Advanced bronchoscopy for the diagnosis of peripheral pulmonary lesions

被引:30
作者
Asano, Fumihir [1 ]
机构
[1] Gifu Prefectural Gen Med Ctr, Dept Pulm Med, 4-6-1 Noishiki, Gifu 5008717, Japan
关键词
Electromagnetic navigation; Endobronchial ultrasound; Lung cancer; Ultrathin bronchoscope; Virtual bronchoscopic navigation;
D O I
10.1016/j.resinv.2015.11.008
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Bronchoscopy to examine peripheral pulmonary lesions is performed using a bronchoscope with an outer diameter of 5-6 mm under fluoroscopy, but the diagnostic yield can be insufficient. Problems with transbronchial biopsy include a limited range of bronchoscope insertion, difficulty in guiding a bronchoscope and biopsy instruments to lesions, and insufficient confirmation of the arrival of biopsy instruments at the target lesion; as such, new techniques have been used to overcome these individual problems. Radial-endobronchial ultrasound is used to identify peripheral pulmonary lesions and sampling sites. In a meta-analysis, the diagnostic yield, that of lesions smaller than 2 cm, and complication rate were 73, 56.3, and 1.0%, respectively. Virtual bronchoscopic navigation is a method to guide a bronchoscope to peripheral lesions under direct vision using virtual bronchoscopic images of the bronchial route, and the diagnostic yield, that of 2-cm or smaller lesions, and complication rate were 73.8, 67.4, and 1.0%, respectively. Electromagnetic navigation utilizes electromagnetism; the diagnostic yield was 64.9-71%, and the pneumothorax complication rate was 4% for this modality. Ultrathin bronchoscopes can be advanced to the peripheral bronchus under direct vision in contrast to normal-size bronchoscopes, and the diagnostic yield and pneumothorax complication rates were reported to be 63 and 1.5%, respectively. The overall diagnostic yield of these new techniques on meta-analysis was 70%, a higher yield than that obtained with conventional transbronchial biopsy. Each technique has advantages and disadvantages, and the investigation of appropriate combinations corresponding to individual cases is necessary. (C) 2015 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:224 / 229
页数:6
相关论文
共 32 条
[1]   Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening [J].
Aberle, Denise R. ;
Adams, Amanda M. ;
Berg, Christine D. ;
Black, William C. ;
Clapp, Jonathan D. ;
Fagerstrom, Richard M. ;
Gareen, Ilana F. ;
Gatsonis, Constantine ;
Marcus, Pamela M. ;
Sicks, JoRean D. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (05) :395-409
[2]   Transbronchial biopsy using endobronchial ultrasonography with a guide sheath and virtual bronchoscopic navigation [J].
Asahina, H ;
Yamazaki, K ;
Onodera, Y ;
Kikuchi, E ;
Shinagawa, N ;
Asano, F ;
Nishimura, M .
CHEST, 2005, 128 (03) :1761-1765
[3]  
ASANO F, 2002, J BRONCHOL, V9, P108
[4]   Diagnosis of peripheral pulmonary lesions using a bronchoscope insertion guidance system combined with endobronchial ultrasonography with a guide sheath [J].
Asano, Fumihiro ;
Matsuno, Yoshihiko ;
Tsuzuku, Akifumi ;
Anzai, Masaki ;
Shinagawa, Naofumi ;
Yamazaki, Koichi ;
Ishida, Takashi ;
Moriya, Hiroshi .
LUNG CANCER, 2008, 60 (03) :366-373
[5]   A virtual bronchoscopic navigation system for pulmonary peripheral lesions [J].
Asano, Fumihiro ;
Matsuno, Yoshihiko ;
Shinagawa, Naofumi ;
Yamazaki, Koichi ;
Suzuki, Toshitaka ;
Ishida, Takashi ;
Moriya, Hiroshi .
CHEST, 2006, 130 (02) :559-566
[6]   Virtual Bronchoscopic Navigation for Peripheral Pulmonary Lesions [J].
Asano, Fumihiro ;
Eberhardt, Ralf ;
Herth, Felix J. F. .
RESPIRATION, 2014, 88 (05) :430-440
[7]   Virtual Bronchoscopic Navigation Combined with Ultrathin Bronchoscopy A Randomized Clinical Trial [J].
Asano, Fumihiro ;
Shinagawa, Naofumi ;
Ishida, Takashi ;
Shindoh, Joe ;
Anzai, Masaki ;
Tsuzuku, Akifumi ;
Oizumi, Satoshi ;
Morita, Satoshi .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 188 (03) :327-333
[8]   Bronchoscopic practice in Japan: A survey by the Japan Society for Respiratory Endoscopy in 2010 [J].
Asano, Fumihiro ;
Aoe, Motoi ;
Ohsaki, Yoshinobu ;
Okada, Yoshinori ;
Sasada, Shinji ;
Sato, Shigeki ;
Suzuki, Eiichi ;
Senba, Hiroshi ;
Fujino, Shozo ;
Ohmori, Kazumitsu .
RESPIROLOGY, 2013, 18 (02) :284-290
[9]   Deaths and complications associated with respiratory endoscopy: A survey by the Japan Society for Respiratory Endoscopy in 2010 [J].
Asano, Fumihiro ;
Aoe, Motoi ;
Ohsaki, Yoshinobu ;
Okada, Yoshinori ;
Sasada, Shinji ;
Sato, Shigeki ;
Suzuki, Eiichi ;
Senba, Hiroshi ;
Fujino, Shozo ;
Ohmori, Kazumitsu .
RESPIROLOGY, 2012, 17 (03) :478-485
[10]   Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules [J].
Baaklini, WA ;
Reinoso, MA ;
Gorin, AB ;
Sharafkanch, A ;
Manian, P .
CHEST, 2000, 117 (04) :1049-1054