LONG-TIP GUIDING CATHETER - SUCCESSFUL AND SAFE FOR LEFT CORONARY-ARTERY ANGIOPLASTY

被引:6
作者
VODA, J
机构
[1] Baptist Medical Plaza, Oklahoma City
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1992年 / 27卷 / 03期
关键词
GUIDING CATHETER; CORONARY ANGIOPLASTY; LEFT CORONARY ARTERY;
D O I
10.1002/ccd.1810270317
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A long-tip guiding catheter was designed for angioplasty of the left coronary artery. Principal factors of guiding catheter function were identified, and the catheter's shape was designed to utilize them efficiently. Emphasis was placed on an overbent secondary curve (150-180-degrees) for more precise catheter control. The distal tip of the catheter is 2 cm long in the 4.0 size and the primary bend is shallow, approximately 20%. A 1.5 cm long segment between the secondary and tertiary curves enhances stability and support. Catheter performance was studied during procedures on 90 patients; 89 patients underwent coronary artery angioplasty and one patient underwent diagnostic angiography. The success rate for angioplasty was 95% with no major complications. Mild pressure damping occurred in 18 patients, and mild catheter displacement from the left main coronary artery occurred in 24 patients. Catheter support was judged as excellent to very good in 82 patients. Judkins or Amplatz catheters were not required during this study. The observed disadvantages of the long-tip catheter were the risk of catheter buckling up during advancement into the left main coronary artery and, perhaps, a higher risk of pressure damping. Superselective engagement of the catheter in the left anterior descending or circumflex arteries may be a problem when the left main coronary artery is very short. This study showed the long-tip catheter to be safe and highly successful for angioplasty of the left coronary artery.
引用
收藏
页码:234 / 242
页数:9
相关论文
共 7 条
[1]   MECHANICS OF SELECTIVE CORONARY ARTERY CATHETERIZATION VIA FEMORAL APPROACH [J].
AMPLATZ, K ;
FORMANEK, G ;
STANGER, P ;
WILSON, W .
RADIOLOGY, 1967, 89 (06) :1040-&
[2]  
CARR ML, 1986, CATHETER CARDIO DIAG, V12, P189
[3]   IMPROVED SUCCESS RATE OF PERCUTANEOUS TRANS-LUMINAL GRAFT AND CORONARY ANGIOPLASTY WITH THE EL-GAMAL GUIDING CATHETER [J].
ELGAMAL, MIH ;
BONNIER, JJRM ;
MICHELS, HR ;
VANGELDER, LM .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1985, 11 (01) :89-96
[4]  
JUDKINS MP, 1968, RADIOL CLIN N AM, V6, P467
[5]   LEFT MAIN CORONARY-ARTERY DISEASE PROGRESSION AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
KELLS, CM ;
MILLER, RM ;
HENDERSON, MA ;
LOMNICKI, JM ;
MACDONALD, RG .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 65 (07) :513-514
[6]   PERFORMANCE-CHARACTERISTICS OF A NEW SHAPE OF GUIDING CATHETER FOR PTCA OF THE LEFT CORONARY-ARTERY [J].
NESTO, RW .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1991, 24 (02) :144-148
[7]  
WAYNE VS, 1988, AM J CARDIOL, V61, P450