THE SLOTTED CROSSOVER SURFACE COIL - A DETECTOR FOR INVIVO NMR OF SKIN

被引:17
作者
NAGEL, TL
ALDERMAN, DW
SCHOENBORN, RR
HENDRICKSON, M
SHELBY, J
SAFFLE, J
SCHWEIZER, MP
机构
[1] UNIV UTAH, DEPT SURG, SALT LAKE CITY, UT 84132 USA
[2] UNIV UTAH, DEPT CHEM, SALT LAKE CITY, UT 84132 USA
[3] UNIV UTAH, DEPT RADIOL, SALT LAKE CITY, UT 84132 USA
[4] UNIV UTAH, DEPT MED CHEM, SALT LAKE CITY, UT 84132 USA
关键词
D O I
10.1002/mrm.1910160207
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An elongated, narrow, slotted crossover surface coil provides surface localization capable of resolving in vivo 31 P NMR spectra from skin tissues. The shallow B1 field penetration achieves localization objectives while the probe length maintains signal‐to‐noise requirements. Dielectric and inductive losses are minimized via the crossover design (see T. L. Nagel et al., Magn. Reson. Med. 13, xxx (1990). In vivo spectra with millimeter depth resolution were acquired in 5 min at 2 T without pulse localization sequences. Preliminary 31P NMR spectra of normal and thermally injured rat skin were completed using a 25 × 3‐mm slotted probe with a 3 × 2‐cm surface region of excitation. Normal rat skin tissue PCr/Pi ratios ranged from 3.8 to 4.7 for 5‐, 10‐, and 30‐γs pulse widths, while partial‐and full‐thickness scald injured tissues ranged from 0 to 2.8. Evaluation of a single minor partial thickness injury 1 to 5 h postburn shows evidence of a localized hypermetabolic response associated with hyperemia. Determination of bum depth and tissue viability appears feasible using: (1) PCr/Pi ratios and (2) observation of localized hypermetabolism. © 1990 Academic Press, Inc. Copyright © 1990 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:252 / 268
页数:17
相关论文
共 33 条
[1]   MAPPING OF METABOLITES IN WHOLE ANIMALS BY P-31 NMR USING SURFACE COILS [J].
ACKERMAN, JJH ;
GROVE, TH ;
WONG, GG ;
GADIAN, DG ;
RADDA, GK .
NATURE, 1980, 283 (5743) :167-170
[2]   LASER DOPPLER FLOWMETRY MEASUREMENTS OF SUPERFICIAL DERMAL, DEEP DERMAL AND SUBDERMAL BURNS [J].
ALSBJORN, B ;
MICHEELS, J ;
SORENSEN, B .
SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1984, 18 (01) :75-79
[3]  
BENDALL MR, 1983, J MAGN RESON, V53, P365, DOI 10.1016/0022-2364(83)90211-1
[4]  
CLOWES GHA, 1988, TRAUMA SEPSIS SHOCK, P1
[6]  
COTRAN RS, 1984, PATHOLOGIC BASIS DIS
[7]  
CUONO CB, 1988, PLAST RECONSTR SURG, V81, P1
[8]   RADIOFREQUENCY LOSSES IN NMR EXPERIMENTS ON ELECTRICALLY CONDUCTING SAMPLES [J].
GADIAN, DG ;
ROBINSON, FNH .
JOURNAL OF MAGNETIC RESONANCE, 1979, 34 (02) :449-455
[9]  
GADIAN DG, 1982, NUCLEAR MAGNETIC RES
[10]  
GLASSER O, 1955, MED PHYS, V1, P1493