ELECTROSPRAY-IONIZATION ION MOBILITY SPECTROMETRY

被引:190
|
作者
WITTMER, D
LUCKENBILL, BK
HILL, HH
CHEN, YH
机构
[1] WASHINGTON STATE UNIV,DEPT CHEM,PULLMAN,WA 99164
[2] MILLIPORE CORP,DIV WATERS CHROMATOG,MILFORD,MA 01757
关键词
D O I
10.1021/ac00086a021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An improved electrospray ionization source for ion mobility spectrometry was developed by making three salient modifications to the electrospray needle, First, the needle was removed from the ion drift region, reducing neutralization of charged drops and ions on the walls of the ion mobility drift tube. Second, the tip of the spray needle was electrically insulated, extending the voltage range with which a stable electrospray could be achieved. Third, the needle was cooled, eliminating problems associated with solvent volatilization in the spray needle. Ion mobility spectra of cytochrome c and Triton X-100 were compared with those obtained by electrospray ionization mass spectrometry. While direct mass/charge comparison with ion mobility was not possible, similar electrospray ion patterns between the IMS and MS data suggest that the electrospray ionization source for IMS behaved in a manner consistent with that of other electrospray ionization sources. In addition, mass assignments of IMS ion peaks, made by matching patterns from mass spectra, fit well with those expected from IMS theory.
引用
收藏
页码:2348 / 2355
页数:8
相关论文
共 50 条
  • [1] Mechanical ion gate for electrospray-ionization ion-mobility spectrometry
    Li Zhou
    David C. Collins
    Edgar D. Lee
    Milton L. Lee
    Analytical and Bioanalytical Chemistry, 2007, 388 : 189 - 194
  • [2] Mechanical ion gate for electrospray-ionization ion-mobility spectrometry
    Zhou, Li
    Collins, David C.
    Lee, Edgar D.
    Lee, Milton L.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (01) : 189 - 194
  • [3] Erratum to: Mechanical ion gate for electrospray-ionization ion-mobility spectrometry
    Li Zhou
    David C. Collins
    Edgar D. Lee
    Alan L. Rockwood
    Milton L. Lee
    Analytical and Bioanalytical Chemistry, 2010, 398 : 1833 - 1833
  • [4] Mechanical ion gate for electrospray-ionization ion-mobility spectrometry (vol 388, pg 189, 2007)
    Zhou, Li
    Collins, David C.
    Lee, Edgar D.
    Rockwood, Alan L.
    Lee, Milton L.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (04) : 1833 - 1833
  • [5] Electrospray Ionization Ion Mobility Mass Spectrometry
    Kohoutek, Katie M.
    Harrington, Peter de B.
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2023, 53 (03) : 483 - 497
  • [6] ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    EDMONDS, CG
    SMITH, RD
    METHODS IN ENZYMOLOGY, 1990, 193 : 412 - 431
  • [7] Subambient pressure electrospray ionization ion mobility spectrometry
    Zühlke M.
    Zenichowski K.
    Riebe D.
    Beitz T.
    Löhmannsröben H.-G.
    Zühlke, M. (mzuehlke@uni-potsdam.de), 1600, Springer Verlag (20): : 47 - 56
  • [8] Design for electrospray ionization-ion mobility spectrometry
    Khayamian, T.
    Jafari, M. T.
    ANALYTICAL CHEMISTRY, 2007, 79 (08) : 3199 - 3205
  • [9] High resolution electrospray ionization ion mobility spectrometry
    Krueger, Clinton A.
    Hilton, Christopher K.
    Osgood, Mark
    Wu, Jianglin
    Wu, Ching
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2009, 12 (01) : 33 - 37
  • [10] Thermal effects on electrospray ionization ion mobility spectrometry
    Chen, YH
    Hill, HH
    Wittmer, DP
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1996, 154 (1-2): : 1 - 13