive lymphocytes as well as monocytes were not seen attached to hydroxyapatite particles during the culture days. Our findings suggest that hydroxyapatite is an immunologically inert implant material.
引用
收藏
页码:288 / 292
页数:5
相关论文
共 50 条
  • [22] High survival rate of hydroxyapatite-coated hip prostheses - 100 consecutive hips followed for 10 years
    Oosterbos, CJM
    Rahmy, AIA
    Tonino, AJ
    Witpeerd, W
    ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (02): : 127 - 133
  • [23] Hydroxyapatite-coated RM cup in primary hip arthroplasty
    Salman M. Ali
    A. Kumar
    International Orthopaedics, 2003, 27 : 90 - 93
  • [24] RETRIEVAL ANALYSIS OF A HYDROXYAPATITE-COATED HIP-PROSTHESIS
    BLOEBAUM, RD
    MERRELL, M
    GUSTKE, K
    SIMMONS, M
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1991, (267) : 97 - 102
  • [25] Hydroxyapatite-coated RM cup in primary hip arthroplasty
    Ali, MS
    Kumar, A
    INTERNATIONAL ORTHOPAEDICS, 2003, 27 (02) : 90 - 93
  • [26] Furlong Hydroxyapatite-Coated Hip Prosthesis vs the Charnley Cemented Hip Prosthesis
    Chandran, Prakash
    Azzabi, Mohamed
    Miles, Jeremy
    Andrews, Mark
    Bradley, John
    JOURNAL OF ARTHROPLASTY, 2010, 25 (01): : 52 - 57
  • [27] 2-YEAR OUTCOME OF HYDROXYAPATITE-COATED PROSTHESES - 2 FEMORAL PROSTHESES RETRIEVED AT AUTOPSY
    HARDY, DCR
    FRAYSSINET, P
    BONEL, G
    AUTHOM, T
    LENAELOU, SA
    DELINCE, PE
    ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (03): : 253 - 257
  • [28] Hydroxyapatite-coated bipolar hemiarthroplasty for displaced intracapsular hip fracture
    Bradley, J
    Andrews, C
    Matteucci, P
    Burton, D
    Khalil, A
    Azzabi, M
    Cordosa, P
    OSTEOPOROSIS INTERNATIONAL, 2002, 13 : S19 - S19
  • [29] Bone scintigraphic appearance of asymptomatic hydroxyapatite-coated hip arthroplasties
    Moilanen, T
    Scott, G
    Newell, M
    Garvie, N
    Freeman, MAR
    JOURNAL OF ARTHROPLASTY, 1997, 12 (04): : 380 - 386
  • [30] EXPERIMENTAL AND CLINICAL-EXPERIENCE WITH HYDROXYAPATITE-COATED HIP IMPLANTS
    GEESINK, RGT
    ORTHOPEDICS, 1989, 12 (09) : 1239 - 1242